Equation GMCLIB_SvmStd_Eq11 <strong>and</strong> equation GMCLIB_SvmStd_Eq12 have been<br />

<strong>for</strong>med using the sine rule. These equations can be rearranged <strong>for</strong> the calculation of the<br />

auxiliary time-duration components A <strong>and</strong> B. This is done simply by substitution of the<br />

trigonometric terms sin(30 °), sin(120 °) <strong>and</strong> sin(60 °) by their numerical representations<br />

1/2, √(3)/2 <strong>and</strong> 1/ √(3), respectively.<br />

Equation GMCLIB_SvmStd_Eq13<br />

Equation GMCLIB_SvmStd_Eq14<br />

The resultant duty-cycle ratios, T 120/T <strong>and</strong> T 60/T, are then expressed in terms of the<br />

auxiliary time-duration components defined by equation GMCLIB_SvmStd_Eq13 <strong>and</strong><br />

equation GMCLIB_SvmStd_Eq14, as follows:<br />

Equation GMCLIB_SvmStd_Eq15<br />

Equation GMCLIB_SvmStd_Eq16<br />

With the help of these equations, <strong>and</strong> also considering the normalized magnitudes of the<br />

basic space vectors to be |U 120| = |U 60| = 2/ (3), the equations expressed <strong>for</strong> the unknown<br />

duty-cycle ratios of basic space vectors T 120/T <strong>and</strong> T 60/T can be written:<br />

Equation GMCLIB_SvmStd_Eq17<br />

<strong>Embedded</strong> <strong>Software</strong> <strong>and</strong> <strong>Motor</strong> <strong>Control</strong> <strong>Libraries</strong> <strong>for</strong> <strong>PXS20xx</strong>, Rev. 1.0<br />

Chapter 4 API References<br />

Freescale Semiconductor, Inc. 521