QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Overview<br />
The industry leading <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>) packs up to 3000 watts into a space saving 2U design. Proven<br />
Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy efficient transformerless<br />
design while reducing generated heat.<br />
The <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>UPS</strong> includes a Rack to Tower Conversion Kit for non rack applications outside the data center. In this configuration<br />
the <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> can provide powerful protection to multiple tower servers as well as tower Blade Enclosures such as the <strong>HP</strong><br />
Blade<strong>System</strong> c3000 Enclosure.<br />
In addition, Extended Runtime Modules (ERM) are available to increase battery run time during a power outage. ERMs can be used in<br />
both rack mount and tower configuration with the <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong><strong>UPS</strong>.<br />
Robust and Flexible <strong>UPS</strong> management is provided by <strong>HP</strong>'s New <strong>Power</strong> Protector <strong>UPS</strong> Management software.<br />
R/<strong>T3000</strong> Rackmount <strong>UPS</strong> configuration<br />
1. Front bezel - battery compartment behind bezel 3. <strong>Power</strong> control buttons<br />
2. Status LED indicators<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 1
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Overview<br />
R/<strong>T3000</strong> Tower <strong>UPS</strong> configuration with optional Extended Runtime Module<br />
1. Optional Extended Runtime Module 3. Tower <strong>UPS</strong> floor stands<br />
2. R/<strong>T3000</strong> in Tower <strong>UPS</strong> configuration<br />
Models<br />
<strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> 2U L530 Low Voltage <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> AF466A<br />
<strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> 2U L620 High Voltage <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> AF467A<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 2
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Standard Features<br />
Key Features<br />
New convertible design can be used as a 2U rack mountable <strong>UPS</strong> or as a standalone tower <strong>UPS</strong><br />
Increased power density with up to 3300VA / 3000 Watts (200-240V models)<br />
Greater system uptime with support for up to two Extended Runtime Modules (ERM)<br />
Easy configuration through enhanced front panel display<br />
Enterprise-wide intelligent manageability with bundled power management software<br />
Support for the <strong>HP</strong> <strong>UPS</strong> Network Module that extends the power management capabilities of the <strong>UPS</strong><br />
More efficient voltage regulation using digital signal processing technology<br />
Ultimate long-term battery reliability with <strong>HP</strong> Enhanced Battery Management<br />
Enhanced system flexibility with two independently controlled load segments<br />
Support for Remote Emergency <strong>Power</strong> Off (REPO) circuitry<br />
Easy serviceability through modular design<br />
Hot-Swappable Batteries<br />
Backed by a three year warranty with the first year including parts and labor. <strong>HP</strong>'s Pre-Failure warranty, and a $250,000 load<br />
protection guarantee. (Certain restrictions and exclusions apply)<br />
Optional upgrades include:<br />
Extended Runtime Modules (ERMs)<br />
Management Cards<br />
New Convertible Design The R/<strong>T3000</strong> <strong>G2</strong> can be used in a traditional rack mount environment or converted to a Tower <strong>UPS</strong> to<br />
support powerful Tower servers even Tower Blade Servers such as the <strong>HP</strong> c3000 Blade<strong>System</strong>.<br />
2U <strong>Power</strong> Packed Design Rated near unity at 3300VA / 3000W (200-240V models), the <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> packs more power in<br />
space-conserving rack-mount design, allowing you to support more critical equipment in your rack.<br />
Increase <strong>System</strong> Uptime<br />
with Extended Runtime<br />
Modules<br />
Lower Cost of Ownership<br />
with Innovative<br />
Technology<br />
The Extended Runtime Modules are external battery modules that occupy 2U (3.5 inches) of rack space<br />
each. The <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> supports up to two Extended Runtime Modules (ERM), in either rack mount<br />
or tower configuration, which extend your overall battery runtime.<br />
The <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> utilizes a new industry-leading technology that continually conditions and<br />
regulates power without using the battery, thereby increasing the life of the battery. The output voltage is<br />
automatically regulated, based on the connected load and the input voltage.<br />
Investment Protection <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> incorporates Enhanced Battery Management: an exclusive, patented technology that<br />
with <strong>HP</strong> Enhanced Battery doubles battery service life, optimizes battery recharge time, and provides advance notice of pending<br />
Management<br />
battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive<br />
the best in the industry protection for your critical equipment.<br />
Enhanced Flexibility The high voltage R/<strong>T3000</strong> <strong>UPS</strong> include one PDU Extension Bar. The extension bar has seven C13 outlets for<br />
powering equipment in the rack and attaches to the C19 outlets on the back of the <strong>UPS</strong>. The 6.5 foot (2<br />
meter) cord allows the extension bar to be mounted in many locations inside the rear of the rack.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 3
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Standard Features<br />
Remotely Monitor <strong>UPS</strong>s on The optional <strong>HP</strong> <strong>UPS</strong> <strong>UPS</strong> Module features the ability to perform simultaneous network and out-of-band<br />
the Network<br />
communications. It enables network administrators to remotely monitor <strong>UPS</strong>s and reboot network<br />
devices. It provides SNMP functionality, including power event alerts, network power diagnostics, and<br />
remote <strong>UPS</strong> reboot and testing. Used in conjunction with <strong>HP</strong> <strong>System</strong>s Insight Manager or other SNMP<br />
capable Network Management Software, power-related problems on the network are quickly discovered<br />
and remedied.<br />
Enhanced Front Panel<br />
Display<br />
LED and switch membrane integrated into the front panel with power controls and status and load<br />
indicators for easy visibility.<br />
<strong>HP</strong> R/<strong>T3000</strong> <strong>UPS</strong> Front Panel<br />
1. Dual function LED: Self Test and load indicator (10% load) 7. <strong>Power</strong> on button<br />
2. Dual function LED: Battery fault and Load Indicator (25% load) 8. <strong>Power</strong> off button<br />
3. Dual function LED: Site wiring fault and load indicator (50%<br />
load)<br />
9. Test/Alarm reset button<br />
4. Dual function LED: Over Temperature and load indicator (75%<br />
load)<br />
10. On bypass indicator<br />
5. Dual function LED: Overload and load indicator (100%) 11. On battery indicator<br />
6. Start on battery button 12. Utility power indicator<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 4
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Standard Features<br />
Intelligent Manageability <strong>HP</strong> <strong>Power</strong> Protector management software included with the R1500 <strong>G2</strong> models. The <strong>HP</strong> <strong>Power</strong> Protector<br />
Software enables you to monitor and control an <strong>HP</strong> <strong>UPS</strong> locally or remotely. This software is a versatile,<br />
fully configurable, alert response tool that gives system administrators a full overview of the <strong>UPS</strong>'s<br />
conditions. It enables you to monitor system status and power conditions, configure shut down timing,<br />
customize alert messages, and gracefully shut down servers during an extended power outage. For more<br />
information on <strong>HP</strong> <strong>Power</strong> Protector software please see: www.hp.com/go/hppp<br />
Independently<br />
Controllable Load<br />
Segments<br />
Ease of Maintenance with<br />
Hot-Swappable Batteries<br />
With two independent controlled load segments, you have the flexibility to configure each segment's shut<br />
down schedule to maximize runtime for critical equipment.<br />
The <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> is designed with simple access through the front panel for hot swappable batteries.<br />
Users can safely install new batteries without ever powering down connected server and server options.<br />
<strong>HP</strong> Quality <strong>HP</strong>'s hardware qualification is the toughest in the industry. Extensive evaluation, testing, product<br />
improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical<br />
performance, product quality and compatibility.<br />
Compatibility Compatible with all <strong>HP</strong> servers, storage, racks, rack options, and other rack mountable <strong>HP</strong> equipment (for<br />
PDU options please refer to the <strong>UPS</strong>/PDU compatibility matrix on www.hp.com/products/ups).<br />
Warranty The <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> is covered by a three year warranty, with the first year including parts and labor.<br />
Also, standard on all <strong>HP</strong> <strong>UPS</strong> units, is our exclusive Battery Pre-Failure Warning, which extends the<br />
advantage of a <strong>HP</strong> three-year, limited warranty by applying it to the battery before it actually fails. This<br />
warranty is offered worldwide. Specifically, the Battery Pre-Failure Warning ensures that when customers<br />
receive notification from <strong>HP</strong> <strong>Power</strong> Management Software that the battery may fail, the battery is replaced<br />
free of charge under the warranty.<br />
NOTE: $250,000 Computer/Load Protection Guarantee is also provided, in addition to the <strong>HP</strong> three year,<br />
limited warranty.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 5
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Service and Support<br />
Service and Support <strong>HP</strong> Technology Services<br />
<strong>HP</strong> Technology Services offers you consultants and support experts to solve your most complex<br />
infrastructure problems. We help keep your business running, boost availability and avoid downtime.<br />
Protect your business beyond warranty with <strong>HP</strong> Care Pack Services<br />
When you buy <strong>HP</strong> Options, it's also a good time to think about what level of service you may need. <strong>HP</strong> Care<br />
Pack services provide total care and support expertise with committed response choices designed to meet<br />
your IT and business need.<br />
Recommended <strong>HP</strong> Care Pack Services for optimal satisfaction with your <strong>HP</strong> product<br />
Recommended Services 3-Year <strong>HP</strong> 24x7 4 hour Response, Hardware Support Onsite Service<br />
Provides you with rapid remote support and if required an <strong>HP</strong> authorized representative who will arrive on<br />
site any time and day of the year to begin hardware maintenance service within 4 hours of the service<br />
request being logged.<br />
<strong>HP</strong> ProLiant Server Hardware Installation<br />
Provides for the basic hardware installation of <strong>HP</strong> branded servers, storage devices and networking<br />
options to assist you in bringing your new hardware into operation in a timely and professional manner<br />
Related <strong>HP</strong> Care Pack Services to enhance your <strong>HP</strong> product experience<br />
Related Services 3-Year <strong>HP</strong> 6 hour Hardware Support Onsite Call-to-Repair Service<br />
Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the<br />
system to help return the hardware to operating condition within 6 hours of the initial service request to<br />
the <strong>HP</strong> Global Solution Center<br />
<strong>HP</strong> Proactive Select Service<br />
Provides a flexible way to purchase <strong>HP</strong> best-in-class consultancy and technical services. You can buy<br />
Proactive Select Service Credits when you purchase your hardware and then use the credits over the next<br />
12 months.<br />
Insight Remote Support Delivers secure remote monitoring and support for <strong>HP</strong> servers and storage, 24x7 at no additional<br />
cost. Available as part of <strong>HP</strong> Warranty, Care Pack and Service Contract offers.<br />
Parts and materials <strong>HP</strong> will provide <strong>HP</strong>-supported replacement parts and materials necessary to maintain the covered<br />
hardware product in operating condition, including parts and materials for available and recommended<br />
engineering improvements. Supplies and consumable parts will not be provided as part of this service;<br />
standard warranty terms and conditions apply. Parts and components that have exceeded their maximum<br />
supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating<br />
manual or the technical product data sheet will not be provided, repaired or replaced as part of this service.<br />
Coverage For ProLiant servers and storage systems, this service covers <strong>HP</strong>-branded hardware options qualified for<br />
the server, purchased at the same time or afterward, internal to the enclosure, as well as external<br />
monitors up to 22" and tower <strong>UPS</strong> products; these items will be covered at the same service level and for<br />
the same coverage period as the server unless the maximum supported lifetime and/or the maximum<br />
usage limitation has been exceeded. Coverage of the <strong>UPS</strong> battery is not included; standard warranty terms<br />
and conditions apply.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 6
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Service and Support<br />
The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives<br />
replaced by <strong>HP</strong> due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have<br />
not failed. SSD/Flash Drives that are specified by <strong>HP</strong> as consumable parts and/or that have exceeded<br />
maximum supported lifetime and/or the maximum usage limit as set forth in the manufacturer's operating<br />
manual or the technical data sheet are not eligible for the defective media retention service feature option.<br />
For more information To learn more on services for <strong>HP</strong> ESSN Options, please contact your <strong>HP</strong> sales representative or <strong>HP</strong><br />
Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or<br />
www.hp.com/services/bladesystem<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 7
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Innovative Options to Meet Your Data Center Needs<br />
Optional <strong>UPS</strong> Network<br />
Module<br />
Extended Runtime Module<br />
(ERM)<br />
Rack to Tower Conversion<br />
Kit<br />
The <strong>HP</strong> <strong>UPS</strong> Network Module enables you to monitor and manage power environments through<br />
comprehensive control of <strong>HP</strong> <strong>UPS</strong>s. The <strong>HP</strong> <strong>UPS</strong> Management Module can support either a single <strong>UPS</strong><br />
configuration or provide additional power protection with support for dual redundant <strong>UPS</strong> configuration for<br />
no-single-point-of-failure. The additional serial ports will provide greater power management control and<br />
flexible monitoring.<br />
The management module can be configured to send alert traps to <strong>HP</strong> <strong>System</strong>s Insight Manager and other<br />
SNMP management programs or used as a standalone management system. This flexibility enables you to<br />
monitor and manage <strong>UPS</strong>s through the network. To facilitate day-to-day maintenance tasks, the<br />
embedded management software provides detailed system logs.<br />
The <strong>HP</strong> <strong>UPS</strong> Network Module provides remote management of a <strong>UPS</strong> by connecting the <strong>UPS</strong> directly to the<br />
network. Configuration & Management of the <strong>UPS</strong> from anywhere and at anytime via a standard web<br />
browser.<br />
NOTE: For more information on the <strong>UPS</strong> Network Module please see: www.hp.com/go/hpunm.<br />
The <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong> supports up to two Extended Runtime Modules. Each module is a 2U (3.5 inches), rack<br />
mountable battery module that extends your overall battery runtime.<br />
The included <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>UPS</strong> Tower Conversion Kit allows you to use the powerful R/<strong>T3000</strong> <strong>G2</strong> in a<br />
tower configuration for your most powerful tower Servers or Blade Enclosures. The kit contains stabilizing<br />
feet and appropriate hardware for a fast, easy form factor change. Each Tower Conversion Kit can support<br />
one <strong>UPS</strong> and up to two Extended Runtime Modules.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 8
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Related Options<br />
Extended Runtime Module <strong>HP</strong> R/<strong>T3000</strong> Extended Runtime Module AF455A<br />
<strong>UPS</strong> Management <strong>HP</strong> <strong>UPS</strong> Network Module AF465A<br />
<strong>HP</strong> Care Pack <strong>HP</strong> Install Universal <strong>Power</strong> Supply 3KVA to Below 6KVA Service U4693E<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 9
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Model Matrix<br />
<strong>UPS</strong> Models<br />
Part Number Operating<br />
Voltage Settings<br />
AF466A<br />
Low Voltage<br />
AF467A<br />
High Voltage<br />
100, 110, 120,<br />
127<br />
200/2081 ,<br />
Actual output<br />
voltage 204VAC<br />
<strong>Power</strong> Out Input Connection Output Connection<br />
(VA/Watts)<br />
2880/2700 L5-30P, 3m cord LS12 : 2x NEMA 5-20 outlets, 1 x NEMA L5-30R<br />
LS23 : 2x NEMA 5-20 outlets<br />
3300/3000 L6-20P, 3m cord LS12 : 3x IEC C13, 1x IEC C-19, 1x NEMA L6-20R<br />
LS23 : 3x IEC C13, 1x IEC C-19<br />
NOTE: Includes one PDU Extension Bar. Each<br />
Extension Bar has 7x C13 outlets and plugs into a<br />
C-19 on the rear of the <strong>UPS</strong>.<br />
1 Factory default setting.<br />
2 LS1 = Load Segment 1<br />
3 LS2 = Load Segment 2<br />
Kit Contents <strong>HP</strong> <strong>UPS</strong> R/<strong>T3000</strong> <strong>G2</strong><br />
<strong>Power</strong> Products Documentation CD<br />
Depth adjustable fixed rack mounting rails, mounting brackets, cord retention clips<br />
Rack to Tower Conversion Kit and floor stand<br />
Communications cables<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 10
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Estimated Backup Times Chart (Minutes)<br />
Low Voltage model<br />
(2880VA / 2700 Watt)<br />
Load (Percent*) Estimates battery runtime<br />
(Minutes)<br />
With One Extended Runtime<br />
Module (Minutes)<br />
With Two Extended Runtime<br />
Modules (Minutes)<br />
540W (20%) 45 142 256<br />
1350W (50%) 15 55 99<br />
2160W (80%) 7 34 60<br />
2700W (100%) 5 26 47<br />
NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.<br />
High Voltage model<br />
(3300VA / 3000 Watt)<br />
Load (Percent*) Estimated battery runtime<br />
(Minutes)<br />
With One Extended Runtime<br />
Module (Minutes)<br />
With Two Extended Runtime<br />
Modules (Minutes)<br />
600W (20%) 40 125 225<br />
1500W (50%) 12 50 99<br />
2400W (80%) 6 30 60<br />
3000W (100%) 4 24 47<br />
NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 11
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Technical Specifications<br />
Unit Dimensions (HxWxD) 3.5 x 17.5 x 25 inches / 8.9 x 44.5 x 63.5 cm<br />
Shipping Dimensions 11.25 x 23.48 x 36.25 inches / 28.57 x 59.64 x 92.07 cm<br />
Unit Weight 82 lbs/37 kg<br />
Shipping Weight 89 lbs <strong>UPS</strong> and 127 lbs ERM / 40.37 kg & 57.6 kg<br />
BTU Break Down BTU On Line 540 BT/hr<br />
BTU On Battery 1138 BTU/hr<br />
Battery Type 12 V, 5 AH, sealed, maintenance-free, rechargeable, valve regulated lead-acid<br />
batteries with a 3-5 year service life at 25C (77F).<br />
Electrical Input Voltage Range See Model Matrix for nominal and user selectable voltage settings<br />
Frequency 50/60 Hz<br />
Online Efficiency 95%<br />
REPO Remote Emergency <strong>Power</strong>-Off disables AC power to load<br />
Online Regulation -10% to +6% of nominal voltage<br />
Electrical Output On battery Regulation ±5% of nominal voltage<br />
Voltage Wave Form Sine wave<br />
Connections See Model Selection Matrix; divided into 2 Load Segments<br />
Output Protection Re-settable circuit protectors<br />
Type Maintenance-free, sealed, valve-regulated lead acid (VRLA)<br />
Battery Extended Batteries Up to two ERMs supported<br />
Backup Time See Backup Times Chart<br />
Recharge Time
QuickSpecs <strong>HP</strong> R/<strong>T3000</strong> <strong>G2</strong> <strong>Uninterruptible</strong> <strong>Power</strong> <strong>System</strong> (<strong>UPS</strong>)<br />
Technical Specifications<br />
Environment-friendly<br />
Products and Approach<br />
End-of-life Management<br />
and Recycling<br />
© Copyright 2013 Hewlett-Packard Development Company, L.P.<br />
The information contained herein is subject to change without notice.<br />
Hewlett-Packard offers end-of-life <strong>HP</strong> product return, trade-in, and recycling<br />
programs in many geographic areas. For trade-in information, please go to:<br />
http://www.hp.com/go/green. To recycle your product, please go to:<br />
http://www.hp.com/go/green or contact your nearest <strong>HP</strong> sales office.<br />
Products returned to <strong>HP</strong> will be recycled, recovered or disposed of in a<br />
responsible manner.<br />
The EU WEEE directive (2002/95/EC) requires manufacturers to provide<br />
treatment information for each product type for use by treatment facilities.<br />
This information (product disassembly instructions) is posted on the Hewlett<br />
Packard web site at: http://www.hp.com/go/green. These instructions may be<br />
used by recyclers and other WEEE treatment facilities as well as <strong>HP</strong> OEM<br />
customers who integrate and re-sell <strong>HP</strong> equipment.<br />
The only warranties for <strong>HP</strong> products and services are set forth in the express warranty statements accompanying such products and<br />
services. Nothing herein should be construed as constituting an additional warranty. <strong>HP</strong> shall not be liable for technical or editorial<br />
errors or omissions contained herein.<br />
DA - 14058 North America — Version 6 — February 8, 2013 Page 13