Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 1 of 6<br />

1. Preparation and Company Name:<br />

2.<br />

3.<br />

4.<br />

Preparation: (“Lonsealer”)<br />

Group I: PVC-Cold Welding Liquid (Type A), PVC-Cold Welding Paste (Type C), PVC-Seal Cold<br />

Welding Fluid, PVC-Seal Paste (Use: Welding of PVC-Floor- and Wall Coverings, PVC Foils<br />

and other PVC Materials).<br />

Group II: Cleansing-Container, Refill Fluid for Cleansing-Container (Use: Cleaning of nozzles of the<br />

applicators)<br />

All preparations show almost identical physical-chemical, safety technical, toxic, and ecological properties.<br />

The groups I and II differ in point 2 (composition / specifications of components), point 10 (stability and<br />

reactivity) and point 14 (transport information).<br />

Name of Company (Manufacturer): Werner Müller GmbH, Rudolf-Diesel-Str. 7, D-67227 Frankenthal<br />

Phone: +49–(0) 6233-3793-0; Fax: +49(0) 6233-3793-20 Point of Contact: Mr. Pisek<br />

Name of Company (Distributor): Lonseal, <strong>Inc</strong>., 928 E. 238 th St., Carson, CA 90745<br />

USA Emergency Phone: (800) 535-5053 INFOTRAC<br />

Composition / Information On Ingredients:<br />

Preparations I contain:<br />

Tetrahydrofuran (stabilized) >80 wt. %<br />

CAS-No.: 109-99-9 EG-No.: 203-726-8 Index-No. 603-025-00-0<br />

F highly flammable, Xi irritant, R11, R19, R36/37 (see point 15)<br />

PVC (Polyvinyl chloride) >5 wt.%, compounded, with softening agent, no danger substance corresponding to<br />

the Danger-Substance-Regulations.<br />

Preparations II contain:<br />

Tetrahydrofuran (stabilized) >95 wt. %<br />

CAS-Nr.: 109-99-9 EG-Nr.: 203-726-8 Index-Nr.: 603-025-00-0<br />

F highly flammable, Xi irritant, R11, R19, R36/37 (see point 15)<br />

Main Hazards<br />

Indications of danger for dangerous substances and preparations:<br />

Highly flammable.<br />

May form explosive peroxides.<br />

Irritating to eyes and skin.<br />

First Aid Measures<br />

General Advice:<br />

Immediately remove contaminated clothing. If danger of loss of consciousness, place patient in recovery<br />

position and transport accordingly. Apply artificial respiration if necessary. Helpers pay attention to your own<br />

safety.<br />

Inhalation: keep patient calm, remove to fresh air, and summon medical help.<br />

Skin contact: Immediately wash thoroughly with soap and water, consult a skin specialist.<br />

Eye contact: Immediately wash affected eyes under running water with eyelids held open, consult an eye<br />

specialist.<br />

Ingestion: Rinse mouth immediately and then drink plenty of water, summon medical help.<br />

UN-2056<br />

TETRAHYDROFURAN<br />

FLAMMABLE LIQUID


Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 2 of 6<br />

5.<br />

6.<br />

7.<br />

8.<br />

Fire Fighting Measures:<br />

Suitable extinguishing media: Water, dry powder, foam, carbon dioxide (CO2).<br />

Special protective equipment: In case of fire, use a self-contained breathing apparatus.<br />

Further information: Collect contaminated extinguishing water separately. Do not allow to reach drains. If<br />

product is involved in fire, keep containers cool by spraying with water.<br />

Accidental Release Measures:<br />

Personal precautions: Do not breath in vapors. Secure sufficient ventilation. Keep away from sources of<br />

ignition.<br />

Environmental precautions: Do not allow to reach sewerage, surface- and underground water as well as<br />

ground.<br />

Methods for cleaning up: Absorb small amounts with absorbent material and dispose correctly. Larger spills<br />

should be dammed-off and pumped into containers; (Pay attention to explosive atmosphere); Soak up<br />

remainder with absorbent material and dispose of in accordance with local regulations (see point 13).<br />

Handling and Storage:<br />

Handling:<br />

Protection against fire and explosion: Ensure thorough ventilation of storage and work areas.<br />

Protection against electrostatic charge – sources of ignition should be kept clear – fire extinguishers should<br />

be kept handy.<br />

Storage:<br />

Prevent contact with air / oxygen (formation of peroxide).<br />

For storage, do not use containers made of PVC.<br />

Storage class 3A: Flammable <strong>liquid</strong> substances (concept of the German Association of Chemical Industry)<br />

Exposure Controls and Personal Protection:<br />

Limiting Value of Exposition (Germany):<br />

Threshold Limit Value of the air at the workplace: (TRGS 900)<br />

Tetrahydrofuran CAS -No. 109-99-9<br />

MAK: 50 ml/m 3 150 mg/m 3<br />

Biological tolerance threshold at the workplace:<br />

Threshold value (BAT): 8 mg/l<br />

Time of sampling: End of exposition, resp. end of shift<br />

Substance for check-up: Urine.<br />

Limits and monitoring of the exposition:<br />

For above-mentioned preparations, measurements were taken at the workplace in cooperation with the<br />

mutual indemnity associations of the construction industry to determine the exposition of the Werner Müller<br />

PVC-Cold Welding Liquids and-Pastes during workmanship. The entire description of the exposition has been<br />

published in the “Handbuch Bauchemikalien” (Construction Chemicals’ Handbook) (22 nd supplement 03/2002)<br />

which is published by the mutual indemnity associations of the construction industry (edited by Dr. Reinhold<br />

Rühl, Norbert Kluger) and available at the Ecomed-Verlag (Publishers), Landsberg am Lech (Germany).<br />

11 measurements were less than half the threshold value, only one of the measurements revealed exposure<br />

in excess of the threshold value. In total, the measurements taken prove according to TRGS 402 (Monitoring


Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 3 of 6<br />

9.<br />

and Assessment of the Concentration of Hazardous Substances in the Air at Workplaces) appendix 1 that the<br />

threshold value for tetrahydrofuran is not exceeded when Werner Müller PVC Cold Welding Liquids and<br />

Pastes are used.<br />

Measurements Average 95 percentile Minimum Maximum<br />

Tetrahydrofuran 17 72.6 mg/m³ 136.8 mg/m³ 7.0 mg/m³ 213.0 mg/m³<br />

Based on the results given it is not necessary to take any further measurements of exposure in<br />

companies and on building sites where Werner Müller PVC Cold Welding Liquids and Pastes are<br />

used! The threshold value of tetrahydrofuran and the peak limit factor are not exceeded.<br />

Respiratory protective measures are not necessary.<br />

Personal protective equipment:<br />

Respiratory protective measures: Not necessary.<br />

Hand protection: Chemical Protection Gloves out of nitrile-butadien-rubber with a minimum thickness of 0.4<br />

mm are suitable to be used for splash protection. Latest 5 minutes after contamination with the chemical, take<br />

off the skin protection and reject.<br />

Suitable Products are for example: Comatril from the company Comasec Phone: +49-(0) 6821-8608-0 or<br />

Protection of the body: closed working clothes.<br />

Camatril from the company KCL Phone: +49-(0) 6659-87-0<br />

General safety and hygiene measures: Usual Safety Precautions for the handling of chemicals are to be<br />

observed. Avoid contact with skin, eyes, clothing, and the inhaling of vapors.<br />

Physical and Chemical Properties:<br />

Form: <strong>liquid</strong> to paste like<br />

Color: various<br />

Odor: ethereal<br />

Change in physical state:<br />

Melting point / Melting range:<br />

-108 °C<br />

Boiling point / Boiling range: 65,5 °C – 66,5 °C<br />

Flash point: -21,5 °C (DIN 51 755)<br />

Explosion limits:<br />

lower: 1,5 Vol.%<br />

upper:<br />

12,0 Vol.%<br />

Ignition temperature:<br />

Vapor pressure: 200 mbar (20°C)<br />

Density: 0.8892 g/cm 3<br />

215 °C (DIN 51 794)<br />

Solubility in water: (20°C) partially miscible<br />

Solubility in other solvents: miscible with many organic solvents.<br />

pH-value: (at 200g/l, 20°C) 7 – 8.<br />

Partition coefficient: n-Octanol/Water (log Pow): 0,45.


Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 4 of 6<br />

10.<br />

11.<br />

12.<br />

Viscosity: 0,5-2045 mPa s<br />

Stability and reactivity:<br />

Conditions/Substances to be avoided:<br />

Minimize exposure to oxygen/air.<br />

Minimize exposure to light.<br />

Hazardous reactions:<br />

Development of peroxides.<br />

Hazardous decomposition products:<br />

Group I: Peroxides, in case of fire: Hydrogen chloride (HCL)<br />

Groudp II: Peroxides<br />

Toxicological Information:<br />

Acute toxicity:<br />

LD50 / oral / rat: 4.400 mg / kg.<br />

LC50 / inhal. / rat: 55-60 mg/l / 4 h.<br />

Primary skin irritation / rabbit / BASF-test: irritant.<br />

Primary mucous membrane irritation / rabbit's eye / BASF-test: irritant.<br />

Acute inhalation hazard (rat; test result depending on toxicity and volatility): No mortality after 10 min.<br />

exposure in a highly enriched and / or saturated atmosphere at ambient temperatures. Mortality after longer<br />

exposure.<br />

Other information:<br />

Ames-test: no mutagenic effect<br />

Additional information:<br />

High concentrations have a narcotizing effect. Skin resorption hazard.<br />

Ecological information:<br />

Elimination information<br />

Test method: OECD 301F / ISO 9408.<br />

Method of analysis: BSB of the ThSB.<br />

Degree of elimination: > 80 %.<br />

Evaluation: biodegradable.<br />

The product is highly volatile and can be eliminated from water by stripping.<br />

Behavior and environmental fate:<br />

Inhibition of degradation activity in activated sludge is not to be anticipated during correct introduction of low<br />

concentrations.<br />

Ecotoxic affects:<br />

Toxicity to fish: LC 50 / Pimephales promelas<br />

2160 mg/l / 96h<br />

Toxicity to daphnae (acute): EC/LC 50 (24h)<br />

Toxicity to algae EC/LC50 (192h)<br />

Toxicity to bacteri a: EC/LC50 (16h)<br />

5930 mg/l<br />

> 3700 mg/l<br />

> 580 mg/l


Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 5 of 6<br />

13.<br />

14<br />

Further ecological information:<br />

CSB-value: 1572 mg/g<br />

The product should not be allowed to find its way into inshore waters without pretreatment (biological sewage<br />

treatment plant).<br />

Considerations for Disposal:<br />

Not dried out residues must be disposed of by special means, e.g. suitable incineration, in accordance with<br />

local regulations.<br />

Disposal code no. Kind of waste<br />

08 04 06 Adhesives and sealing compounds which do not contain any<br />

halogeneted solvents<br />

Contaminated packaging:<br />

Contaminated packaging should be optimally emptied; they can then be passed on for recycling after being<br />

thoroughly cleaned.<br />

Transport Information<br />

Preparation:<br />

UN-Number:<br />

Class:<br />

Packing Group:<br />

Transport by Land<br />

Navigation<br />

ADR/RID<br />

Proper Shipping<br />

Name:<br />

Group É 1133 3 II Klebstoffe (enthält<br />

Tetrahydrofuran)<br />

Sondervorschrift<br />

640 (D)<br />

Group ÉÉ<br />

2056<br />

Transport by Airfreight<br />

ICAO/IATA<br />

Proper Shipping<br />

Name:<br />

Adhesives<br />

containing<br />

flammable<br />

<strong>liquid</strong><br />

3 II Tetrahydrofuran Tetrahydrofuran<br />

Packing<br />

Instructions<br />

(Cargo)<br />

Packing<br />

Instructions<br />

(Passenger)<br />

305<br />

307<br />

Transport by Ocean<br />

Freight IMDG / GGVSee<br />

Proper Shipping<br />

Name:<br />

Adhesives<br />

containing<br />

flammable<br />

<strong>liquid</strong><br />

305 307 Tetrahydrofuran<br />

3-05<br />

3-06<br />

EmS-Number


Werner Müller GmbH<br />

-PVC-Cold-Welding Liquid-<br />

EG-Safety data sheet (group material safety data sheet)<br />

According to 91/155/EWG<br />

Date revised: 14.05.2002 Version 07WM<br />

Printing Date: 6/3/02 Page 6 of 6<br />

1515. Labeling in according to EEC Directives<br />

The substance should be labeled as follows in according to EEC "Hazardous Substances" Directive:<br />

16.<br />

Index-No. 603-205-00-0<br />

F Highly flammable<br />

Xi Irritant<br />

R11 Highly flammable<br />

R19 May form explosive peroxides.<br />

R36/37 Irritating to eyes and skin.<br />

S 2 Keep out of the reach of children.<br />

S16 Keep away from sources of ignition – no smoking.<br />

S29 Do not empty into drains.<br />

S33 Take precautionary measures against static discharges.<br />

National legislation / regulations<br />

TRGS 900 (Germany): For Explanation see TRGS 901 Nr. 91 (Germany)<br />

Classification in according to VbF (Germany): B<br />

TA Luft (Germany): Class II, Number 3.1.7<br />

Water hazard class (Germany): WGK 1<br />

Other Information:<br />

Leaflet of the professional association M 038 (Germany)<br />

The information contained herein is based on the present state of our knowledge and does not therefore<br />

guarantee certain properties. Recipients of our product must take responsibility for observing existing laws<br />

and regulations.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!