BRUSA / 11.2012 / <strong>PDU254</strong><br />
Specifications <strong>PDU254</strong><br />
Electrical data <strong>PDU254</strong><br />
Operating voltage 200 - 500 V<br />
Max. switching current of contactors 6 A<br />
Voltage for control signals (Pin = high) 7 - 15 V<br />
Interlock current 10 mA<br />
Voltage for interlock generator - 48 V<br />
Allowed voltage drop over interlock loop max. 30 V<br />
Resistance value of discharge resistor (PTC) 33 Ohm<br />
Recommended cable cross - section for main connection 300 A and cascading 50 mm2 Recommended cable cross - section for Range - Extender or DC - fast charge 25 mm2 Recommended cable cross - section for small electric consumers (up to 24 A) 4 mm2 Performance data at + 25°C <strong>PDU254</strong><br />
Allowed peak current for max. duration 10 s 400 A<br />
Continuous current: BATT - connection 1 + 2 to DMC - connection 1 + 2 300 A<br />
Continuous current: BATT - connection 1 + 2 to RXT - connection 100 A<br />
Continuous current: BATT - connection 1 + 2 to NLG - / BSC - / AUX - connection 20 A<br />
Mechanical data <strong>PDU254</strong><br />
Material AlMgSi1 ---<br />
Housing volume 4.16 l<br />
System weight (incl. fuses) 3.9 kg<br />
Weight fuse 300 A 200 g<br />
Weight fuse 100 A 90 g<br />
Weight fuse 20 A 10 g<br />
IP - protection IP68 ---<br />
Waterproof pressure equalizing membrane yes ---<br />
Thermal <strong>PDU254</strong><br />
Ambient temperature min. - 40 °C<br />
Ambient temperature max. + 85 °C<br />
Schema<br />
www.brusa.biz<br />
BRUSA <strong>Elektronik</strong> <strong>AG</strong><br />
Neudorf 14<br />
CH-9466 Sennwald<br />
+41 81 758 19 00<br />
info@brusa.biz