UV Disinfection Systems<br />

<strong>Spektron</strong> Series<br />

Main applications:<br />

Drinking water,<br />

Industrial process water<br />

for food and beverages<br />

DIN EN ISO 9001<br />

DIN EN ISO 14001


No Chance for Harmful Microorganisms<br />

Guanine Cytosine<br />

Guanine Cytosine<br />

X-rays<br />

Vacuum-<br />

UV<br />

Adenine Thymine<br />

Adenine Thymine<br />

Cytosine<br />

Guanine<br />

Cytosine<br />

Guanine<br />

Adenine Thymine<br />

Adenine Thymine<br />

Ultraviolet Visible light Infrared<br />

UV-C UV- UV-A<br />

B<br />

100 200 280 315 400 780<br />

UV Spektrotherm<br />

lamp (254 nm)<br />

UV light<br />

UV-light inactivates micro-organisms by damaging the hereditary DNA/RNA,<br />

thereby hindering vital cell division processes.<br />

Inactivation of<br />

microorganisms<br />

Wavelength (nm)<br />

UV is a high-energy light with a wavelength of 100-400nm. The UV-C<br />

spectrum with a wavelength of approx. 250 nm to 260 nm is particularly<br />

effective for disinfection.<br />

Thymine<br />

Adenine<br />

Thymine<br />

Adenine<br />

Thymine<br />

Thymine<br />

Dimer<br />

Adenine<br />

Adenine<br />

Cytosine<br />

Guanine<br />

Cytosine<br />

Guanine<br />

Adenine Thymine<br />

Adenine Thymine<br />

Safe disinfection<br />

at 254 nm<br />

UV disinfection has been proven<br />

worldwide as the most important water<br />

disinfection process. Bacteria, viruses,<br />

yeast and parasites (for example,<br />

cryptosporidium and giardia) are<br />

effectively inactivated by using UV light.<br />

There is no development of resistance<br />

in UV disinfection as is increasingly<br />

experienced in, for example, treatment<br />

using antibiotics and also in<br />

chlorination. There are no resultant<br />

dangerous by-products (DBP) as is the<br />

case with chemical disinfection.<br />

Legionella pneumophila – WEDECO UV<br />

protects against these extremely resistant<br />

bacteria without creating any harmful biproducts<br />

Comparison of UV, chlorine and chlorine dioxide disinfection processes<br />

Type Use in Pathogen Virus Cryptosporidium Possible harmful<br />

organically burdened bacteria by-products<br />

waters (Humic substances)<br />

UV disinfection<br />

with low pressure ++ ++ + ++ none<br />

Chlorine - + + - THM,<br />

AOX, Chlorite<br />

Chlorine dioxide -- ++ + + Chlorite (THM)<br />

++ = very effective + = effective • = less effective - = barely effective -- = not applicable


<strong>Spektron</strong> System Components<br />

PECO – menu controlled PLC<br />

Lamp connection<br />

Spring<br />

Outflow<br />

Cleaning, deaeration valve<br />

Installation site at waterworks<br />

Filter backflush<br />

UV<br />

Treatment Increase<br />

of pressure<br />

The long-term stable<br />

and certified UV sensor<br />

is an extremely precise<br />

monitoring tool<br />

Certified UV sensor<br />

UV<br />

Elevated tank<br />

Supply network<br />

type TDS<br />

Spektrotherm ®<br />

UV Lamp<br />

UV Digital controlled electronic ballasts<br />

Source<br />

Cleaning, deaeration valve<br />

CrossMix ®<br />

flow control<br />

Inflow


WEDECO Spektrotherm ® UV Lamps<br />

The most advantageous solution when compared to medium pressure lamps<br />

EIGENSCHAFTEN<br />

• Significantly higher efficiency in UV-C:<br />

VORTEILE<br />

Spektrotherm ® Lamp: 40 % efficient • Medium pressure lamp: 12-15 % efficient<br />

• Lower electricity and operating costs • Essential higher electricity and operating costs<br />

• Fewer lamps • Shorter lifespan of lamps<br />

• Lower lamp operating temperature: • Medium pressure lamp: 800 °C<br />

Spektrotherm ® Lamp: 100 °C • Medium pressure requires cooling at zero-flow<br />

• Low lamp aging and longer service life • Medium pressure requires reactor<br />

reduce operating costs temperature monitoring<br />

• Significantly less scaling on the • Medium pressure lamps require a<br />

protective quartz sleeves mechanical wiping system<br />

• Immediate re-start possible • Medium pressure lamps must cool down for 10 minutes<br />

• Amount of liquid mercury: • Amount of liquid mercury:<br />

Spektrotherm ® lamp: 0 mg<br />

• Environmentally-friendly<br />

• Spektrotherm<br />

Medium pressure lamp: up to 300 mg<br />

® lamps are recycled by<br />

WEDECO free of charge<br />

Emission spectra [wavelengths in nm]<br />

Relative UV emission (%)<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

254 nm<br />

200<br />

Spectral curve of<br />

cell inactivation<br />

250 300 350 400 450 500 550 600<br />

100<br />

The WEDECO Spektrotherm ® lamp emits almost entirely at a<br />

wavelength of 254nm, which lies in the maximum spectrum<br />

range for effective disinfection<br />

100%<br />

80%<br />

60%<br />

40%<br />

20%<br />

0%<br />

WEDECO<br />

<strong>Spektron</strong><br />

LOW PRESSURE MEDIUM PRESSURE<br />

169%<br />

Medium<br />

Pressure<br />

Energy costs<br />

Maintenance<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Lamp costs /<br />

Quarz tube costs<br />

Investment costs<br />

Lifespan cost analysis based on 10 years.<br />

DNA absorbtion (%)<br />

Relative UV emission (%)<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

200<br />

Spectral curve of<br />

cell inactivation<br />

250 300 350 400 450 500 550 600<br />

100<br />

The medium pressure lamp emits a broad-brand spectrum<br />

that for the most part lies outside the spectrum range<br />

relevant to disinfection<br />

Taking photo reactivation into<br />

account = safe disinfection<br />

Photo reactivation, meaning the self-repair of inactivated microorganisms,<br />

can occur with many microorganisms making it<br />

particularly important to consider this effect in the original<br />

equipment design. This is done by choosing a safe UV dosage<br />

(400 J/m 2 =40mJ/cm 2 =40.000 µWs/cm 2 ) that is confirmed by<br />

microbiological tests (according to DVGW W-294 and/or Ö-Norm<br />

M-5873-1). Leading UV specialists have repeatedly ascertained<br />

that there is no difference in the safety of the disinfection<br />

capabilities between low and medium pressure lamps when this<br />

UV dose is applied.<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

DNA absorbtion (%)


UV Disinfection Systems<br />

<strong>Spektron</strong> Series<br />

The biodosimetrically tested UV systems from the <strong>Spektron</strong> product<br />

range meet all the requirements of safe and environmentally friendly<br />

water disinfection according to §11 of the German drinking water<br />

regulation (TrinkwV 2001). The <strong>Spektron</strong> units are certified according<br />

to Austrian ÖNORM (M 5873-1) and German DVGW (W 294-2)<br />

directives. An European-wide CEN standard is in preparation.<br />

The new <strong>Spektron</strong> range offers a wide array of uses from domestic<br />

water supply to industrial uses to large water plants with a capacity<br />

of more than one thousand m 3 /h. What makes them special is their<br />

consistent optimisation of hydraulic characteristics with the use of<br />

the unique CrossMix ® module. Electronic ballasts of the newest<br />

generation in conjunction with our Spektrotherm ® lamp<br />

technology allows minimising energy and lamp costs by up to 30%.<br />

Improved Spektrotherm ® lamps offer today even better efficiency<br />

and a very long lamp life.<br />

The robust construction makes them certifiably usable in waters with<br />

high humic contents or in environments with increased requirements<br />

in terms of EMC protection. The new uv reactor construction ensures<br />

simple installation within virtually any space limitation.<br />

ADVANTAGES<br />

• Safe disinfection through<br />

biodosimetrically certified<br />

systems<br />

• No harmful by-products<br />

(such as THM’s in chlorinating)<br />

• Exceptionally low operating costs<br />

through uniquely efficient<br />

electricity flow and electronic<br />

units of the newest generation<br />

• Excellent EMC protection, exceeds<br />

valid industry and household<br />

standards<br />

• Ongoing self-monitoring of UV<br />

intensity, reactor temperatures<br />

and water flow combined with a<br />

high-performance memory and<br />

analysis system<br />

• Extremely low loss of pressure<br />

• Variable installation positions for<br />

easy integration into existing<br />

pipeline systems


C O N T A C T S<br />

AUSTRALIA / SOUTH-EAST ASIA<br />

WEDECO Pty. Ltd.<br />

Unit 31, Slough Estate<br />

Holker Street<br />

Silverwater NSW 2128<br />

Australia<br />

Tel.: +61 2 9751 7500<br />

Fax: +61 2 9751 7511<br />

E-mail: wedeco.au@itt.com<br />

AUSTRIA<br />

WEDECO VISA Water Technology GmbH<br />

Seyrlstrasse 2<br />

A-4863 Seewalchen am Attersee<br />

Tel.: +43 7662 5626-0<br />

Fax: +43 7662 5626-20<br />

E-mail: wedeco.at@itt.com<br />

CHINA<br />

WEDECO<br />

c/o ITT<br />

31 Floor, Tower A<br />

Hongqiao City Center<br />

No. 100 Zunyi Road<br />

Shanghai, 200051<br />

Tel.: +86 21 2208 2888<br />

Fax: +86 21 2208 2999<br />

E-mail: wedeco.cn@itt.com<br />

FRANCE<br />

WEDECO France S.A.S.<br />

29-31 boulevard de la Muette<br />

F-95145 Garges-lès-Gonesse Cedex<br />

Tel.: +33 1 34534500<br />

Fax: +33 1 34530196<br />

E-mail: wedeco.fr@itt.com<br />

Internet: www.wedeco.com<br />

GERMANY<br />

WEDECO AG<br />

Boschstr. 4<br />

D-32051 Herford<br />

Tel.: +49 5221 930 0<br />

Fax: +49 5221 930 222<br />

E-mail: wedeco.de@itt.com<br />

WEDECO GmbH<br />

Boschstr. 6<br />

D-32051 Herford<br />

Tel.: +49 5221 930 0<br />

Fax: +49 5221 930 222<br />

E-mail: wedeco.de@itt.com<br />

GREAT BRITAIN<br />

WEDECO Ltd.<br />

Unit 7, Mercury Park<br />

Mercury Way<br />

Urmston<br />

GB-Manchester M41 7LY<br />

Tel.: +44 16 1865 5000<br />

Fax: +44 16 1865 5500<br />

E-mail: wedeco.uk@itt.com<br />

ITALY<br />

WEDECO SRL<br />

Via Tridente, 22<br />

I-70125 Bari<br />

Tel.: +39 080 5910511<br />

Fax: +39 080 5910514<br />

E-mail: wedeco.it@itt.com<br />

This brochure was submitted by:<br />

KOREA<br />

WEDECO Co., Ltd.<br />

Rm# 1017, Doosan Venture Digm Bldg.<br />

126-1, Pyeongchon-Dong, Dongan-Gu<br />

Anyang-Si, Kyeonggi-Do<br />

Korea 431-070<br />

Tel.: +82 31 478 5577<br />

Fax: +82 31 478 5588<br />

E-mail: wedeco.kr@itt.com<br />

NETHERLANDS<br />

WEDECO B.V.<br />

Steenovenweg 5<br />

NL-5708 HN Helmond<br />

Tel.: +31 492 472464<br />

Fax: +31 492 472635<br />

E-mail: wedeco.nl@itt.com<br />

NEW ZEALAND<br />

WEDECO Ltd.<br />

P. O. Box 101-303<br />

NSMC<br />

Auckland 1310<br />

New Zealand<br />

Tel.: +64 9 448 21 24<br />

Fax: +64 9 448 21 25<br />

E-mail: wedeco.nz@itt.com<br />

NORTH AMERICA<br />

WEDECO, Inc.<br />

14125 South Bridge Circle<br />

Charlotte, North Carolina 28273 USA<br />

Tel.: +1 704 7167600<br />

Fax: +1 704 7167601<br />

E-mail: municipaluv@itt.com<br />

municipalozone@itt.com<br />

No information and/or data contained in this publication shall be construed to create any liability<br />

on the part of WEDECO AG. Any new issue of this publication shall automatically invalidate<br />

and supersede any and all previous issues. Product availability, prices and delivery dates are<br />

exclusively subject to our respective order confirmation form; the same applies to orders based<br />

on development samples delivered. This publication is not to be construed as an offer. It is<br />

intended merely as an invitation to make an offer. By this publication, WEDECO AG does not<br />

assume responsibility or any liability for any patent infringements or other rights of third<br />

parties which may result from its use. Reprinting this publication is generally permitted, indicating<br />

the source. However, our prior consent must be obtained in all cases.<br />

© WEDECO AG 2007<br />

POLAND<br />

WEDECO sp. z. o. o.<br />

ul. Polna 1b<br />

PL-62-025 Kostrzyn Wlkp.<br />

Tel.: +48 61 8970 660<br />

Fax: +48 61 8970 661<br />

E-mail: wedeco.pl@itt.com<br />

SPAIN<br />

WEDECO Rex S.A.<br />

Calle Isla de la Palma 32<br />

Nave 6, Polígono Ind. Norte<br />

San Sebastian de los Reyes<br />

E-28700 Madrid<br />

Tel.: +34 91 659 1800<br />

Fax: +34 91 659 1801<br />

E-mail: wedeco.es@itt.com<br />

SWITZERLAND<br />

WEDECO GmbH<br />

Birkenweg 4<br />

CH-8304 Wallisellen<br />

Tel.: +41 43 355 7010<br />

Fax: +41 43 355 7011<br />

E-mail: wedeco.ch@itt.com<br />

UNITED ARAB EMIRATES<br />

WEDECO<br />

c/o ITT<br />

Twin Towers<br />

P.O. Box 35226<br />

Dubai U.A.E.<br />

Tel.: +971 4 2294944<br />

Fax: +971 84 680139<br />

E-mail: wedeco.de@itt.com<br />

08 / 2007 · This brochure has been printed on chlorine-free paper


Description Series <strong>Spektron</strong><br />

Main Applications<br />

Disinfection of clear fresh water to meet relevant biological standards:<br />

• Private and municipal drinking water supplies<br />

• Beverage and food industry<br />

• Process water for industrial use<br />

• Fish farming (fresh water)<br />

The units have a DVGW-Certificate according to DVGW W294-2 (No. DW-9181BS0139)<br />

and an ÖVGW-Certificate according to ÖNORM M5873-1 (No. W 1.430).<br />

Water temperature recommended range 5 – 45°C<br />

possible range 0 – 70°C<br />

Wasser UV transmittance (@ 254 nm, 1 cm) min. 80%<br />

Flow rate (400 J/m² - certified) max. 922 m³/h<br />

Technical Description<br />

• Cylindrical stainless steel reactor with CrossMix flow optimizer (demountable)<br />

• High efficiency low pressure UV lamps, concentrically, easily removable<br />

• Calibrated UV intensity monitoring system<br />

• Electronic UV lamp supervision system with error memory and external interfaces<br />

• Monitoring of reactor temperature and external flow rate signal<br />

• CE and EMV approved<br />

UV Reactor<br />

UV lamp<br />

UV sensor<br />

Material Stainless steel 316L (1.4404)<br />

Mounting horizontal or vertical<br />

Connection type external thread or flanges DIN 2999 / EN 1092-1 Typ 02<br />

Seals O-rings, Fluorocarbon-india rubber (FKM),<br />

DVGW, KTW and FDA approved<br />

Components flow optimizing internals, UV- and temperature sensors,<br />

cleaning valves and fittings for sampling (except <strong>Spektron</strong> 3 + 6)<br />

cylindrical low pressure high efficiency UV lamp<br />

WLR20, WLR30 with WEDECO-Spektrotherm technology (Indium amalgam)<br />

calibrated according to ÖVGW M5873-1 und DVGW W294-3, 160° measuring angle<br />

accuracy ± 3 %, selectivity > 99 % bei 254 nm, ageing stability,<br />

temperature stability up to 70°C during continuous operation<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 1/6


Description Series <strong>Spektron</strong><br />

Electrical<br />

cabinet<br />

Design<br />

Components<br />

Terminals<br />

Painted sheet steel enclosure, wall mounted<br />

Ready for connection, incl. reactor cables of 10 m<br />

Supply voltage <strong>Spektron</strong> 3 – <strong>Spektron</strong> 100:<br />

230 V, 50 - 60 Hz, (TN-S net, TN-C net),<br />

<strong>Spektron</strong> 150 – <strong>Spektron</strong> 600:<br />

400 V, 50–60 Hz, (TN-S net, TN-C net),<br />

power factor ~ 1<br />

Ambient temperature 5 to 35 °C<br />

Main switch, cooling fan<br />

PECO controller with blue-illuminated operator panel<br />

LED indicators: "normal operation", "prealarm", "alarm"<br />

Electronic ballasts with integrated SOFTSTART ignition<br />

UV intensity measuring system with two limit switches<br />

Electronic single lamp surveillance, dokumented error memory<br />

Monitoring of reactor temperature and external flow rate signal<br />

All I/O terminals in one board (TERA/TERB)<br />

LC-display: UV intensity in W/m²<br />

2 operating hours counters (lamp life / total)<br />

On/off cycles<br />

Status messages (available languages: English, French,<br />

German, others in preparation),<br />

Operation, user and service layers (password protected)<br />

In: On / off<br />

UV sensor<br />

Reactor temperature<br />

water flow rate (0/4 – 20 mA)<br />

Out: UV intensity adjustable (0/4 – 20 mA),<br />

Volt-free contacts for:<br />

Normal operation, cleaning, system failure,<br />

High temperature reactor / cabinet,<br />

Interlock flow,<br />

Rinsing interval,<br />

Valve control as reactor temperature protection<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 2/6


Technical <strong>Data</strong> Series <strong>Spektron</strong><br />

Model <strong>Spektron</strong> 3 <strong>Spektron</strong> 6 <strong>Spektron</strong> 15 <strong>Spektron</strong> 25<br />

UV reactor<br />

Connections (thread or flange) 1½" 2" DN 65 DN 80<br />

Cleaning valves ¼" ¼" ¼" ¼"<br />

Dimensions please refer to the respective drawing<br />

Volume (l) approx. 4 13 19 24<br />

Total weight, dry (kg) approx. 5 10 20 25<br />

Operating pressure (bar), max. 16 10<br />

Surface inner pickled / outer electropolished<br />

Protection class IP 65<br />

UV lamp<br />

Type WLR5 WLR10 WLR20 WLR30<br />

Lamp power (W)* 40 70 210 330<br />

UV-C output 254 nm (W) 14 25 73 120<br />

Quantity 1<br />

Lamp life (h) 10,000 12,000<br />

Calibrated UV monitoring system<br />

UV sensor SO 13599 acc. ÖNORM<br />

Electronics PECO<br />

Quantity 1<br />

Standard output signal 0/4 – 20 mA<br />

Electrical cabinet<br />

Width (mm) approx. 350<br />

Height (mm) approx. 370<br />

Depth (mm) approx. 240<br />

Weight (kg) approx. 7<br />

Colour painting RAL 7035, grey; door blue<br />

Power supply (V / Hz) 230 / 50 - 60<br />

Power consumption (kW) approx. 0.055 0.09 0.25 0.38<br />

Protection class IP 54<br />

Mains terminals L / N / PE<br />

Options / accessories (extra charges)<br />

• Cleaning valve <strong>Spektron</strong> 3 & 6<br />

• Reactor cables standard 10 m ( 5 m optional)<br />

• Sample valve (¼“) acc. DIN 38402<br />

Options not included in the sales pricelist have to be requested at Wedeco’s service department<br />

* at 18 °C water temperature<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 3/6


Technical <strong>Data</strong> Series <strong>Spektron</strong><br />

Model <strong>Spektron</strong> 25 S <strong>Spektron</strong> 70 <strong>Spektron</strong> 100<br />

UV reactor<br />

Connections (flange) DN 80 DN 125 DN 150<br />

Cleaning valves ½" ½" ½"<br />

Dimensions please refer to the respective drawing<br />

Volume (l) approx. 88 113 135<br />

Total weight, dry (kg) approx. 74 83 91<br />

Operating pressure (bar), max. 10<br />

Surface inner and outer electropolished<br />

Protection class IP 65<br />

UV lamp<br />

Type WLR10 WLR20 WLR30<br />

Lamp power (W)* 70 210 330<br />

UV-C output 254 nm (W) 25 73 120<br />

Quantity 3<br />

Lamp life (h) 10,000 12,000<br />

Calibrated UV monitoring system<br />

UV sensor SO 13599 acc. ÖNORM M5873-1<br />

Electronics PECO<br />

Quantity 1<br />

Standard output signal 0/4 – 20 mA<br />

Electrical cabinet<br />

Width (mm) approx. 611<br />

Height (mm) approx. 370<br />

Depth (mm) approx. 240<br />

Weight (kg) approx. 22<br />

Colour painting RAL 7035, grey; door blue<br />

Power supply (V / Hz) 230 / 50 - 60<br />

Power consumption (kW) approx. 0.3 0.8 1.0<br />

Protection class IP 54<br />

Mains terminals L / N / PE<br />

Options / accessories (extra charges)<br />

• Reactor cables standard 10 m ( 5 m optional)<br />

• Sample valve (¼“) acc. DIN 38402<br />

Options not included in the sales pricelist have to be requested at Wedeco’s service department<br />

* at 18 °C water temperature<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 4/6


Technical <strong>Data</strong> Series <strong>Spektron</strong><br />

Model <strong>Spektron</strong> 150 <strong>Spektron</strong> 250<br />

UV reactor<br />

Connections (flange) DN 200 DN 250<br />

Cleaning valves ¾" 1"<br />

Dimensions please refer to the respective drawing<br />

Volume (l) approx. 219 434<br />

Total weight, dry (kg) approx. 141 235<br />

Operating pressure (bar), max. 10<br />

Surface inner and outer electropolished<br />

Protection class IP 65<br />

UV lamp<br />

Type WLR30<br />

Lamp power (W)* 330<br />

UV-C output 254 nm (W) 120<br />

Quantity 4 6<br />

Lamp life (h) 12,000<br />

Calibrated UV monitoring system<br />

UV sensor SO 13599 acc. ÖNORM M5873-1<br />

Electronics PECO<br />

Quantity 1<br />

Standard output signal 0/4 – 20 mA<br />

Electrical cabinet<br />

Width (mm) approx. 600<br />

Height (mm) approx. 600<br />

Depth (mm) approx. 350<br />

Weight (kg) approx. 45 50<br />

Colour painting RAL 7035, grey<br />

Power supply (V / Hz) 400 / 50 - 60<br />

Power consumption (kW) approx. 1.5 2.2<br />

Protection class IP 54<br />

Mains terminals 3L / N / PE<br />

Options / accessories (extra charges)<br />

• Reactor cables standard 10 m ( 5 m optional)<br />

• Sample valve (¼“) acc. DIN 38402<br />

Options not included in the sales pricelist have to be requested at Wedeco’s service department<br />

* at 18 °C water temperature<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 5/6


Technical <strong>Data</strong> Series <strong>Spektron</strong><br />

Model <strong>Spektron</strong> 400 <strong>Spektron</strong> 600<br />

UV reactor<br />

Connections (flange) DN 300 DN 350<br />

Cleaning valves 1¼" 1½"<br />

Dimensions please refer to the respective drawing<br />

Volume (l) approx. 540 850<br />

Total weight, dry (kg) approx. 450 650<br />

Operating pressure (bar), max. 10<br />

Surface inner pickled / outer pickled and glass bead blasted<br />

Protection class IP 65<br />

UV lamp<br />

Type WLR 30<br />

Lamp power (W)* 330<br />

UV-C output 254 nm (W) 120<br />

Quantity 8 12<br />

Lamp life (h) 12,000<br />

Calibrated UV monitoring system<br />

UV sensor SO 13599 acc. ÖNORM M5873-1<br />

Electronics PECO<br />

Quantity 1 2<br />

Standard output signal 0/4 – 20 mA<br />

Electrical cabinet<br />

Width (mm) approx. 600<br />

Height (mm) approx. 600<br />

Depth (mm) approx. 350<br />

Weight (kg) approx. 54 56<br />

Colour painting RAL 7035, grey<br />

Power supply (V / Hz) 400 / 50 - 60<br />

Power consumption (kW) approx. 2.95 4.35<br />

Protection class IP 54<br />

Mains terminals 3L / N / PE<br />

Options / accessories (extra charges)<br />

• Reactor cables standard 10 m ( 5 m optional)<br />

• Sample valve (¼“) acc. DIN 38402<br />

Options not included in the sales pricelist have to be requested at Wedeco’s service department<br />

* at 18 °C water temperature<br />

<strong>Spektron</strong> <strong>Data</strong>.doc -Vol. VI-<br />

Subject to change without notice 6/6


A<br />

B<br />

C<br />

D<br />

E<br />

240<br />

1<br />

2<br />

611<br />

575<br />

535<br />

A<br />

310<br />

Kommission:<br />

<strong>Spektron</strong> 25S-100<br />

Datum Name<br />

Bearb. 07-10-2005 Krueger_F<br />

F Gepr. 14.06.2007 Fkrueger<br />

1 2 3 4<br />

3<br />

4<br />

370<br />

15<br />

A (1 : 1)<br />

220<br />

5<br />

6,5<br />

1 Schaltkasten<br />

Nr. Änderung<br />

R6<br />

8,5<br />

18<br />

14.06.2007 Fkrueger<br />

Datum Name<br />

6<br />

Maße ohne<br />

Toleranzangaben<br />

nach ISO 2768m<br />

Norm<br />

EDV Nr.<br />

30<br />

Maßstab 1:5 Gewicht: 0<br />

Werkstoff:<br />

Benennung:<br />

SCHALTSCHRANKANSICHT<br />

ELEKTRICAL CABINET LAYOUT<br />

Zeichnung-Nr.:<br />

U-33452-1<br />

Schaltschrankansicht, <strong>Spektron</strong> 25S-100-+-U-33452.slddrw<br />

7<br />

Nr.:<br />

Schutzvermerk<br />

DIN ISO 16016<br />

beachten<br />

Art.Nr.:<br />

8<br />

Blatt<br />

-<br />

A3<br />

Bl<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!