Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>AP4801</strong> / <strong>AP4001</strong><br />
BATTERY (AP48xx only)<br />
Battery must be enabled by removing plastic isolator that is put between its contacts. (Battery is used<br />
for real time clock on AP48xx)<br />
TAMPER SWITCH<br />
Tamper switch can be read by the software and thus generating an alarm if enclosure is opened.<br />
AEPACK LOCAL TEST (ALT MODE)<br />
ALT mode allows a simple test of the basic functions of AEpack. Switching on/off ALT mode is<br />
logged on server!<br />
Start ALT mode: Press ALT button more than 3 seconds. Status LED blinks fast.<br />
Back to normal operation: No action in ALT mode during 15 minutes or ALT switch pressing again<br />
for 3 seconds. After returning to operation mode the situation from before starting the ALT mode is<br />
restored.<br />
ALT mode for AP4x07: Short activating button will cause a new test situation, tests will loop around:<br />
1 Reads card: ID led blinks, UL led acts like ID led, activates relay 1<br />
2 Relay 1 ON NA and UL led ON, UL led flashes during reading card<br />
3 Relay 1 OFF<br />
Steps 1,2,3 are repeated for all four outputs.<br />
FIRMWARE<br />
Pay attention that the firmware loaded in AEpack and AEpu determines functionality and protocols.<br />
SPECIFICATIONS <strong>AP4801</strong> (Product nr. 9842640) <strong>AP4001</strong> (Product nr. 9842500)<br />
Dimensions: 230 x 345 x 70 mm Weight: ± 900 gr<br />
Power input: 10 – 35VDC 10 – 25VAC <strong>AP4801</strong>: Min. AEpack power consumption: 300mA@24VDC / 600mA@12VDC<br />
<strong>AP4001</strong>: Min. AEpack power consumption: 200mA@24VDC / 300mA@12VDC<br />
Environment: Temperature: Operating: 0 – 55 °C, Storage: -30 – 65 °C Relative humidity: 10 – 93% non condensing<br />
Lock supply: External Additional supply: +5VDC ±10% max 100mA<br />
Inputs: 8: Intended for dry contact or open collector, optional supervised (software selectable)<br />
Outputs: 4: Dry contact (normally open, common, normally closed).<br />
Contact ratings: (Suitable for switching inductive loads, clean relay contacts)<br />
Switching voltage: 24VAC, 48VDC<br />
Continuous current and switching current: 6A (AC and DC)<br />
Contact lifetime: min 500.000 times at given ratings<br />
Indications: 4* UL and NA led for antenna: max 20 mA<br />
Communication: AP48xx: Ethernet: UTP 100/10 Mbps (auto detection)<br />
Service port RS232 (Rx, Tx, GND, RTS, CTS)<br />
Battery: CR2032 (lifetime 2 years if no power present)<br />
Antennas: Only antenna’s with adjustment included can be used, otherwise add adjustment box<br />
UL and NA led for antenna: max 20 mA, (5VDC; R=220E)<br />
Detection distance: RefleXS260 and UniXS card: max 30 cm, RefleXS260 and XM card: 40 cm<br />
CABLE SPECIFICATIONS<br />
Inputs: 2 x 0,25mm², max cable length: 100 meter, cable capacity