2000 Preliminary <strong>In</strong>vestigation Of A Fusselman Location<br />

(Conducted by GeothermEx, GeothermEx,<br />

<strong>In</strong>c. for Client Company)<br />

Formation Characteristics<br />

- Depth: ±19,000 19,000 ft<br />

- Net Pay: 200-600 200 600 ft (w. water zone)<br />

- Porosity: 6-10 6 10 %<br />

- Permeability: ~25 md<br />

- Transmissivity kh: kh:<br />

~10,000 md ft<br />

Well Characteristics<br />

- Well Size: variable<br />

13-3/8 13 3/8” casing to 5,000-14,000 5,000 14,000 ft<br />

10-3/4 10 3/4” casing below to formation top<br />

6-1/2 1/2” open hole below<br />

2-7/8 7/8” or 3-1/2 3 1/2” tubing for production<br />

- Well Spacing: 3,700 ft apart<br />

Fluid Characteristics<br />

- Reservoir Pressure: 9,000 psia<br />

- Reservoir T: 280 oF F (137.8 oC) C)<br />

- <strong>Geothermal</strong> Gradient: 1.1 oF/100 F/100 ft<br />

(nonlinear = ~ 2.8 oF/100 F/100 ft)<br />

- Gas Gravity: 0.58<br />

- H2S S Content in Gas: 0.1%<br />

- Heating Vol. of Gas: 870 Btu/MCF<br />

- Brine Salinity: 130,000 ppm<br />

- Gas Content in Brine: 40 mcf/bbl<br />

Courtesy Subir Sanyal