BVM-L / PVM-L Series - Sony Professional Solutions Asia Pacific
BVM-L / PVM-L Series - Sony Professional Solutions Asia Pacific
BVM-L / PVM-L Series - Sony Professional Solutions Asia Pacific
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BKM-250TG<br />
INPUT/OUTPUT<br />
BNC (x2),<br />
Digital component signals Sampling frequency<br />
3G-SDI: Y/Cb/Cr: 148.5 MHz/74.25 MHz/74.25 MHz,<br />
Serial Digital Interface<br />
G/B/R: 148.5 MHz/148.5 MHz/148.5 MHz<br />
HD-SDI: Y/Cb/Cr: 74.25 MHz/37.125 MHz/37.125 MHz,<br />
SD-SDI: Y/Cb/Cr: 13.5 MHz/6.75 MHz/6.75 MHz<br />
BNC (x2),<br />
Monitor Out<br />
Output signal amplitude: 800 mVp-p ± 10 %<br />
Output impedance: 75 Ω unbalanced<br />
3G-SDI: 70 m (approx. 230 ft) max.<br />
(When using 5C-FB coaxial cables (Fujikura. Inc.) or equivalent.)<br />
HD-SDI: 100 m (approx. 328 ft) max.<br />
Transmission Distance<br />
(When using 5C-FB coaxial cables (Fujikura. Inc.) or equivalent.)<br />
SD-SDI:200 m (approx. 656 ft) max.<br />
(When using 5C-2V coaxial cables (Fujikura. Inc.) or equivalent.)<br />
GENERAL<br />
Voltage +3.3 V, +5 V (supplied from the main unit)<br />
Power Consumption Approx. 4 W<br />
0 °C to 35 °C (32 °F to 95 °F)<br />
Operating Temperature<br />
(Optimum temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure 700 hPa to 1060 hPa<br />
Storage and Trans. Temperature -20 °C to +60 °C (-4 °F to 140 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 270 g (9.5 oz)<br />
Supplied Accessories Operating Instructions (1)<br />
BKM-243HS<br />
INPUT/OUTPUT<br />
BNC (x2),<br />
Digital Component Signals<br />
Serial Digital Interface<br />
Sampling Frequency: SD-SDI: Y/R-Y/B-Y: 13.5 MHz,<br />
HD-SDI: Y/Pb/Pr: 74.25 MHz<br />
Quantization: 10 bits/sample<br />
BNC (x1),<br />
Monitor Out<br />
Output signal amplitude: 800 mVp-p ± 10 %<br />
Output impedance: 75 Ω unbalanced<br />
SD-SDI: 200 m (approx. 656 ft) max. (when using<br />
5C-2V coaxial calbes (Fujikura) or equivalent)<br />
Transmission Distance<br />
HD-SDI: 100 m (approx. 328 ft) max. (when using<br />
5C-FB coaxial cables (Fujikura) or equivalent)<br />
GENERAL<br />
Voltage +3.3 V, +5 V (supplied from the main unit)<br />
Power Consumption Approx. 2 W<br />
0 °C to 35 °C (32 °F to 95 °F) (Recommended<br />
Operating Temperature<br />
operation temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure 700 hPa to 1060 hPa<br />
Storage and Trans. Temperature -20 °C to 40 °C (-4 °F to 140 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 250 g (9 oz)<br />
BKM-227W<br />
INPUT/OUTPUT<br />
Composite Input<br />
BNC (x1),<br />
1 Vp-p ± 3 dB sync negative<br />
Mini DIN 4-pin (x1)<br />
Y/C Input<br />
Y: 1 Vp-p ± 3 dB sync negative<br />
C: 0.286 Vp-p ± 3 dB (NTSC burst signal level),<br />
0.3 Vp-p ± 3 dB (PAL, PAL-M burst signal level)<br />
BNC (x1),<br />
Monitor Out<br />
GENERAL<br />
Loop-through, with 75 Ω automatic termination<br />
Mini DIN 4-pin (x1),<br />
Loop-through, with 75 Ω automatic termination<br />
Voltage +3.3 V, +5 V (supplied from the main unit)<br />
Power Consumption Approx. 1.8 W<br />
Operating Temperature<br />
0 °C to 35 °C (32 °F to 95 °F) (Recommended<br />
operation temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure 700 hPa to 1060 hPa<br />
Storage and Trans. Temperature -20 °C to 60 °C (-4 °F to 140 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 240 g (8 oz)<br />
Supplied Accessories Operating Instructions (1)<br />
BKM-244CC<br />
INPUT/OUTPUT<br />
BNC (x2),<br />
Digital Component Signals<br />
Serial Digital Interface<br />
Sampling Frequency: SD-SDI: Y/R-Y/B-Y: 13.5 MHz,<br />
HD-SDI: Y/Pb/Pr: 74.25 MHz<br />
Quantization: 10 bits/sample<br />
BNC (x1),<br />
Monitor Out<br />
Output signal amplitude: 800 mVp-p ± 10 %<br />
Output impedance: 75 Ω unbalanced<br />
SD-SDI: 200 m (approx. 656 ft) max. (when using<br />
5C-2V coaxial calbes (Fujikura) or equivalent)<br />
Transmission Distance<br />
HD-SDI: 100 m (approx. 328 ft) max. (when using<br />
5C-FB coaxial cables (Fujikura) or equivalent)<br />
GENERAL<br />
Voltage +3.3 V, +5 V (supplied from the main unit)<br />
Power Consumption Approx. 4 W<br />
0 °C to 35 °C (32 °F to 95 °F) (Recommended<br />
Operating Temperature<br />
operation temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure 700 hPa to 1060 hPa<br />
Storage and Trans. Temperature -10 °C to 40 °C (14 °F to 104 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 250 g (9 oz)<br />
Supplied Accessories Operating Instructions (1)<br />
BKM-229X<br />
Supplied Accessories Operating Instructions (1) INPUT/OUTPUT<br />
20<br />
INPUT/OUTPUT<br />
BNC (x3)<br />
RGB Input<br />
0.7 Vp-p ± 3 dB (Sync on Green, 0.3 Vp-p sync negative)<br />
Component Input<br />
0.7 Vp-p ± 3 dB<br />
BNC (x1),<br />
External Sync Input<br />
GENERAL<br />
0.3 to 4 Vp-p ± bipolarity ternary or negative polarity binary<br />
Mini DIN 4-pin (x1),<br />
Loop-through, with 75 Ω automatic termination<br />
Voltage +3.3 V, +5 V (supplied from the main unit)<br />
Power Consumption Approx. 4 W<br />
Operating Temperature<br />
0 °C to 35 °C (32 °F to 95 °F) (Recommended<br />
operation temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure 700 hPa to 1060 hPa<br />
Storage and Trans.<br />
Temperature<br />
-20 °C to 60 °C (-4 °F to 140 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 250 g (9 oz)<br />
Supplied Accessories Operating Instructions (1)<br />
BKM-220D<br />
Serial Digital Interface<br />
Monitor Out<br />
Transmission Distance<br />
GENERAL<br />
Voltage<br />
Power Consumption<br />
Operating Temperature<br />
BNC (x2),<br />
Digital Component Signals<br />
Sampling Frequency: Y/R-Y/B-Y: 13.5 MHz<br />
Quantization: 10 bits/sample<br />
BNC (x1),<br />
Output signal amplitude: 800 mVp-p ±10 %<br />
Output impedance: 75 Ω unbalanced<br />
200 m (approx. 656 ft) max. (when using<br />
5C-2V coaxial calbes (Fujikura) or equivalent)<br />
+5 V (supplied from the main unit)<br />
Approx. 1.5 W<br />
0 °C to 35 °C (32 °F to 95 °F) (Recommended<br />
operation temperature 20 °C to 30 °C (68 °F to 86 °F))<br />
Operating Humidity 0 % to 90 % (no condensation)<br />
Operating Pressure<br />
700 hPa to 1060 hPa<br />
Storage and Trans.<br />
Temperature<br />
-20 °C to 60 °C (-4 °F to 140 °F)<br />
Storage and Trans. Humidity 0 % to 90 %<br />
Storage and Trans. Pressure 700 hPa to 1060 hPa<br />
Dimensions (W x H x D) 100 x 20 x 162 mm (4 x 13 /16 x 6 1 /2 inches)<br />
Mass Approx. 250 g (9 oz)<br />
Supplied Accessories Operating Instructions (1)