2. Operation<br />
Warming up<br />
Turn on the mains supply through the green switch on the front panel. The lamp will<br />
ignite and the fan will begin to operate. After a warm-up time of approximately 15<br />
minutes the lamp reaches its full power. Switching off during warm-up can damage<br />
the lamp. Every ignition wears the lamp, similar to the cold start of a car engine, we<br />
therefore recommend not to switch off the unit if you need it again within the next<br />
three hours.<br />
Shutter and Timer<br />
After pressing the orange starter button the shutter will open for the selected amount<br />
of time (selectable from 0.1 to 999.9 seconds) and release the UV radiation; holding<br />
the starter button will extend exposure time. If the timer is set to “000.0”, the shutter<br />
will open only as long as the orange starter button is pressed; alternatively the timer<br />
can be switched off on the rear panel. The footswitch which can be connected to the<br />
rear panel has the same function as the orange starter button. For integration into<br />
external control systems the footswitch can be replaced by a galvanically isolated<br />
closing contact.<br />
Switching off<br />
The green switch on the front panel will turn off the lamp and the mains supply.<br />
Reignition<br />
If the unit is switched off, allow the lamp to cool down for at least 10 minutes prior to<br />
reignition. Do not attempt reignition earlier as this may damage the lamp.<br />
3. Special Instructions<br />
Lamp Life<br />
Based on operating intervals of a normal working day UV radiation power of the<br />
lamp will drop to approximately 50% after 600 operating hours, and the lampmodule<br />
should then be replaced.<br />
Repairs and Service<br />
Always disconnect power cord before opening up the unit. Do not attempt any<br />
repairs other than exchanging the lamp-module (see instructions “Changing the<br />
Lamp-Module”). Refer all other repairs to an authorized service facility.<br />
5