2. Operation<br />

Warming up<br />

Turn on the mains supply through the green switch on the front panel. The lamp will<br />

ignite and the fan will begin to operate. After a warm-up time of approximately 15<br />

minutes the lamp reaches its full power. Switching off during warm-up can damage<br />

the lamp. Every ignition wears the lamp, similar to the cold start of a car engine, we<br />

therefore recommend not to switch off the unit if you need it again within the next<br />

three hours.<br />

Shutter and Timer<br />

After pressing the orange starter button the shutter will open for the selected amount<br />

of time (selectable from 0.1 to 999.9 seconds) and release the UV radiation; holding<br />

the starter button will extend exposure time. If the timer is set to “000.0”, the shutter<br />

will open only as long as the orange starter button is pressed; alternatively the timer<br />

can be switched off on the rear panel. The footswitch which can be connected to the<br />

rear panel has the same function as the orange starter button. For integration into<br />

external control systems the footswitch can be replaced by a galvanically isolated<br />

closing contact.<br />

Switching off<br />

The green switch on the front panel will turn off the lamp and the mains supply.<br />

Reignition<br />

If the unit is switched off, allow the lamp to cool down for at least 10 minutes prior to<br />

reignition. Do not attempt reignition earlier as this may damage the lamp.<br />

3. Special Instructions<br />

Lamp Life<br />

Based on operating intervals of a normal working day UV radiation power of the<br />

lamp will drop to approximately 50% after 600 operating hours, and the lampmodule<br />

should then be replaced.<br />

Repairs and Service<br />

Always disconnect power cord before opening up the unit. Do not attempt any<br />

repairs other than exchanging the lamp-module (see instructions “Changing the<br />

Lamp-Module”). Refer all other repairs to an authorized service facility.<br />