<strong>AIM</strong>: - <strong>To</strong> <strong>perform</strong> penetration <strong>test</strong> on the given sample of bitumen<br />
APPARATUS :-<br />
FIGURE :-<br />
THEORY :-<br />
PROCEDURE :-<br />
OBSERVATION TABLE :-<br />
Penetrometer is penetration <strong>test</strong> apparatus<br />
The penetration <strong>test</strong> determines the hardness and so ftness<br />
of bitumen by measuring the depth of needle in mm to which a standard<br />
loaded needle penetrates vertically 5 sec . The sample is maintained at 250<br />
C.<br />
A bitumen sample of depth about 15mm. is taken into a<br />
container . The sample is arranged on the instrument that the standard<br />
needle just touches the surface of the bitumen sample . The dial is set to<br />
zero . Now initial reading is taken and the needle is released for 5 sec. and<br />
the final reading is taken on the dial gauge . Three reading should be tak en.<br />
Each <strong>test</strong> should be <strong>perform</strong>ed for at least 10 min apart from each other and<br />
the mean value is taken .<br />
Sr Initial Reading Final Reading Differ ence Penetration<br />
No. 1/10 mm 1/10 mm 1/10 mm Value<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Average<br />
Penetration<br />
Value