SLT <strong>PCL5</strong><br />
<strong>TRABECULAS</strong><br />
S L T - L A S E R<br />
The STAR of SLT Systems<br />
High-Class optics included - ideal for anterior<br />
and posterior segment viewing<br />
Promotes cellular regeneration of trabecular<br />
meshwork<br />
Repeatable laser treatment<br />
A laser therapy which<br />
may replace medication<br />
for the treatment of openangle<br />
glaucoma (OAG)
PCL 5 SHL<br />
SLIT LAMP & LASER<br />
The cutting edge of Selective <strong>Laser</strong> Trabeculoplasty<br />
SLT-Systems! Precision optics combined with a fully coaxial<br />
laser coupled to the slit lamp, sets the standard in today’s<br />
market. Unique features such as the Neutral Colour Design<br />
filter and the brillant optics of our <strong>PCL5</strong> allow the ultimate<br />
performance for selective laser trabeculoplasty (SLT). With the<br />
The Optic design assures coaxial<br />
viewing with laser delivery.<br />
The laser spot is there where you need it.<br />
<strong>TRABECULAS</strong> laser controller.<br />
laser console on the table, all functions are easily accessible by<br />
your finger tips from the base of the slit lamp.<br />
<strong>TRABECULAS</strong> SLT <strong>Laser</strong>: advanced laser system aimed at<br />
reducing intraocular pressure for long term satisfaction while<br />
preserving the trabeculum.<br />
It’s what is known as PERFECTION.<br />
Always at your fingertips: aiming beam and laser beam –<br />
precise and pinpoint.
Attached to a modern <strong>PCL5</strong> slit lamp, our user friendly<br />
Trabeculas laser features a high level of precision. This gives<br />
you a premium SLT-instrument you can rely on for many years.<br />
A.R.C. <strong>Laser</strong> STANDARD:<br />
• Permanent safety filter to protect the doctor from<br />
reflecting laser light.<br />
• You can remov the laser mirror to use the slit lamp optic<br />
and illumination without any restriction.<br />
The SLT does not interfere with a tonometer or a video system.<br />
Automatic or permanent - Neutral<br />
Color filter design to protect you<br />
from reflecting laser light<br />
Choose from a wide range of<br />
contact lenses.
<strong>TRABECULAS</strong><br />
S L T - L A S E R<br />
teCHniSCHe Daten<br />
<strong>PCL5</strong> ZD<br />
Spaltbreite (bei 180°) 0 bis 16 mm kontinuierlich<br />
Spalthöhe 1 bis 16 mm kontinuierlich<br />
Leuchtfelder Kreis ø: 1 mm Testmarke<br />
Spaltdrehung ± 90° (0-180°)<br />
Verstellbarkeit der<br />
Beleuchtung<br />
horizontal ± 90°<br />
Filter blau, rotfrei (grün), grau (10%).<br />
UV und Wärmefilter sind integriert<br />
Beleuchtung Halogen 6 V, 20 W<br />
0 lux bis 600,000 lux (Halogen)<br />
optional: LED 14 V, 5 W<br />
Arztschutzfilter optional<br />
Elektr. Anschlusswerte 110 V - 240 V 50/60 Hz<br />
Gewicht 12,7 kg<br />
<strong>PCL5</strong> SHD<br />
Spaltbreite (bei 180°) 0 bis 8 mm kontinuierlich<br />
Spalthöhe 0,5 - 8 mm kontinuierlich<br />
Leuchtfelder Kreis 0,2; 1; 2; 3; 4; 6; 8 mm Testmarke mit Fixation<br />
Spaltdrehung ± 90° (0-180°)<br />
Verstellbarkeit der<br />
horizontal ± 90°<br />
Beleuchtung<br />
vertikal 0-20°<br />
Filter blau, rotfrei (grün), grau (10%).<br />
UV und Wärmefilter sind integriert<br />
Beleuchtung Halogen 6 V, 20 W<br />
0 lux bis 600,000 lux (Halogen)<br />
optional: LED 14 V, 5 W<br />
Arztschutzfilter optional<br />
Elektr. Anschlusswerte 110 V - 240 V, 50/60 Hz<br />
Gewicht 12,7 kg<br />
A simple knob at the illumination tower<br />
easily removes the laser mirror to use the<br />
slit lamp optic and illumination without<br />
Stereomikroskop<br />
Stereowinkel 10°<br />
any restriction.<br />
Okulare einstellbar ± 8 dpt<br />
Vergrößerungen 6.3x / 10x / 16x / 25x / 40x<br />
Okularvergrösserung 12,5x<br />
PD 52 to 78 mm<br />
Schwenkung der<br />
± 30°<br />
Mikroskopachse horizontal<br />
Our commitment is to supply our customers<br />
with the best quality products with the latest<br />
innovations and broadest range of accessories<br />
– available from a single source.<br />
A.R.C. <strong>Laser</strong> in Germany is a privately held<br />
company to better serve you.<br />
A.R.C. <strong>Laser</strong> GmbH<br />
Bessemerstraße 14<br />
A.R.C. D-90411 <strong>Laser</strong> Nürnberg GmbH<br />
Bessemerstraße Germany 14<br />
<strong>PCL5</strong> D-90411 Nürnberg<br />
Germany<br />
® SHD<br />
S P A L T L A M P E<br />
<strong>PCL5</strong><br />
� +49 (0) 911 217 79 -0<br />
� +49 (0) 911 217 79 99<br />
� info@arclaser.de<br />
+49 (0) 911 217 79 -0<br />
� www.arclaser.de<br />
+49 (0) 911 217 79 99<br />
info@arclaser.de<br />
www.arclaser.de<br />
SPeCifiCationS SLit LamPS<br />
<strong>PCL5</strong> ZD<br />
Slit width 0 to16 mm continuous<br />
Slit length 1 to 16 mm continuous<br />
Slit diaphragm ø 1 mm<br />
A LASER THERAPY WHICH MAY REPLACE<br />
Slit rotation ± 90° (0-180°)<br />
Illumination unit swing horizontal ± 90°<br />
MEDICATION FOR THE TREATMENT OF<br />
Filters blue, redfree (green), grey (10%)<br />
UV and heat absorption are pre installed<br />
OPEN-ANGLE Illumination GLAUCOMA Halogen 6 V, 20 W (OAG)<br />
0 lux to 600,000 lux (Halogen)<br />
optional: LED 14 V, 5 W<br />
Eye protection filter optional<br />
Power requ. 110 V - 240 V 50/60 Hz<br />
Weight 12.7 kg<br />
SPECIFICATIONS SLIT LAMP<br />
<strong>PCL5</strong> SHL<br />
<strong>PCL5</strong> SHD<br />
Slit width 0 to 8 mm continuous<br />
Slit length 0.5 to 8 mm continuous<br />
Illumination field diameter 0.2, 1, 2, 3, 4, 6, 8 mm<br />
Slit rotation ± 90° (0-180°)<br />
Illumination unit swing horizontal ± 90°<br />
vertical 0-20°<br />
Filters blue, redfree (green), grey (10%)<br />
UV and IR filters are built-in<br />
Illumination Halogen 6 V, 20 W<br />
0 lux to 600,000 lux (Halogen)<br />
optional: LED 14 V, 5 W<br />
Eye protection filter optional<br />
Power requ. 110 V - 240 V 50/60 Hz<br />
Weight 12.7 kg<br />
Stereo microscope<br />
Stereo angle full 10°<br />
Oculars ± 8 D<br />
Magnification 6.3x / 10x / 16x / 25x / 40x<br />
Ocular magnification 12,5x<br />
Pupillar distance 52 to 78 mm<br />
Microscope unit swing<br />
horizontal<br />
± 30°<br />
SPECIFICATIONS LASER<br />
<strong>TRABECULAS</strong> SLT<br />
<strong>Laser</strong> Q-switched 532 nm<br />
frequency doubled Nd:YAG<br />
Output energy 0.2 / 0.4 / 0.6 / 0.8 / 0.9 / 1.0 / 1.1 / 1.2 / 1.5 2.0 mJ<br />
in 10 steps<br />
Spot size in mm 400 µm at aiming beam focus<br />
CLASSIC GREEN LASER<br />
Puls Rep. Rate 1 Hz on demand<br />
Puls width 3 ns<br />
Aiming Beam Red diode, adjustable intensity<br />
<strong>Laser</strong> Cone Angle 3,2°<br />
<strong>Laser</strong> Delivery Through slit lamp illumination<br />
Design Fixed arm at slit projector<br />
Weight 53 kg with slit lamp<br />
Footprint 0.5 m 2<br />
Power requirement 230 V, 50 Hz, 3 A bei 230 V<br />
Technical data is<br />
subject to change<br />
without notice.<br />
VISIBLE AND INVISIBLE LASER RADIATION<br />
AVOID EYE OR SKIN EXPOSURE TO<br />
DIRECT OR SCATTERED RADIATION<br />
Nd:YAG LASER 532 < 2 mJ<br />
DIODE LASER 635 nm < 5 mW CW<br />
CLASS 3 B LASER PRODUCT<br />
Your local distributor:<br />
Your local distributor:<br />
<strong>PCL5</strong> ® ZD<br />
S P A L T L A M P E<br />
LASER RADIATION<br />
avoid exposure to beam<br />
CLASS 3B LASER PRODUCT<br />
532 nm < 2 mJ<br />
635 nm, P < 5 mW<br />
Specifications are subject to change without notice.<br />
07 / 2012<br />
A.R.C. <strong>Laser</strong> A.R.C. certifies <strong>Laser</strong> that certifies the product that the complies product complies to 21 CFR to 1040.10 21 CFR and 1040.10 1040.11 and EN 1040.11 13485/ EN 2003 13485/ - 93/42 2003 EWG - 93/42 EWG