SLT <strong>PCL5</strong><br />

<strong>TRABECULAS</strong><br />

S L T - L A S E R<br />

The STAR of SLT Systems<br />

High-Class optics included - ideal for anterior<br />

and posterior segment viewing<br />

Promotes cellular regeneration of trabecular<br />

meshwork<br />

Repeatable laser treatment<br />

A laser therapy which<br />

may replace medication<br />

for the treatment of openangle<br />

glaucoma (OAG)


PCL 5 SHL<br />

SLIT LAMP & LASER<br />

The cutting edge of Selective <strong>Laser</strong> Trabeculoplasty<br />

SLT-Systems! Precision optics combined with a fully coaxial<br />

laser coupled to the slit lamp, sets the standard in today’s<br />

market. Unique features such as the Neutral Colour Design<br />

filter and the brillant optics of our <strong>PCL5</strong> allow the ultimate<br />

performance for selective laser trabeculoplasty (SLT). With the<br />

The Optic design assures coaxial<br />

viewing with laser delivery.<br />

The laser spot is there where you need it.<br />

<strong>TRABECULAS</strong> laser controller.<br />

laser console on the table, all functions are easily accessible by<br />

your finger tips from the base of the slit lamp.<br />

<strong>TRABECULAS</strong> SLT <strong>Laser</strong>: advanced laser system aimed at<br />

reducing intraocular pressure for long term satisfaction while<br />

preserving the trabeculum.<br />

It’s what is known as PERFECTION.<br />

Always at your fingertips: aiming beam and laser beam –<br />

precise and pinpoint.


Attached to a modern <strong>PCL5</strong> slit lamp, our user friendly<br />

Trabeculas laser features a high level of precision. This gives<br />

you a premium SLT-instrument you can rely on for many years.<br />

A.R.C. <strong>Laser</strong> STANDARD:<br />

• Permanent safety filter to protect the doctor from<br />

reflecting laser light.<br />

• You can remov the laser mirror to use the slit lamp optic<br />

and illumination without any restriction.<br />

The SLT does not interfere with a tonometer or a video system.<br />

Automatic or permanent - Neutral<br />

Color filter design to protect you<br />

from reflecting laser light<br />

Choose from a wide range of<br />

contact lenses.


<strong>TRABECULAS</strong><br />

S L T - L A S E R<br />

teCHniSCHe Daten<br />

<strong>PCL5</strong> ZD<br />

Spaltbreite (bei 180°) 0 bis 16 mm kontinuierlich<br />

Spalthöhe 1 bis 16 mm kontinuierlich<br />

Leuchtfelder Kreis ø: 1 mm Testmarke<br />

Spaltdrehung ± 90° (0-180°)<br />

Verstellbarkeit der<br />

Beleuchtung<br />

horizontal ± 90°<br />

Filter blau, rotfrei (grün), grau (10%).<br />

UV und Wärmefilter sind integriert<br />

Beleuchtung Halogen 6 V, 20 W<br />

0 lux bis 600,000 lux (Halogen)<br />

optional: LED 14 V, 5 W<br />

Arztschutzfilter optional<br />

Elektr. Anschlusswerte 110 V - 240 V 50/60 Hz<br />

Gewicht 12,7 kg<br />

<strong>PCL5</strong> SHD<br />

Spaltbreite (bei 180°) 0 bis 8 mm kontinuierlich<br />

Spalthöhe 0,5 - 8 mm kontinuierlich<br />

Leuchtfelder Kreis 0,2; 1; 2; 3; 4; 6; 8 mm Testmarke mit Fixation<br />

Spaltdrehung ± 90° (0-180°)<br />

Verstellbarkeit der<br />

horizontal ± 90°<br />

Beleuchtung<br />

vertikal 0-20°<br />

Filter blau, rotfrei (grün), grau (10%).<br />

UV und Wärmefilter sind integriert<br />

Beleuchtung Halogen 6 V, 20 W<br />

0 lux bis 600,000 lux (Halogen)<br />

optional: LED 14 V, 5 W<br />

Arztschutzfilter optional<br />

Elektr. Anschlusswerte 110 V - 240 V, 50/60 Hz<br />

Gewicht 12,7 kg<br />

A simple knob at the illumination tower<br />

easily removes the laser mirror to use the<br />

slit lamp optic and illumination without<br />

Stereomikroskop<br />

Stereowinkel 10°<br />

any restriction.<br />

Okulare einstellbar ± 8 dpt<br />

Vergrößerungen 6.3x / 10x / 16x / 25x / 40x<br />

Okularvergrösserung 12,5x<br />

PD 52 to 78 mm<br />

Schwenkung der<br />

± 30°<br />

Mikroskopachse horizontal<br />

Our commitment is to supply our customers<br />

with the best quality products with the latest<br />

innovations and broadest range of accessories<br />

– available from a single source.<br />

A.R.C. <strong>Laser</strong> in Germany is a privately held<br />

company to better serve you.<br />

A.R.C. <strong>Laser</strong> GmbH<br />

Bessemerstraße 14<br />

A.R.C. D-90411 <strong>Laser</strong> Nürnberg GmbH<br />

Bessemerstraße Germany 14<br />

<strong>PCL5</strong> D-90411 Nürnberg<br />

Germany<br />

® SHD<br />

S P A L T L A M P E<br />

<strong>PCL5</strong><br />

� +49 (0) 911 217 79 -0<br />

� +49 (0) 911 217 79 99<br />

� info@arclaser.de<br />

+49 (0) 911 217 79 -0<br />

� www.arclaser.de<br />

+49 (0) 911 217 79 99<br />

info@arclaser.de<br />

www.arclaser.de<br />

SPeCifiCationS SLit LamPS<br />

<strong>PCL5</strong> ZD<br />

Slit width 0 to16 mm continuous<br />

Slit length 1 to 16 mm continuous<br />

Slit diaphragm ø 1 mm<br />

A LASER THERAPY WHICH MAY REPLACE<br />

Slit rotation ± 90° (0-180°)<br />

Illumination unit swing horizontal ± 90°<br />

MEDICATION FOR THE TREATMENT OF<br />

Filters blue, redfree (green), grey (10%)<br />

UV and heat absorption are pre installed<br />

OPEN-ANGLE Illumination GLAUCOMA Halogen 6 V, 20 W (OAG)<br />

0 lux to 600,000 lux (Halogen)<br />

optional: LED 14 V, 5 W<br />

Eye protection filter optional<br />

Power requ. 110 V - 240 V 50/60 Hz<br />

Weight 12.7 kg<br />

SPECIFICATIONS SLIT LAMP<br />

<strong>PCL5</strong> SHL<br />

<strong>PCL5</strong> SHD<br />

Slit width 0 to 8 mm continuous<br />

Slit length 0.5 to 8 mm continuous<br />

Illumination field diameter 0.2, 1, 2, 3, 4, 6, 8 mm<br />

Slit rotation ± 90° (0-180°)<br />

Illumination unit swing horizontal ± 90°<br />

vertical 0-20°<br />

Filters blue, redfree (green), grey (10%)<br />

UV and IR filters are built-in<br />

Illumination Halogen 6 V, 20 W<br />

0 lux to 600,000 lux (Halogen)<br />

optional: LED 14 V, 5 W<br />

Eye protection filter optional<br />

Power requ. 110 V - 240 V 50/60 Hz<br />

Weight 12.7 kg<br />

Stereo microscope<br />

Stereo angle full 10°<br />

Oculars ± 8 D<br />

Magnification 6.3x / 10x / 16x / 25x / 40x<br />

Ocular magnification 12,5x<br />

Pupillar distance 52 to 78 mm<br />

Microscope unit swing<br />

horizontal<br />

± 30°<br />

SPECIFICATIONS LASER<br />

<strong>TRABECULAS</strong> SLT<br />

<strong>Laser</strong> Q-switched 532 nm<br />

frequency doubled Nd:YAG<br />

Output energy 0.2 / 0.4 / 0.6 / 0.8 / 0.9 / 1.0 / 1.1 / 1.2 / 1.5 2.0 mJ<br />

in 10 steps<br />

Spot size in mm 400 µm at aiming beam focus<br />

CLASSIC GREEN LASER<br />

Puls Rep. Rate 1 Hz on demand<br />

Puls width 3 ns<br />

Aiming Beam Red diode, adjustable intensity<br />

<strong>Laser</strong> Cone Angle 3,2°<br />

<strong>Laser</strong> Delivery Through slit lamp illumination<br />

Design Fixed arm at slit projector<br />

Weight 53 kg with slit lamp<br />

Footprint 0.5 m 2<br />

Power requirement 230 V, 50 Hz, 3 A bei 230 V<br />

Technical data is<br />

subject to change<br />

without notice.<br />

VISIBLE AND INVISIBLE LASER RADIATION<br />

AVOID EYE OR SKIN EXPOSURE TO<br />

DIRECT OR SCATTERED RADIATION<br />

Nd:YAG LASER 532 < 2 mJ<br />

DIODE LASER 635 nm < 5 mW CW<br />

CLASS 3 B LASER PRODUCT<br />

Your local distributor:<br />

Your local distributor:<br />

<strong>PCL5</strong> ® ZD<br />

S P A L T L A M P E<br />

LASER RADIATION<br />

avoid exposure to beam<br />

CLASS 3B LASER PRODUCT<br />

532 nm < 2 mJ<br />

635 nm, P < 5 mW<br />

Specifications are subject to change without notice.<br />