DIVERSION WEIR<br />
To be designed to pass the probable maximum flood<br />
through gates.<br />
With narrow diversion sites the cost of construct<strong>in</strong>g a<br />
weir with gates becomes higher due to excavation<br />
cost for widen<strong>in</strong>g the <strong>river</strong> section to provide enough<br />
section to pass the flood.<br />
For Santoodhar – II<br />
- Cost of ungated overflow weir Rs. 34.33 Million<br />
- Cost of gated weir Rs. 52.45 Million<br />
Hence, overflow type ungated weir<br />
with under sluice adopted.<br />