DIVERSION WEIR<br />

To be designed to pass the probable maximum flood<br />

through gates.<br />

With narrow diversion sites the cost of construct<strong>in</strong>g a<br />

weir with gates becomes higher due to excavation<br />

cost for widen<strong>in</strong>g the <strong>river</strong> section to provide enough<br />

section to pass the flood.<br />

For Santoodhar – II<br />

- Cost of ungated overflow weir Rs. 34.33 Million<br />

- Cost of gated weir Rs. 52.45 Million<br />

Hence, overflow type ungated weir<br />

with under sluice adopted.<br />