24.08.2013 Views

Varilux Physio f-360?? - Essilor

Varilux Physio f-360?? - Essilor

Varilux Physio f-360?? - Essilor

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>˚ <br />

High Resolution Vision with Fitting Conditions


The Best is getting better<br />

<strong>Varilux</strong> <strong>Physio</strong> continues to confirm its position at the top<br />

of the <strong>Varilux</strong> universal range of lenses and today there are<br />

millions of wearers worldwide using the lens.<br />

<strong>Essilor</strong> has once again broken new ground in terms of lens<br />

design with the introduction of a new personalised <strong>Varilux</strong>:<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°. The new lens takes High Resolution<br />

Vision to a new level thanks to personalisation of the design,<br />

with fitting conditions.<br />

The design features of <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° are still based<br />

on those of the original <strong>Varilux</strong> <strong>Physio</strong> lens and include two<br />

major concepts, Wavefront Management and Point by Point<br />

Twinning.<br />

Incident<br />

wavefront<br />

Refracted wavefront<br />

with aberrations<br />

Advanced Digital Surfacing<br />

Wavefront Management System<br />

The Wavefront Management System is a design approach that<br />

considers the wavefront of the beam of light entering the pupil.<br />

Quality of vision depends on how much the wavefront is distorted<br />

by both sides of the lens.<br />

Optimising the wavefront through the front and rear surface of the lens<br />

greatly reduces aberrations including higher order aberrations like the coma.<br />

Point by Point Twinning<br />

Calculation<br />

With both lens surfaces affecting the quality of the wavefront, in order to<br />

maintain optimal optical performance in all directions of gaze, <strong>Essilor</strong>’s<br />

patented innovative new calculation software exactly matches the front and<br />

rear surfaces at all points on the lens.<br />

Manufacture<br />

To ensure the optimal performance of very complex progressive surfaces<br />

across a very large prescription range, <strong>Essilor</strong> has developed an Advanced<br />

Digital Surfacing technology, an extremely accurate manufacturing process<br />

that creates the required surface.<br />

Design Summary<br />

This innovative approach to design and processing means that wearers using<br />

<strong>Varilux</strong> <strong>Physio</strong> can benefit from significant improvements in the three main<br />

visual areas:<br />

Distance vision<br />

The higher order abberation coma is controlled, delivering superior<br />

visual sharpness<br />

Intermediate<br />

The axis of unwanted peripheral surface astigmatism is controlled in<br />

a vertical direction, delivering wider areas of clear vision<br />

Near<br />

The power of the near zone is controlled over a larger vertical area<br />

giving greater visual and postural comfort.


Refining <strong>Varilux</strong> <strong>Physio</strong><br />

Studies have shown that the performance of any varifocal lens can<br />

vary significantly depending on the relative position of the eye and the<br />

spectacles. The position of the spectacles to the face of the wearer has<br />

an impact on the integrity of the wavefront passing through the lens and<br />

entering the eye and therefore on the overall visual performance.<br />

These studies highlight that all areas of the lens are affected; however,<br />

in particular, the near and intermediate zones suffer the most.<br />

Variations of the distortions depending on the position of the lens in front of the eye<br />

Fitting 1 Fitting 2 Fitting 3<br />

Fitting conditions affect all areas of vision but particularly near vision<br />

Standard varifocal lens<br />

without fitting conditions<br />

Poor alignment of clear vision<br />

zones in relation to<br />

the natural eye path<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°<br />

uses five fitting parameters<br />

Good alignment of clear vision<br />

zones in relation to<br />

the natural eye path<br />

LENS<br />

Calculation<br />

P.d<br />

Vertex<br />

Tilt<br />

Wrap<br />

F.Height<br />

Fitting Conditions<br />

o<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°<br />

High Resolution Vision with Fitting Conditions<br />

As fitting gradually moves away from the ‘standard measurements,’<br />

the performance of the lens gradually deteriorates.<br />

Pantoscopic angle (°)<br />

P1 P2 P3 P4 P5 P6<br />

-5 – -1° 0 – 4° 5 – 10° 11 – 15° 16 – 20° 21 – 25°<br />

To overcome the potential drop in performance of the lens, <strong>Essilor</strong> has<br />

included five fitting measurements to define accurately the position of the<br />

lens in front of the wearer’s eyes.<br />

By factoring these measurements into the design calculation of <strong>Physio</strong><br />

f-<strong>360</strong>° the areas of clear vision are aligned perfectly in relation to<br />

the wearers’ natural line of vision, from the distance zone through to<br />

intermediate through to near.<br />

Near vision point location<br />

Vertex (mm)<br />

V1 V2 V3 V4 V5 V6<br />

5-7 mm 8-10 11-13 14-16 17-19 20-22 mm<br />

PHY SIO<br />

f-<strong>360</strong>°<br />

1.7 mm<br />

Wrap angle (°)<br />

7 mm<br />

2,5 mm<br />

To achieve perfect alignment, the exact position of the near vision zone is<br />

tailored to the five measurements. Vertically, the position can vary between<br />

15-18mm, with the horizontal inset varying between 1.7 & 7mm.<br />

This exact positioning ensures the wearer no longer needs to adopt<br />

unnatural postural adjustments for near vision tasks. Postural comfort and<br />

sharp crisp vision are achieved naturally without constraints.<br />

W1<br />

W2<br />

W3<br />

W4<br />

W5<br />

0–8°<br />

9–13°<br />

14–17°<br />

18–21°<br />

22–25°<br />

15 mm<br />

18 mm<br />

17 mm


<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°<br />

wavefront analysis<br />

The Wavefront technology allows analysis of lens performance.<br />

With <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° the beam of light passing through the lens is<br />

virtually aberration free for any direction of gaze whatever the<br />

fitting conditions.<br />

Near Vision<br />

Intermediate<br />

Vision<br />

Wavefront analyses:<br />

performance of <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° compared with a regular progressive lens<br />

Far Vision<br />

0° = Fitting cross<br />

Pupil diameter 6mm<br />

Intermediate Vision<br />

19.5° downward<br />

Pupil diameter 5mm<br />

Near Vision<br />

34.5° downward<br />

Pupil diameter 4mm<br />

Regular lens*<br />

34°<br />

Features Benefits<br />

Near vision point Tailored<br />

position plus vertical power<br />

control<br />

Tailored alignment plus<br />

axis control and unwanted<br />

astigmatism<br />

Coma control<br />

3x times lower HOA<br />

(Higher Order Aberrations)<br />

Astigmatism control<br />

unwanted astigmatism<br />

lowered by 30% and axes directed<br />

vertically<br />

Power control<br />

Defocus lowered<br />

by 30%<br />

* Analyses done with comparison to <strong>Varilux</strong> Panamic, with Plano, add 2.00 lenses<br />

for the following wearing conditions: Vertex 12mm, Pantoscopic angle 2°, Wrap angle 14°<br />

Better all round performance<br />

<strong>Varilux</strong> <strong>Physio</strong><br />

f- <strong>360</strong>°<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° builds on the success of <strong>Varilux</strong> <strong>Physio</strong> but thanks to<br />

the personalisation of the design according to fitting conditions, the areas<br />

of clear vision correspond each wearer’s exact requirements. <strong>Varilux</strong> <strong>Physio</strong><br />

f-<strong>360</strong>° delivers:<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° - new innovation at every distance<br />

Wider fields of vision plus<br />

greater visual and postural<br />

comfort<br />

Enhances width of field<br />

Distance vision Coma control Superior visual sharpness<br />

0°<br />

Off target<br />

Target<br />

Off target<br />

Off target<br />

Target<br />

Off target<br />

Off target<br />

Target<br />

Off target<br />

Material Range Coating Transitions<br />

Orma ® 1.5<br />

Airwear ® 1.59<br />

Ormix 1.6<br />

Stylis ® 1.67<br />

Lineis 1.74<br />

* Maximum tint class<br />

+6.00 to -10.00,<br />

cyls to 6.00<br />

+6.00 to -10.00,<br />

cyls to 6.00<br />

+8.00 to -12.00,<br />

cyls to 6.00<br />

+9.00 to -12.00,<br />

cyls to 6.00<br />

+13.00 to -18.00,<br />

cyls to 6.00<br />

Crizal Alizé ®<br />

& Crizal<br />

Alizé ® with<br />

Scotchgard<br />

Crizal<br />

Alizé ® with<br />

Scotchgard<br />

Dispensing <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°<br />

Who is <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°suitable for?<br />

• All wearers requiring the best visual performance<br />

• Wearers with a distance Rx greater than ± 3.00D<br />

• All wearers with astigmatism<br />

Measuring the five parameters<br />

Specific measuring devices are required to obtain the additional parameters<br />

required for <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° lenses. These measurements can be taken<br />

using either a fully automated instrument such like <strong>Essilor</strong>’s Visioffice unit<br />

that can prove invaluable in terms of the speed and accuracy, or by using<br />

a hand held device.<br />

<strong>Essilor</strong> has developed a comprehensive hand held measuring gauge<br />

specifically designed to assist the ordering of <strong>Physio</strong> f-<strong>360</strong>°.<br />

Range and availability<br />

<strong>Essilor</strong> Tints*<br />

(full)<br />

<strong>Essilor</strong>’s comprehensive measuring gauge<br />

<strong>Essilor</strong> Tints<br />

(grad)<br />

Silver Shadow<br />

Clean Touch<br />

Y 4 Y N<br />

Y 3 N N<br />

Y 4 Y N<br />

Y 4 Y N<br />

N N N N


57-02-006 03/08<br />

Where to order <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°<br />

<strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>°can be ordered directly from <strong>Essilor</strong>, online through <strong>Essilor</strong>der, through a <strong>Varilux</strong> Specialist<br />

Laboratory or a Wholesale Glazing Partner.<br />

<strong>Varilux</strong> Guarantee<br />

As with all <strong>Varilux</strong> lenses, <strong>Varilux</strong> <strong>Physio</strong> f-<strong>360</strong>° is covered by the <strong>Varilux</strong> guarantee scheme.<br />

<strong>Varilux</strong> is a registered trademark of <strong>Essilor</strong> International. <strong>Essilor</strong> Limited, Cooper Road, Thornbury, Bristol, BS35 3UW.<br />

www.essilor.co.uk General enquiries: 01454 417100

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!