Hotsy 965SS-1075SSE 97-6554 0605 - ETS Company Pressure ...
Hotsy 965SS-1075SSE 97-6554 0605 - ETS Company Pressure ...
Hotsy 965SS-1075SSE 97-6554 0605 - ETS Company Pressure ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
OPERATOR’S MANUAL PRESSURE WASHER<br />
8<br />
battery<br />
terminal<br />
12 volt<br />
battery<br />
battery box<br />
assembly & installation instructions<br />
2. Install the provided battery terminals as shown in<br />
figure 4.<br />
box strap<br />
battery<br />
box lid<br />
Figure 4 - Battery Installations/Connections<br />
responsibility<br />
installation<br />
black Wire from<br />
control box<br />
black Wire<br />
from voltage<br />
regulator<br />
red Wire from<br />
control box<br />
red Wire from<br />
voltage regulator<br />
3. To reduce the possibility of sparking attach the wires<br />
to the battery in the following order. Refer to figure<br />
4. First attach the red wire from the voltage regulator<br />
and the red wire from the control box to the positive<br />
“+” terminal of battery. Next, attach the black wire<br />
from the voltage regulator and the black wire from the<br />
control box to the negative “-” terminal of the battery.<br />
To disconnect the battery remove the wires in the<br />
opposite order as installed. Install battery box cover<br />
and fasten in place.<br />
The owner and/or user must have an understanding of<br />
the manufacturer’s operating instructions and warnings<br />
before using this <strong>Hotsy</strong> pressure washer. Warning information<br />
should be emphasized and understood. If the<br />
operator is not fluent in English, the manufacturer’s instructions<br />
and warnings shall be read to and discussed<br />
with the operator in the operator’s native language by<br />
the purchaser/owner, making sure that the operator<br />
comprehends its contents.<br />
Owner and/or user must study and maintain for future<br />
reference the manufacturers’ instructions.<br />
This manual should be considered a permanent part<br />
of the machine and should remain with it if machine<br />
is resold.<br />
When ordering parts, please specify model and serial<br />
number.<br />
getting started<br />
<strong>97</strong>-<strong>6554</strong> • HOTSY <strong>965SS</strong>-1075SS • REV. 5/06<br />
IMPORTANT: Proper initial installation of equipment<br />
will assure more satisfactory performance, longer<br />
service life, and lower maintenance cost.<br />
IMPORTANT: The use of a backflow preventer on<br />
the water supply hose is recommended and may be<br />
required by local code.<br />
The pressure washer should be run on a level surface<br />
and in a protected area where it is not readily influenced<br />
by outside forces such as strong winds, freezing<br />
temperatures, rain, etc. The pressure washer should<br />
be located to assure easy access for filling of fluids,<br />
adjustments and maintenance. Normal precautions<br />
should be taken by the operator to prevent moisture<br />
from reaching the pressure washer. It is recommended<br />
that a partition be made between the wash area and the<br />
pressure washer to prevent direct spray from the wand<br />
from coming in contact with the pressure washer. Moisture<br />
reaching the equipment will reduce the pressure washer’s<br />
service life. All installations must comply with the local<br />
codes covering such installations.<br />
venting<br />
CAUTION: All venting must be in accordance with applicable<br />
federal and state laws, and local ordinances.<br />
Consult local heating contractors.<br />
If the pressure washer is to be used in an enclosed area,<br />
a flue must be installed to vent burner and engine exhaust<br />
to the outside atmosphere. Be sure the flue is the same<br />
size as the burner exhaust vent on the pressure washer.<br />
See component identification for location. Poor draft<br />
will cause the pressure washer to soot and not operate<br />
properly. When selecting the location for installation,<br />
beware of poorly ventilated locations or areas where<br />
exhaust fans may cause an insufficient supply of oxygen.<br />
Proper combustion can only be obtained when there is a<br />
sufficient supply of oxygen available for the amount of fuel<br />
being burned. If it is necessary to install the machine in a<br />
poorly ventilated area, outside fresh air may have to be<br />
piped to the burner and a fan installed to bring sufficient<br />
air into the machine. Locate the pressure washer so<br />
that the flue will be as straight as possible and protrude<br />
through the roof at a proper height and location to provide<br />
adequate draft. This oil fired pressure washer must have<br />
a draft regulator installed in the flue (available from most<br />
heating contractors). A draft regulator will permit proper<br />
upward flow of exhaust flue gases.<br />
In addition, the pressure washer should never be operated<br />
in an enclosed area where high ambient temperatures<br />
exist. High ambient temperatures (above 100 o F) can<br />
cause engine oil failure and will greatly reduce the<br />
engine’s performance.