Technical data<br />
max. solder product format<br />
max. height of solder product<br />
Energy supply (V) 3+N+PE<br />
Power drawn<br />
Average power consumption with full load<br />
Average power consumption at standby<br />
Compressed oiled air<br />
Medium consumption ca.<br />
Medium basic filling quantity<br />
Heating-up time<br />
Aspiration power<br />
Cooling water inflow<br />
Cooling water reflow<br />
Cooling water pressure<br />
Cooling water (during operation with fresh water)<br />
Option:<br />
Cooling water/cooling system with compressor<br />
additional connection power<br />
<strong>VP</strong> <strong>1000</strong>-<strong>64</strong><br />
600 x 400 mm<br />
100 mm<br />
400 V / 50 Hz<br />
8,5 kW<br />
3,5 kWh<br />
2,0 kWh<br />
6 bar oil free<br />
10 - 15 g/h<br />
25 kg<br />
30 min<br />
200 m³/h<br />
1 x tube ½”<br />
1 x tube ½”<br />
2 – 4 bar<br />
10 – 18 °C<br />
2 KW<br />
1
Dimensions and weight<br />
Length A<br />
Width B (Basic model + loading station)<br />
Height C (at 935 mm load/unloading height;<br />
without signal mast)<br />
Load and unloading height (SMEMA)<br />
Aspiration diameter<br />
1.806 mm<br />
1.519 mm<br />
1.420 mm<br />
866 till 935 (depends on adjustment of mounting foot)<br />
100 mm<br />
Power- and consumption values are based on measurements of ASSCON Standard <strong>Soldering</strong> <strong>System</strong>s and on<br />
normal operational conditions. In particular consumption of reflow fluid depends on i.a. products use and respectively<br />
customer-specific production requirement. Therefore in individual cases variations of power- and consumption<br />
values like mentioned above can arise.<br />