Froom et al / LABORATORY-INITIATED REFLEX TESTING FOR AIHA<br />

Conclusion<br />

The labora<strong>to</strong>ry initiation of the workup ensured recommended<br />

medical practices, probably saved physician visits,<br />

and, in some patients, led <strong>to</strong> more timely diagnosis and appropriate<br />

treatment. Our findings support the use of reflex labora<strong>to</strong>ry-initiated<br />

testing in patients with normocytic anemia.<br />

Further studies are warranted <strong>to</strong> determine whether our findings<br />

can be extrapolated <strong>to</strong> other settings.<br />

From the Central <strong>Labora<strong>to</strong>ry</strong> of Haifa and Western Galilee, Clalit<br />

Health Services, Nesher, Israel.<br />

Address reprint requests <strong>to</strong> Dr Froom: Hema<strong>to</strong>logy<br />

Labora<strong>to</strong>ries, Central <strong>Labora<strong>to</strong>ry</strong> of Haifa and Western Galilee,<br />

Clalit Health Services, Nesher, Israel.<br />

References<br />

1. Normocytic normochromic anemias other than hemolytic<br />

anemias. In: Wintrobe MW, Lee GR, Boggs DR, et al, eds.<br />

Clinical Hema<strong>to</strong>logy. 8th ed. Philadelphia, PA: Lea and Febiger;<br />

1981:677-724.<br />

2. Beutler E. Production and destruction of erythrocytes. In:<br />

Beutler E, Lichtman MA, Coller BS, et al, eds. Williams<br />

Hema<strong>to</strong>logy. 6th ed. New York, NY: McGraw-Hill; 2001:356.<br />

3. Van Houte AJ, Bartels PC, Schoorl M, et al. Methodologydependent<br />

variations in reticulocyte counts using a manual<br />

and two different flow cy<strong>to</strong>metric procedures. Eur J Clin Chem<br />

Clin Biochem. 1994;32:859-863.<br />

132 Am J Clin Pathol 2005;124:129-132<br />

132 DOI: 10.1309/CFEECW31UYLHUJQG<br />

4. Nobes PR, Carter AB. Reticulocyte counting using flow<br />

cy<strong>to</strong>metry. J Clin Pathol. 1990;43:675-678.<br />

5. Kojima K, Niri M, Se<strong>to</strong>guchi K, et al. An au<strong>to</strong>mated<br />

op<strong>to</strong>electronic reticulocyte counter. Am J Clin Pathol.<br />

1989;92:57-61.<br />

6. Van den Bossche J, Devreese K, Malfait R, et al. Reference<br />

intervals for a complete blood count determined on different<br />

au<strong>to</strong>mated haema<strong>to</strong>logy analyzers: Abx Pentra 120 Retic,<br />

Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000, and<br />

Bayer Advia 120. Clin Chem Lab Med. 2002;40:69-73.<br />

7. Buttarello M, Bulian F, Venudo A, et al. <strong>Labora<strong>to</strong>ry</strong> evaluation<br />

of the Miles H.3 au<strong>to</strong>mated reticulocyte counter: a<br />

comparative study with manual reference method and Sysmex<br />

R-1000. Arch Pathol Lab Med. 1995;119:1141-1148.<br />

8. Nobes PR, Carter AB. Reticulocyte counting using flow<br />

cy<strong>to</strong>metry. J Clin Pathol. 1990;43:675-678.<br />

9. Hegde UM, Gordon-Smith EDC, Worlledge SM.<br />

Reticulocy<strong>to</strong>penia and absence of red cell au<strong>to</strong> antibodies in<br />

au<strong>to</strong>immune hemolytic anemia: analysis of 109 cases. Br Med<br />

J. 1977;2:1444-1447.<br />

10. Liesveld JL, Rowe JM, Lichtman MA. Variability of the<br />

erythropoietic response in au<strong>to</strong>immune hemolytic anemia.<br />

Blood. 1987;69:820-826.<br />

11. Packman CH. Acquired hemolytic anemia due <strong>to</strong> warmreacting<br />

au<strong>to</strong>antibodies. In Beutler E, Lichtman MA, Coller<br />

BS, et al, eds. Williams Hema<strong>to</strong>logy. 6th ed. New York, NY:<br />

McGraw-Hill; 2001:641.<br />

© American Society for Clinical Pathology

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!