Application data<br />

Standards<br />

IEC 60034­1<br />

Insulation<br />

Class H<br />

Temperature rise<br />

Frames 112­180: Class F<br />

Frames 200­280: Class H<br />

Vibration class and balance<br />

<strong>LAK</strong> 4000 motors follow IEC<br />

60034­14 with vibration class A<br />

as standard . Grade B is available<br />

on request . The motors are balanced<br />

with half key as standard .<br />

Overload capacity<br />

<strong>LAK</strong> 4112­4280:<br />

1 .6 x FLT for 15 sec . every 5<br />

minutes<br />

1 .8 x FLC for 30 sec . every 30<br />

minutes<br />

Terminal box position<br />

<strong>LAK</strong> 4112­4180:<br />

Standard: On right side of the<br />

motor (facing d­end) .<br />

Mounting of terminal box on top<br />

or left side on request .<br />

<strong>LAK</strong> 4200­4280:<br />

Standard: On top of the motor .<br />

Mounting of terminal box on<br />

either side of the motor on<br />

request .<br />

Blower position<br />

Standard: On top of the motor at<br />

the non­drive end .<br />

Other positions on request .<br />

Blower is supplied without filter<br />

as standard .<br />

Filter on request .<br />

Bearings<br />

Grease lubricated ball bearings<br />

on D­end as standard .<br />

For belt drive please contact our<br />

sales offices .<br />

Painting<br />

The standard <strong>LAK</strong> surface finish<br />

has excellent corrosion<br />

resistance properties . The<br />

standard colour of <strong>LAK</strong> motors is<br />

blue according to Munsell 8B<br />

4 .5/3 .25 (similar to RAL 5024) .<br />

Heat exchangers<br />

Air/water (IC86W):<br />

Air/water exchangers are especially<br />

recommended for polluted<br />

environment .<br />

Standard is for clean water .<br />

For corrosive water, please<br />

contact T­T <strong>Electric</strong> .<br />

Position on top of the motor<br />

as standard . Water connection<br />

flanges at right hand side<br />

(facing D­end) .<br />

Max . water pressure 10 PSI<br />

Max . inlet water temperature<br />

25°C . A water temperature rise<br />

of 8­10°C must be expected .<br />

<strong>LAK</strong> 4132­4180:<br />

Fan motor at N­end .<br />

<strong>LAK</strong> 4200­4280:<br />

Fan motor at D­end .<br />

A constant speed fan circulates<br />

the internal cooling air . A polyamide<br />

filter is provided to prevent<br />

circulation of carbon dust .<br />

For motors with low loads or a<br />

low incoming water temperature,<br />

a temperature regulator is<br />

recommended to avoid condensation<br />

in the cooling air circuit<br />

and to minimize water consumption<br />

.<br />

6<br />

Air/air (IC666):<br />

Detailed heat exchanger information on request.<br />

Air/air heat exchangers are<br />

recommended where water is<br />

not available for cooling purposes<br />

.<br />

The output of a motor with air/air<br />

exchanger will be approximately<br />

20% lower compared to cooling<br />

forms IC06/17/37/86W .<br />

<strong>LAK</strong> 4132­4280:<br />

Position: On top of the motor as<br />

standard .<br />

Two constant speed fans at top<br />

of the heat exchanger to provide<br />

air circulation for the outer and<br />

inner circuits .<br />

A polyamid filter is provided to<br />

prevent circulation of carbon<br />

dust .