SIZE<br />
SQ.MM<br />
CLASS<br />
OF<br />
CONDUCTOR<br />
RT OF<br />
BEDDING<br />
MM<br />
<strong>Multicore</strong> <strong>Armoured</strong> <strong>LSZH</strong> (<strong>Copper</strong>)<br />
XLPE/<strong>LSZH</strong>/SWA/<strong>LSZH</strong> (COPPER) BS6724 & IEC60502<br />
<strong>Multicore</strong> plain annealed copper conductor to IEC60228, XLPE insulated to IEC60502/<strong>LSZH</strong> extruded bedded to<br />
IEC60502/ Steel wire armoured to IEC60502/<strong>LSZH</strong> sheathed to IEC60502 600/1000 volts grade to BS6724 Fire<br />
performance to IEC60754, flame propagation to IEC60332 & smoke emissions to BSEN61034-2<br />
Applications: Power cable suitable for power networks, where fire & emission of smoke and toxic fumes create a<br />
serious potential threat<br />
NINETEEN CORE: REF 694/16 XWL<br />
1.5<br />
2.5<br />
4<br />
2<br />
2<br />
2<br />
1.0<br />
1.0<br />
1.0<br />
DIAMETER<br />
OVER<br />
BEDDING<br />
MM<br />
17.3<br />
19.3<br />
22.3<br />
TWENTY TWO CORE : REF 694/22 XWL<br />
1.5<br />
2.5<br />
4<br />
2<br />
2<br />
2<br />
1.0<br />
1.0<br />
1.0<br />
20.3<br />
22.7<br />
26.3<br />
DIAMETER<br />
OF<br />
ARMOUR<br />
WIRE<br />
MM<br />
TWENTY SEVEN CORE : REF 694/27 XWL<br />
1.5<br />
2.5<br />
4<br />
2<br />
2<br />
2<br />
1.0<br />
1.0<br />
1.0<br />
20.7<br />
23.2<br />
26.9<br />
THIRTY CORE : REF 694/30 XWL<br />
1.5<br />
2.5<br />
2<br />
2<br />
1.0<br />
1.0<br />
21.5<br />
24.1<br />
THIRTY SEVEN : REF 694/37 XWL<br />
1.5<br />
2.5<br />
2<br />
2<br />
1.0<br />
1.0<br />
FORTY CORE: REF 694/40 XWL<br />
1.5<br />
2.5<br />
2<br />
2<br />
1.0<br />
1.0<br />
23.3<br />
26.1<br />
24.3<br />
27.7<br />
FORTY EIGHT : REF 694/48 XWL<br />
1.5<br />
2.5<br />
2<br />
2<br />
1.0<br />
1.0<br />
26.7<br />
30.4<br />
Operating temperature: Maximum 90°C.<br />
Minimum bending -20°C<br />
Minimum bending radius:<br />
1.5 sq.mm - 16 sq.mm - 8 x overall diameter<br />
25 sq.mm and above - 8 x overall diameter<br />
Conductor identification:<br />
Two Core - Brown & Blue<br />
Three Core - Brown, Black & Grey<br />
Four Core - Brown, Grey, Blue & Black<br />
Five Core & above - Numbered cores.<br />
1.25<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
2.0<br />
DIAMETER<br />
OVER<br />
ARMOUR<br />
MM<br />
19.9<br />
22.6<br />
25.6<br />
23.6<br />
26.0<br />
29.6<br />
24.0<br />
26.5<br />
30.2<br />
24.8<br />
27.4<br />
26.6<br />
29.4<br />
27.6<br />
31.8<br />
30.0<br />
34.5<br />
APPROX<br />
OVERALL<br />
DIAMETER<br />
MM<br />
22.2<br />
26.1<br />
29.3<br />
26.1<br />
29.7<br />
33.5<br />
26.7<br />
30.2<br />
34.4<br />
28.5<br />
31.3<br />
29.2<br />
33.8<br />
31.5<br />
35.9<br />
33.9<br />
38.8<br />
WEIGHT<br />
KG/KM<br />
1120<br />
1570<br />
2050<br />
1560<br />
1930<br />
2530<br />
1630<br />
2050<br />
2740<br />
1730<br />
2200<br />
1970<br />
2540<br />
2080<br />
2970<br />
2390<br />
3430<br />
BATT<br />
CABLES<br />
PART<br />
NUMBER<br />
55451<br />
55363<br />
55051<br />
-<br />
-<br />
-<br />
55504<br />
55353<br />
55231<br />
-<br />
-<br />
55505<br />
55355<br />
-<br />
-<br />
55506<br />
55508<br />
BW<br />
INDOOR<br />
GLAND<br />
SIZE<br />
25<br />
25<br />
32<br />
32<br />
32<br />
40<br />
32<br />
32<br />
40<br />
32<br />
32<br />
32<br />
40<br />
32<br />
40<br />
40<br />
40<br />
Insulation thickness: Refer to Two core (6942XWL)<br />
GLAND<br />
KIT<br />
PART<br />
NUMBER<br />
88346<br />
88346<br />
88283<br />
88283<br />
88283<br />
88284<br />
88283<br />
88283<br />
88284<br />
88283<br />
88283<br />
88283<br />
88284<br />
88283<br />
88284<br />
88284<br />
88284<br />
Conductor Stranding: Class 2 stranded copper:<br />
2 circular or circular compacted conductors.<br />
2* shaped or circular conductors or circular compacted<br />
conductors.<br />
2S shaped conductors.<br />
(Dimensions and weights based on circular.)<br />
For approximate conductor and armour resistance, and<br />
percentage conductivity, refer to technical section D<br />
Combustion characteristics: HCL emission 0.5% in accordance<br />
with BSEN50267-1Common test methods for cables under fire condi-<br />
For current ratings, refer to Table 4E4A<br />
tions. Tests on gases evolved during combustion of materials from<br />
cables. Apparatus<br />
BW Brass indoor glands.<br />
BSEN50267-2-1:Common test methods for cables under fire condi-<br />
For a full specification of type BW glands, refer to Section C Page194<br />
tions. Tests on gases evolved during combustion of materials from<br />
Other gland types suitable, BW SOLO (LSF), CW (Indoor/Outdoor),<br />
cables. Procedures. Determination of the amount of halogen acid gas<br />
CW SOLO (LSF)E1W (outdoor) & E1FW ( Flameproof) types.<br />
Complete cables comply with the requirements of fire test<br />
For further details on these other gland types, refer to Section C .<br />
www.batt.co.uk BSEN50266-1:2001 (previously BS4066 Part 3)<br />