24.10.2012 Views

L Multicore Armoured LSZH (Copper) - Batt Cables

L Multicore Armoured LSZH (Copper) - Batt Cables

L Multicore Armoured LSZH (Copper) - Batt Cables

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SIZE<br />

SQ.MM<br />

CLASS<br />

OF<br />

CONDUCTOR<br />

RT OF<br />

BEDDING<br />

MM<br />

<strong>Multicore</strong> <strong>Armoured</strong> <strong>LSZH</strong> (<strong>Copper</strong>)<br />

XLPE/<strong>LSZH</strong>/SWA/<strong>LSZH</strong> (COPPER) BS6724 & IEC60502<br />

<strong>Multicore</strong> plain annealed copper conductor to IEC60228, XLPE insulated to IEC60502/<strong>LSZH</strong> extruded bedded to<br />

IEC60502/ Steel wire armoured to IEC60502/<strong>LSZH</strong> sheathed to IEC60502 600/1000 volts grade to BS6724 Fire<br />

performance to IEC60754, flame propagation to IEC60332 & smoke emissions to BSEN61034-2<br />

Applications: Power cable suitable for power networks, where fire & emission of smoke and toxic fumes create a<br />

serious potential threat<br />

NINETEEN CORE: REF 694/16 XWL<br />

1.5<br />

2.5<br />

4<br />

2<br />

2<br />

2<br />

1.0<br />

1.0<br />

1.0<br />

DIAMETER<br />

OVER<br />

BEDDING<br />

MM<br />

17.3<br />

19.3<br />

22.3<br />

TWENTY TWO CORE : REF 694/22 XWL<br />

1.5<br />

2.5<br />

4<br />

2<br />

2<br />

2<br />

1.0<br />

1.0<br />

1.0<br />

20.3<br />

22.7<br />

26.3<br />

DIAMETER<br />

OF<br />

ARMOUR<br />

WIRE<br />

MM<br />

TWENTY SEVEN CORE : REF 694/27 XWL<br />

1.5<br />

2.5<br />

4<br />

2<br />

2<br />

2<br />

1.0<br />

1.0<br />

1.0<br />

20.7<br />

23.2<br />

26.9<br />

THIRTY CORE : REF 694/30 XWL<br />

1.5<br />

2.5<br />

2<br />

2<br />

1.0<br />

1.0<br />

21.5<br />

24.1<br />

THIRTY SEVEN : REF 694/37 XWL<br />

1.5<br />

2.5<br />

2<br />

2<br />

1.0<br />

1.0<br />

FORTY CORE: REF 694/40 XWL<br />

1.5<br />

2.5<br />

2<br />

2<br />

1.0<br />

1.0<br />

23.3<br />

26.1<br />

24.3<br />

27.7<br />

FORTY EIGHT : REF 694/48 XWL<br />

1.5<br />

2.5<br />

2<br />

2<br />

1.0<br />

1.0<br />

26.7<br />

30.4<br />

Operating temperature: Maximum 90°C.<br />

Minimum bending -20°C<br />

Minimum bending radius:<br />

1.5 sq.mm - 16 sq.mm - 8 x overall diameter<br />

25 sq.mm and above - 8 x overall diameter<br />

Conductor identification:<br />

Two Core - Brown & Blue<br />

Three Core - Brown, Black & Grey<br />

Four Core - Brown, Grey, Blue & Black<br />

Five Core & above - Numbered cores.<br />

1.25<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

1.6<br />

2.0<br />

DIAMETER<br />

OVER<br />

ARMOUR<br />

MM<br />

19.9<br />

22.6<br />

25.6<br />

23.6<br />

26.0<br />

29.6<br />

24.0<br />

26.5<br />

30.2<br />

24.8<br />

27.4<br />

26.6<br />

29.4<br />

27.6<br />

31.8<br />

30.0<br />

34.5<br />

APPROX<br />

OVERALL<br />

DIAMETER<br />

MM<br />

22.2<br />

26.1<br />

29.3<br />

26.1<br />

29.7<br />

33.5<br />

26.7<br />

30.2<br />

34.4<br />

28.5<br />

31.3<br />

29.2<br />

33.8<br />

31.5<br />

35.9<br />

33.9<br />

38.8<br />

WEIGHT<br />

KG/KM<br />

1120<br />

1570<br />

2050<br />

1560<br />

1930<br />

2530<br />

1630<br />

2050<br />

2740<br />

1730<br />

2200<br />

1970<br />

2540<br />

2080<br />

2970<br />

2390<br />

3430<br />

BATT<br />

CABLES<br />

PART<br />

NUMBER<br />

55451<br />

55363<br />

55051<br />

-<br />

-<br />

-<br />

55504<br />

55353<br />

55231<br />

-<br />

-<br />

55505<br />

55355<br />

-<br />

-<br />

55506<br />

55508<br />

BW<br />

INDOOR<br />

GLAND<br />

SIZE<br />

25<br />

25<br />

32<br />

32<br />

32<br />

40<br />

32<br />

32<br />

40<br />

32<br />

32<br />

32<br />

40<br />

32<br />

40<br />

40<br />

40<br />

Insulation thickness: Refer to Two core (6942XWL)<br />

GLAND<br />

KIT<br />

PART<br />

NUMBER<br />

88346<br />

88346<br />

88283<br />

88283<br />

88283<br />

88284<br />

88283<br />

88283<br />

88284<br />

88283<br />

88283<br />

88283<br />

88284<br />

88283<br />

88284<br />

88284<br />

88284<br />

Conductor Stranding: Class 2 stranded copper:<br />

2 circular or circular compacted conductors.<br />

2* shaped or circular conductors or circular compacted<br />

conductors.<br />

2S shaped conductors.<br />

(Dimensions and weights based on circular.)<br />

For approximate conductor and armour resistance, and<br />

percentage conductivity, refer to technical section D<br />

Combustion characteristics: HCL emission 0.5% in accordance<br />

with BSEN50267-1Common test methods for cables under fire condi-<br />

For current ratings, refer to Table 4E4A<br />

tions. Tests on gases evolved during combustion of materials from<br />

cables. Apparatus<br />

BW Brass indoor glands.<br />

BSEN50267-2-1:Common test methods for cables under fire condi-<br />

For a full specification of type BW glands, refer to Section C Page194<br />

tions. Tests on gases evolved during combustion of materials from<br />

Other gland types suitable, BW SOLO (LSF), CW (Indoor/Outdoor),<br />

cables. Procedures. Determination of the amount of halogen acid gas<br />

CW SOLO (LSF)E1W (outdoor) & E1FW ( Flameproof) types.<br />

Complete cables comply with the requirements of fire test<br />

For further details on these other gland types, refer to Section C .<br />

www.batt.co.uk BSEN50266-1:2001 (previously BS4066 Part 3)<br />

battindustrial.sales@batt.co.uk<br />

L<br />

109

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!