ENGLISH<br />

30<br />

INSTALLER INSTRUCTIONS<br />

IMPORTANT: Always place the gasket between the hob fitting and the connection<br />

pipe.<br />

• If using a stainless steel flexible pipe, it must be installed so that it does not<br />

come in contact with any part of the cabinet, but passes through an unoccupied<br />

area where its entire length can be inspected. Maximum extension of the flexible<br />

pipe must be less than 2 metres.<br />

• The gas fitting is the type with a 1/2” gas ISO R7 tapered thread.<br />

After connecting the appliance to the gas supply network always verify fittings<br />

seal using a soapy solution.<br />

VERIFYING THE SEAL USING NAKED FLAMES IS ABSOLUTELY PROHIBITED.<br />

The cooker hob is tested for methane gas G20 (2H) at a pressure of<br />

20 mbar. For supplying with other types of gas, see the Adapting to the different<br />

types of gas table [Page 31]<br />

8.1 Connection to liquid gas<br />

Use a pressure regulator and realise connection on cylinder in compliance with the<br />

prescriptions established by the current Standards.<br />

Ensure the supply pressure respects the values indicated in the table<br />

Adapting to different types of gasses [Page 31]. In this case also, connection<br />

must be carried out with copper rigid pipe or with stainless steel flexible pipe with<br />

continuous wall.<br />

9. Room ventilation<br />

IMPORTANT: The appliance can only be installed in rooms that are permanently<br />

ventilated, as required by standards in force.