6<br />
Options and<br />
Technical Data<br />
Non-Clogging Recessed<br />
Impeller Design<br />
<strong>ERPN</strong>-O Semi Open<br />
Design with Replaceable<br />
Front Wear Plate<br />
Inducer<br />
A high specific speed, axial flow<br />
pumping device, an inducer<br />
provides significant improvement<br />
in suction performance by<br />
reducing NPSHR.<br />
The <strong>ERPN</strong>-M range of sealless<br />
process pumps is the solution<br />
for applications where leakagefree<br />
pumping of hazardous,<br />
toxic, explosive or ultra-high<br />
valuable liquids is required, and<br />
any emissions or leakage due<br />
<strong>ERPN</strong> Range Chart<br />
TDH - 50 Hz<br />
m 3 /h<br />
gpm<br />
ft m<br />
300<br />
800<br />
600 200<br />
500<br />
400<br />
300 100<br />
80<br />
200<br />
60<br />
50<br />
40<br />
100<br />
30<br />
80<br />
60 20<br />
50<br />
40<br />
30 10<br />
8<br />
20<br />
6<br />
5<br />
15<br />
m3 /h<br />
gpm<br />
<strong>ERPN</strong> – MAG Drive<br />
6<br />
8<br />
10<br />
1<br />
2<br />
2<br />
5<br />
6<br />
8<br />
10<br />
3<br />
2 Pole<br />
4 Pole<br />
4<br />
20<br />
5<br />
6<br />
30<br />
8<br />
40<br />
10<br />
50<br />
60<br />
80<br />
20<br />
100<br />
30<br />
40<br />
200<br />
50<br />
60<br />
300<br />
80<br />
400<br />
100<br />
500<br />
600<br />
3<br />
4<br />
20<br />
5<br />
6<br />
30<br />
8<br />
40<br />
10<br />
50<br />
60<br />
80<br />
20<br />
100<br />
30<br />
40<br />
200<br />
50<br />
60<br />
300<br />
80<br />
400<br />
100<br />
500<br />
600<br />
to mechanical seal failure is<br />
unacceptable. Safety features<br />
such as temperature probe<br />
(thermocouple), pressure switch<br />
and secondary containment seal<br />
are part of the standard scope<br />
of supply.<br />
Flow Rate - 60 Hz<br />
Flow Rate - 50 Hz<br />
200<br />
800<br />
1000<br />
200<br />
800<br />
1000<br />
300<br />
400<br />
500<br />
600<br />
300<br />
2000<br />
400<br />
500<br />
600<br />
2000<br />
800<br />
1000<br />
1600<br />
3000<br />
4000<br />
5000<br />
6000<br />
3000<br />
800<br />
1000<br />
1300<br />
4000<br />
5000<br />
ft m<br />
400<br />
1000<br />
300<br />
800<br />
600 200<br />
500<br />
400<br />
300 100<br />
80<br />
200<br />
60<br />
50<br />
40<br />
100<br />
30<br />
80<br />
60 20<br />
50<br />
40<br />
30 10<br />
8<br />
20<br />
7<br />
<strong>Pump</strong> Division<br />
<strong>API</strong> Material<br />
Combinations<br />
• S-5 Carbon steel with<br />
carbon steel internals<br />
• S-6 Carbon steel with<br />
12% chrome internals<br />
• S-8 Carbon steel with<br />
316 SS internals<br />
• C-6 12% chrome with<br />
12% chrome internals<br />
• A-8 316 SS with 316 SS<br />
internals<br />
• D-1 Duplex with duplex<br />
internals<br />
In addition the <strong>ERPN</strong><br />
is also available in low<br />
temperature carbon<br />
steel and super duplex<br />
stainless steel.<br />
Baseplate Options<br />
• Drain pan design<br />
– Welded and fabricated<br />
carbon steel<br />
– Sloping drain pan<br />
with drain connection<br />
• Drain rim design<br />
– Drain rim provided<br />
along baseplate<br />
perimeter<br />
– Drain pan provided<br />
below complete unit<br />
TDH - 60 Hz