27.10.2013 Views

CME256 Ice Machine - Parts Town

CME256 Ice Machine - Parts Town

CME256 Ice Machine - Parts Town

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

This parts list contains service part information for 8<br />

basic models, plus 4 different electrical configurations.<br />

The complete model number will be needed to<br />

identify the correct part.<br />

Model Series Changes (code at end of model number)<br />

• C series - changes to the front & side panels<br />

D series - changes to the top panel and to the<br />

compressor starting components<br />

E series - new side panels and 2 TXVs with<br />

check valves for the CME506<br />

F series - new water cooled condensers<br />

H series - color change<br />

Electrical Codes are located at the end of the model<br />

number (voltage/hertz/phase):<br />

-1 is 115/60/1<br />

-32 is 208-230/60/1<br />

-3 is 208-230/60/3<br />

-6 is 250/50/1<br />

November 2007<br />

Page 1<br />

Electrical Components Common to All <strong>Machine</strong>s:<br />

Inlet water valve<br />

Water sensor<br />

Discharge line sensor<br />

Controller<br />

<strong>Ice</strong> sensor/bin controls<br />

Water level sensor<br />

Unique Electrical Components<br />

Compressor and related starting components<br />

Contactor (single / three phase)<br />

Fan motor<br />

Water pump<br />

Transformer<br />

Hot gas valve<br />

Other Unique parts include: side panels, electrical,<br />

refrigeration and some water system items.<br />

TABLE OF CONTENTS<br />

Cabinet · · · · · · · · · · · · · · · · · · · ·<br />

Interior Structure & Controls · · · · · · · · ·<br />

<strong>CME256</strong> Air Cooled Refrigeration · · · · · ·<br />

PAGE 2<br />

PAGE 3<br />

PAGE 4<br />

A - C Series <strong>CME256</strong> and CME506 Air Cooled Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 24<br />

A - C Series Water Cooled Single Phase Schematic<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 25<br />

CME506 A-DSeries Air Cooled Refrigeration PAGE 5<br />

CME506 E-HSeries Air Cooled Refrigeration PAGE 6<br />

A - C Series <strong>CME256</strong> and CME506 Water Cooled Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 26<br />

CME656 Air Cooled Refrigeration · · · · · ·<br />

CME806 Air Cooled Refrigeration · · · · · ·<br />

Water System Components · · · · · · · · · ·<br />

PAGE 7<br />

PAGE 8<br />

PAGE 9<br />

A - C Series CME656 or CME806 Air Cooled Single<br />

Phase Wiring Diagram · · · · · · · · · · · · PAGE 27<br />

A - C Series CME656 Water Cooled Single Phase Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 28<br />

<strong>CME256</strong> Water Cooled Refrigeration · · · · · PAGE 10<br />

CME506 A-DSeries Water Cooled Refrigeration<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 11<br />

CME506 E-HSeries Water Cooled Refrigeration<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 12<br />

CME656 Water Cooled Refrigeration · · · · · PAGE 13<br />

CME806 Water Cooled Refrigeration · · · · · PAGE 14<br />

A - H Series Three Phase Air Cooled Schematic Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 29<br />

A - C Series CME656 Air Cooled Three Phase Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 30<br />

A - H Series CME656 Three Phase Water Cooled<br />

Schematic Diagram · · · · · · · · · · · · · · PAGE 31<br />

A - C Series CME656 Three Phase Water Cooled Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 32<br />

Compressors and Electrical Components for <strong>CME256</strong> and<br />

CME506 · · · · · · · · · · · · · · · · · · · · PAGE 15<br />

D thru H Series CME506 50 Hz Air Cooled Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 33<br />

Compressors and Electrical Components for CME656 and<br />

CME806 · · · · · · · · · · · · · · · · · · · · PAGE 16<br />

D thru H Series CME506 50 Hz Water Cooled Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 34<br />

HTB555 <strong>Ice</strong> Storage Bin · · · · · · · · · · · PAGE 17<br />

D thru H Series Single Phase 60 Hz Schematic Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 18<br />

D thru H Series, 115 volt <strong>CME256</strong> and CME506 Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 19<br />

D thru H Series CME656 or CME806 Single Phase Wiring<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 20<br />

D thru H Series CME656 Three Phase Wiring Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 21<br />

D thru H Series, 230 volt, 60 Hz. <strong>CME256</strong> and CME506<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 22<br />

A - C Series Single Phase Air Cooled Schematic Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 23<br />

D thru H Series CME656 or CME806 50 Hz Air Cooled<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 35<br />

D thru H Series CME656 or CME806 50 Hz Water Cooled<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 36<br />

B or C Series 50 Hz Water Cooled CME506 Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 37<br />

B or C Series, 50 Hz Air Cooled CME656 and CME806<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 38<br />

B or C Series, 50 Hz Water Cooled CME656 and CME806<br />

Diagram · · · · · · · · · · · · · · · · · · · · PAGE 39<br />

B or C Series, 50 Hz Air Cooled CME506 Diagram<br />

· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 40<br />

D thru H Series, 50 Hz <strong>CME256</strong> Diagram · · PAGE 41


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

8<br />

9<br />

11<br />

7 6<br />

November 2007<br />

Page 2<br />

2 1<br />

Item Part<br />

Number Number Description<br />

1 A35963-021 Right side panel, grey w/ louvers<br />

A35963-022 Right side panel, stainless steel w/ louvers - fits all Air Cooled<br />

A37071-021 Right side panel, painted w/out louvers (water cooled only)<br />

A37071-022 A - D series right side panel, stainless steel without louvers (water cooled only)<br />

A38126-021 E - H series right side panel, w/out louvers for water cooled only<br />

2 02-3659-01 Top insulation<br />

3 02-3797-21 C series Front panel kit, gray plastic, includes trim strip & emblems<br />

03-1733-01 Strike (for C to H series panel, SS or plastic)<br />

A37167-001 Front panel kit, SS, replaces gray plastic or SS, includes item 10a (for A series)<br />

A37488-031 C to H series Front panel kit, stainless steel, includes trim strip & emblems<br />

3a 15-0808-01 Emblem for ss panel (Scotsman); 03-0271-00 is the speed nut for emblem<br />

3b 15-0792-02 Emblem for C to H series front panel, (CM 3 )<br />

4 03-1735-01 Screw for trim strip (for C to H series)<br />

03-1404-12 Sheet metal screw for plastic front panel (for A series)<br />

03-1419-22 Sheet metal screw for ss front panel<br />

5 02-1875-03 Panel bumper/hole plug<br />

6 03-1531-01 Sheet metal screw<br />

7 A35962-021 Left side panel, grey enamel with louvers<br />

A35962-022 Left side panel, stainless steel with louvers<br />

A37070-021 Left side panel, grey enamel without louvers (water cooled only)<br />

A37070-022 A - D series left side panel, stainless steel without louvers (water cooled only)<br />

A38127-021 E - H series left side panel, w/out louvers for water cooled only<br />

8 02-3485-01 Air filter, air cooled only<br />

9 A35965-001 Top panel, grey enamel, order item 2 also<br />

A35965-002 Top panel, stainless steel, order item 2 also<br />

02-3822-21 Top panel, plastic, fits all, original to H series<br />

10a 02-3663-01 Evaporator cover, use began Feb. 1997. Fits A and B series<br />

02-3796-01 Insulation for above cover<br />

02-3663-20 Evap cover w/ ins for C-Hseries<br />

11 03-1423-06 Speed nut for panel screws<br />

12 03-1733-02 Catch<br />

5<br />

Cabinet<br />

13<br />

4<br />

13 A37326-001 Filter bracket<br />

14 02-3794-31 Trim strip.<br />

03-1731-02 is the push nut for trim strip<br />

12<br />

10<br />

3<br />

3b<br />

3a<br />

4<br />

14


9<br />

26<br />

19<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

20<br />

21<br />

18<br />

8 7<br />

Item Part<br />

6<br />

Number Number Description<br />

1 11-0540-21 Bin Control Sensor (set)<br />

2 02-3337-01 Cube deflector<br />

3 02-3339-01 Stand pipe<br />

02-3610-01 Stand pipe adjusting nut<br />

4 02-3360-01 Reservoir washer<br />

5 13-0617-56 O-ring<br />

6 02-3338-01 Drain tube & fittings<br />

7 03-1404-18 Screw<br />

8 A36298-001 Left side channel<br />

9 03-1531-01 Screw<br />

10 A36297-001 Right side channel<br />

11 13-0906-01 Plastic inlet water hose,<br />

21" req. order 2 units - not used after Sept. 1996<br />

12 03-1645-01 Screw<br />

13 03-1691-01 Nylon screw<br />

14 02-3340-01 Reservoir cover<br />

15 12-2548-01 Inlet water valve<br />

16 13-0674-02<br />

unit<br />

Tubing, 9" req., order 1<br />

17 02-3443-01 Water fitting for hose<br />

16-1020-01 Water fitting for copper<br />

18 02-0179-05 Clamp<br />

19 13-0903-01 Bumper for side panels<br />

Interior Structure & Controls<br />

22<br />

7<br />

23<br />

10<br />

Note: Item 25 mounts to Item 1.<br />

Item 1 must have rectangular<br />

mounting tabs. All units after 9/96<br />

were mfg. with rectangular tabs.<br />

11 12<br />

18<br />

24<br />

17<br />

9<br />

November 2007<br />

Page 3<br />

27<br />

16<br />

7<br />

15<br />

5<br />

13<br />

14<br />

4<br />

20 16-0997-01 Inlet water fitting for hose<br />

16-1019-01 Inlet water fitting for copper<br />

21 16-0701-07 Mounting flange<br />

22 12-2838-23 AutoIQ controller<br />

23 12-2644-21 Low voltage harness A-Cseries<br />

12-2782-21 Low volt harness, D + series 60 Hz<br />

12-2782-23 Low volt harness, D + series 50 Hz<br />

24 12-2618-01 Hi volt harness, w fan control A series<br />

12-2476-01 Hi volt harness for w/o fan control A-C<br />

12-2678-01 Hi volt harness for 50 Hz models A-C<br />

12-2784-21 Hi volt harness for D + series 60 Hz.<br />

12-2786-21 Hi volt harness for D + series 50 Hz.<br />

25 02-3657-01 Cascading shield, used on<br />

CME806, 656 and 506 after 2/97<br />

26 A36460-001 Back panel assy (ac)<br />

A36460-003 Back panel assy (wc)<br />

27 A35959-001 Hi voltage box cover<br />

28 A36457-001 Foamed base<br />

1<br />

3<br />

25<br />

2<br />

28


12<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

<strong>CME256</strong> Air Cooled Refrigeration<br />

11<br />

8<br />

7<br />

See Page 15<br />

9<br />

Item Part<br />

Number Number Description<br />

10<br />

1 18-8745-01 Condenser<br />

2 03-1531-01 Screw<br />

For models with a fan control switch:<br />

3 A36031-001 Shroud<br />

The part number of the fan control pressure switch is: 11-0508-21<br />

4 A36668-001 Motor bracket<br />

5 18-8503-01 Fan blade<br />

6 18-5505-01 Fan motor for 115 volt, 60 Hz<br />

18-5505-12 Fan motor for 230 volt, 50 Hz<br />

18-5505-11 Fan motor for 230 volt, 60 Hz<br />

7 12-2471-01 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

8 16-1009-22 TXV<br />

02-4406-01 Insulation for TXV<br />

9 02-3319-01 Dryer<br />

10 A36734-020 Evaporator<br />

11 16-0832-21 Access valve<br />

11a 16-0832-03 Port cap<br />

11b 16-0832-02 Stem cap<br />

12 02-3410-21 Temp sensor, incl. water temp<br />

sensor & clip<br />

03-1711-01 Sensor clip<br />

13 16-1063-02 Hot gas valve strainer (not shown)<br />

November 2007<br />

Page 4<br />

4<br />

5<br />

6<br />

4<br />

2<br />

3<br />

1


11<br />

10<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

CME506 A-DSeries Air Cooled Refrigeration<br />

12 13<br />

Item Part<br />

See Page 15<br />

Number Number Description<br />

1 18-8744-01 Condenser<br />

2 03-1531-01 Screw<br />

3 A35967-001 Shroud<br />

4 A36668-001 Motor bracket<br />

5 18-8503-01 Fan blade<br />

6 18-5505-01 Fan motor for 115 volt, 60 Hz.<br />

18-5505-12 Fan motor for 230 volt, 50 Hz.<br />

18-5505-11 Fan motor for 230 volt, 60 Hz<br />

7 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

8 A36734-020 Evaporator<br />

9 16-1017-21 TXV (was 16-0867-21, they are interchangeable)<br />

02-4406-01 Insulation for TXV<br />

10 02-3410-21 Temp. sensor, includes water temp. & clip<br />

11 02-3319-02 Dryer<br />

12 16-0832-21 Access valve<br />

12a 16-0832-03 Port cap<br />

12b 16-0832-02 Stem cap<br />

7<br />

9<br />

15<br />

September 2009<br />

Page 5<br />

4<br />

5<br />

6<br />

4<br />

8<br />

For models with a fan control switch:<br />

The part number of the fan control pressure switch is: 11-0508-21<br />

13 16-0843-03 Distributor assembly<br />

14 16-1063-01 Hot gas valve strainer (not shown)<br />

15 03-1645-01 Screw<br />

2<br />

3<br />

1


8<br />

7<br />

12<br />

See Page 15<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

CME506 E-HSeries Air Cooled Refrigeration<br />

Item Part<br />

Number Number Description<br />

1 18-8866-02 Condenser - E Series & up<br />

2 03-1531-01 Screw<br />

3 A35967-001 Shroud<br />

4 A36668-001 Motor bracket<br />

5 18-8503-01 Fan blade<br />

6 18-5505-01 Fan motor for 115 volt, 60 Hz.<br />

18-5505-12 Fan motor for 230 volt, 50 Hz.<br />

18-5505-11 Fan motor for 230 volt, 60 Hz<br />

7 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

8 A36734-020 Evaporator<br />

9 16-1009-22 TXV - only for E series & up<br />

02-4405-01 Insulation for TXV<br />

10 02-3410-21 Temp. sensor, includes water<br />

temp. sensor. & clip<br />

14<br />

10<br />

9<br />

15<br />

9<br />

13<br />

16<br />

11<br />

August 2008<br />

Page 6<br />

4<br />

5<br />

6<br />

4<br />

Item Part<br />

Number Number Description<br />

11 02-3319-01 Dryer<br />

12 16-0832-21 Access valve<br />

12a 16-0832-03 Port cap<br />

12b 16-0832-02 Stem cap<br />

13 16-1071-01 Check valve<br />

14 16-1063-01 Hot gas valve strainer<br />

15 16-1095-01 Restrictor<br />

16 03-1645-01 Screw<br />

2<br />

3<br />

1


12<br />

11<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

13<br />

CME656 Air Cooled Refrigeration<br />

10<br />

7<br />

Item Part<br />

See Page 16<br />

9<br />

Number Number Description<br />

1 18-8739-01 Condenser<br />

2<br />

3<br />

4<br />

03-1531-01<br />

A35967-001<br />

A36668-001<br />

Screw<br />

Shroud<br />

Motor bracket<br />

8<br />

For models with a fan control switch:<br />

The part number of the fan control pressure switch is: 11-0508-21<br />

5 18-8503-01 Fan blade<br />

6 18-5505-11 Fan motor for 60 Hz.<br />

18-5505-12 Fan motor for 50 Hz.<br />

7 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

8 A36734-020 Evaporator<br />

9 16-1076-21 TXV (interchangeable with all prior)<br />

02-4406-01 Insulation for TXV<br />

10 16-0843-02 Distributor and tubes<br />

11 02-3410-21 Temperature sensor, includes water temp sensor & clip<br />

03-1711-01 Clip<br />

12 02-3319-02 Dryer<br />

13 16-0832-21 Access valve<br />

13a 16-0832-03 Port cap<br />

15 03-1645-01 Screw<br />

13b 16-0832-02 Stem cap<br />

14 16-1063-01 Hot gas valve strainer (not shown)<br />

15<br />

November 2007<br />

Page 7<br />

4<br />

5<br />

6<br />

4<br />

2<br />

3<br />

1


12 14<br />

11<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

CME806 Air Cooled Refrigeration<br />

13<br />

7<br />

10<br />

Item Part<br />

See Page 16<br />

Number Number Description<br />

1<br />

2<br />

18-8739-01<br />

03-1531-01<br />

Condenser<br />

Screw<br />

8<br />

3 A35967-001 Shroud<br />

4 A36668-001 Motor bracket<br />

5 18-8503-01 Fan blade<br />

6 18-8829-01 Fan motor for 60 Hz.<br />

18-8829-02 Fan motor for 50 Hz.<br />

7 12-2471-24 Hot gas valve complete w/coil<br />

12-2719-23 Hot gas valve coil only<br />

12-2733-30 Hot gas valve repair kit (no body, no coil)<br />

8 A36734-020 Evaporator<br />

9 16-1076-21 TXV (interchangeable with prior valve)<br />

02-4406-01 Insulation for TXV<br />

10 16-0843-02 Distributor and tubes<br />

11 02-3410-21 Temperature sensor, includes water temp sensor & clip<br />

03-1711-01 Clip<br />

12 02-3319-02 Dryer<br />

13<br />

13a<br />

16-0832-21<br />

16-0832-03<br />

Access valve<br />

Port cap<br />

15 03-1645-01 Screw<br />

13b 16-0832-02 Stem cap<br />

14 16-1063-01 Hot gas valve strainer<br />

November 2007<br />

Page 8<br />

9<br />

15<br />

4<br />

5<br />

6<br />

4<br />

2<br />

3<br />

1


5<br />

4<br />

Single Evaporator<br />

Models<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

1<br />

3<br />

2<br />

Water System Components<br />

1<br />

3<br />

6<br />

Item Part<br />

Two Evaporator Models<br />

Number Number Description<br />

1 02-2527-01 Water distributor<br />

2 A30926-001 Distributor manifold<br />

3 13-0898-02 Tubing grommet<br />

4<br />

5<br />

02-3361-01<br />

02-3410-21<br />

Water discharge tube for single evaporator models<br />

Water temperature sensor includes disch. temp. sensor<br />

13<br />

6 no number Cable tie<br />

7 02-3405-01 Inlet Tee<br />

15<br />

8<br />

13-0840-01<br />

02-3336-01<br />

Rubber plug<br />

Water distributor tube for<br />

double evaporator models<br />

12<br />

9 02-3383-01<br />

02-3383-02<br />

Float stem, 1 evaporator model*<br />

Float stem, 2 evaporator model*<br />

10 11-0539-51 Float (water level) sensor<br />

11 02-3388-04 Front pump bracket for 12-2586 type pump<br />

12 02-3388-05 Rear pump bracket for 12-2586 type pump<br />

13 12-2506-01 Harness<br />

14 02-3341-01 Float<br />

15 12-2586-21 <strong>CME256</strong>-1 (115 volt) pump<br />

12-2586-27 CME506-1 (115 volt) pump<br />

12-2586-26 <strong>CME256</strong>-6 or -32 (208-230 volt),<br />

12-2586-23 CME506-6 or 32 (208-230 volt),<br />

CME656 or CME806 (208-230 volt) pump. 50 or 60 Hz.<br />

* Not adjustable after 2/97. Then 1 evap model white, 2 evap. model grey.<br />

August 2008<br />

Page 9<br />

5<br />

6<br />

8<br />

3<br />

7<br />

1<br />

11<br />

1<br />

7<br />

9<br />

10<br />

14


8<br />

9<br />

10<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

<strong>CME256</strong> Water Cooled Refrigeration<br />

11<br />

See Page 15<br />

Item Part<br />

Number Number Description<br />

1 03-1403-15 Screw<br />

2 11-0478-01 Water regulating valve<br />

3 A36440-001 Back cover<br />

4 03-1645-01 Screw<br />

5 18-3306-25 Condenser, A thru E series<br />

18-8871-21 Condenser, F series<br />

6 02-3319-01 Dryer<br />

7 A36734-020 Evaporator<br />

8 02-3410-21 Hi temperature sensor,<br />

includes water temp sensor & clip<br />

03-1711-01 Clip for sensor<br />

9 11-0501-21 Hi pressure cut out<br />

10 16-0832-21 Access valve<br />

10a 16-0832-03 Port cap<br />

10b 16-0832-02 Stem cap<br />

11 16-1009-22 TXV 1/4 ton<br />

02-4406-01 Insulation for TXV<br />

12<br />

6<br />

November 2007<br />

Page 10<br />

3<br />

5<br />

4<br />

7<br />

14<br />

Item Part<br />

Number Number Description<br />

12 12-2471-01 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

13 16-1063-02 Hot gas valve strainer<br />

(not shown)<br />

14 A31828-001 Fitting<br />

1<br />

2


10<br />

11<br />

12<br />

See Page 15<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

9<br />

CME506 A-DSeries Water Cooled Refrigeration<br />

8<br />

Item Part<br />

Number Number Description<br />

7<br />

1 03-1403-15 Screw<br />

2 11-0478-01 Water regulating valve<br />

3 A36440-001 Back cover<br />

4 03-1645-01 Screw<br />

5 18-3306-25 Condenser<br />

6 02-3319-02 Dryer<br />

7 A36734-020 Evaporator<br />

8 16-1017-21 TXV 1/2 ton (was 16-0867-21) For A-DSeries only<br />

02-4406-01 Insulation for TXV<br />

9 16-0843-03 Distributor and tubes<br />

10 02-3410-21 Hi temperature sensor, includes water temperature sensor<br />

03-1711-01 Clip for sensor<br />

11 11-0501-21 Hi pressure cut out<br />

12 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

13 16-0832-21 Access valve<br />

13a 16-0832-03 Port cap<br />

14 16-1063-01 Hot gas valve strainer, not shown<br />

15 A31828-001 Fitting<br />

6<br />

November 2007<br />

Page 11<br />

5<br />

3<br />

4<br />

15<br />

1<br />

2


7<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

CME506 E-HSeries Water Cooled Refrigeration<br />

See Page 15<br />

4<br />

Item Part<br />

Number Number Description<br />

1 16-1063-01 Hot gas valve strainer<br />

2 11-0478-01 Water regulating valve<br />

3 16-1071-01 Check valve<br />

4 16-0832-21 Access valve<br />

16-0832-03 Port cap<br />

5 18-3306-25 Condenser, E series<br />

18-8871-21 Condenser, F&Hseries<br />

03-1645-01 Screw to mount condenser (not shown)<br />

6 02-3319-01 Dryer<br />

7 A36734-020 Evaporator<br />

8 16-1009-22 TXV for E Series & up<br />

02-4405-01 Insulation for TXV<br />

9 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

10 02-3410-21 Hi temperature sensor, includes water temperature sensor<br />

03-1711-01 Clip for sensor<br />

11 11-0501-21 Hi pressure cut out<br />

12 A31828-001 Fitting<br />

13 16-1095-01 Restrictor<br />

August 2008<br />

Page 12<br />

1<br />

10<br />

11<br />

8<br />

9<br />

13<br />

3<br />

5<br />

2<br />

6


10<br />

11<br />

12<br />

13<br />

See Page 16<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

9<br />

Item Part<br />

Number Number Description<br />

1 03-1403-15 Screw<br />

2 11-0478-01 Water regulating valve<br />

3 A36440-001 Back cover<br />

4 03-1645-01 Screw<br />

5 18-6900-25 Condenser, A-Eseries<br />

18-8874-21 Condenser, F series<br />

6 02-3319-02 Dryer<br />

7 A36734-020 Evaporator<br />

8 16-1076-21 TXV ( interchangeable<br />

w/prior valve)<br />

02-4406-01 Insulation for TXV<br />

9 16-0843-02 Distributor and tubes<br />

10 02-3410-21 Hi temperature sensor,<br />

includes water temperature sensor<br />

03-1711-01 Clip for sensor mounting<br />

CME656 Water Cooled Refrigeration<br />

8<br />

6<br />

14<br />

November 2007<br />

Page 13<br />

5<br />

7<br />

3<br />

4<br />

16<br />

Item Part<br />

Number Number Description<br />

11 11-0501-21 Hi pressure cut out<br />

12 12-2471-22 Hot gas valve w/coil<br />

12-2719-23 Hot gas valve coil only<br />

13 16-0832-21 Access valve<br />

13a 16-0832-03 Port cap<br />

14 16-0874-01 Receiver<br />

15 16-1063-01 Hot gas valve strainer,<br />

not shown<br />

16 A31828-001 Fitting<br />

1<br />

2


10<br />

11<br />

12<br />

13<br />

9<br />

See Page 16<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

Item Part<br />

Number Number Description<br />

1 03-1403-15 Screw<br />

2 11-0478-01 Water regulating valve<br />

3 A36440-001 Back cover<br />

4 03-1645-01 Screw<br />

5 18-6900-21 Condenser, A-Eseries<br />

18-8874-21 Condenser, F&Hseries<br />

6 02-3319-02 Dryer<br />

7 A36734-020 Evaporator<br />

8 16-1076-21 TXV (interchangeable with<br />

prior valve)<br />

8a 02-4406-01 Insulation for TXV<br />

9 16-0843-02 Distributor and tubes<br />

10 02-3410-21 Hi temperature sensor,<br />

includes water temperature sensor<br />

03-1711-01 Clip for sensor mounting<br />

11 11-0501-21 Hi pressure cut out<br />

CME806 Water Cooled Refrigeration<br />

8<br />

6<br />

November 2007<br />

Page 14<br />

7<br />

5<br />

3<br />

4<br />

15<br />

Item Part<br />

Number Number Description<br />

12 12-2471-24 Hot gas valve complete<br />

w/coil<br />

12-2719-23 Hot gas valve coil only<br />

12-2733-30 Hot gas valve repair kit, no<br />

coil, no body<br />

13 16-0832-21 Access valve<br />

13a 16-0832-03 Port cap<br />

14 16-1063-01 Hot gas valve strainer, not<br />

shown<br />

15 A31828-001 Fitting<br />

1<br />

2


Grommet,<br />

Sleeve<br />

-6B, C, D, E, F<br />

series<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

Compressors and Electrical Components for <strong>CME256</strong> and CME506<br />

Model <strong>CME256</strong> CME506<br />

Voltage/Hz 115/60 208-230/60 230/50 115/60 208-230/60 230/50<br />

Phase Single Single Single Single Single Single<br />

Compressor 18-8720-21* 18-8838-23* 18-8838-22 18-8721-21* 18-8839-23* 18-8721-22<br />

PTCR - D thru F<br />

series only<br />

<strong>CME256</strong> or<br />

CME506<br />

Transformer<br />

Compressor<br />

18-8835-01 18-8835-01 18-8835-01 18-8835-01 18-8835-01 18-8835-01<br />

Start Relay** 18-1903-44 not used not used 18-1903-50 not used 18-1903-29<br />

Start Capacitor** 18-1901-49 not used 18-2200-35 18-1901-03 not used 18-1901-43<br />

Run Capacitor 18-1902-52 18-1902-17 not used 18-1902-45 18-1902-45 18-1902-30<br />

Overload 18-5700-50 18-8838-50 18-5700-55 18-8711-50 18-8839-50 18-8721-50<br />

Mounting Bolt 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20<br />

Sleeve 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27<br />

Washer 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07<br />

Grommet 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28<br />

Contactor 12-2469-01 12-2469-01 12-2469-01 12-2469-01 12-2469-01 12-2469-01<br />

Transformer A37231-001 A37217-001 12-2639-02 A37231-001 A37217-001 A37217-001<br />

* Includes starting components. All compressors include a drier. ** D thru F series uses PTCR<br />

Bolt<br />

Hi Voltage<br />

Harness<br />

Transformer<br />

Washer<br />

Relay, A-C<br />

Series<br />

Fuse Fuse Block Relay Relay Bracket<br />

12-2639-02 12-2678-21 12-2686-01 12-2687-01 12-2679-01 12-2680-01<br />

November 2007<br />

Page 15<br />

Contactor<br />

Start Capacitor<br />

A - C Series Only<br />

Run Capacitor


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

Compressor<br />

Bolt<br />

Grommet,<br />

Sleeve Washer<br />

November 2007<br />

Page 16<br />

Contactor<br />

Model CME656 CME806<br />

Run Capacitor<br />

Voltage/Hz 208-230/60 208-230/60 230/50 208-230/60 208-230/60 230/50<br />

Phase Single Three Single Single Three Single<br />

Compressor 18-8813-23* 18-8813-25 18-8813-27 18-8749-22* 18-8749-24 18-8749-27<br />

PTCR - D thru<br />

F series only<br />

18-8835-01 not used 18-8835-01 18-8835-01 not used 18-8835-01<br />

Start Relay** 18-1903-33 not used 18-1903-29 18-1903-46 not used 18-1903-33<br />

Start<br />

Capacitor**<br />

18-1901-15 not used 18-1901-52 18-1901-48 not used 18-1901-48<br />

Run Capacitor 18-1902-53 not used 18-1902-53 18-1902-55 not used 18-1902-55<br />

Overload internal internal internal internal internal internal<br />

Mounting Bolt 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20<br />

Sleeve 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27<br />

Washer 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07<br />

Grommet 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28<br />

Contactor 12-2469-01 12-2533-01 12-2469-01 12-2469-01 12-2533-01 12-2469-01<br />

Transformer A37217-001 A37217-001 A37217-001 A37217-001 A37217-001 A37217-001<br />

* Includes starting components. All compressors include a drier. ** D thru F series uses PTCR<br />

-6B, C, D, E, F<br />

series<br />

CME656 or<br />

CME806<br />

Compressors and Electrical Components for CME656 and CME806<br />

Transformer<br />

Hi Voltage<br />

Harness<br />

Transformer<br />

Relay, A-C<br />

Series<br />

Start Capacitor<br />

A - C Series Only<br />

Fuse Fuse Block Relay Relay Bracket<br />

12-2639-02 12-2678-21 12-2686-01 12-2687-01 12-2679-01 12-2680-01


7<br />

8<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

Item Part<br />

Number Number Description<br />

1 02-2380-02 Spacer<br />

2 02-3196-01 Hinge<br />

3 02-2806-01 Shoulder screw<br />

4 03-1539-09 E-ring<br />

5 19-0503-04 Gasket 9 ft. *<br />

6 02-3274-02 Door frame (grey)<br />

7 13-0909-01 Door gasket - 58" *<br />

8 A36481-022 Door, grey, includes #7.<br />

9 03-0727-11 Thumb screw<br />

10 A35637-001 Canopy<br />

11 A35640-001 Baffle<br />

12 02-2809-02 Drain top<br />

13 13-0617-09 O-ring<br />

14 02-3108-01 Drain bottom<br />

Not shown<br />

03-1404-07 Screw for drain bottom<br />

05-0586-01 Drain elbow<br />

02-0540-00 Scoop<br />

KLP2E Enamel leg kit<br />

* Order gasket by the foot.<br />

Optional: A35477-001 Scoop holder, not shown<br />

9<br />

HTB555 <strong>Ice</strong> Storage Bin<br />

6<br />

11<br />

10<br />

December 2003<br />

Page 17<br />

Door<br />

Frame<br />

(ref)<br />

Bin Liner<br />

(ref) 12<br />

14<br />

4<br />

13<br />

5<br />

2<br />

1<br />

3


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series Single Phase 60 Hz Schematic Diagram<br />

L1<br />

DISCHARGE<br />

TEMP.<br />

TRANSFORMER<br />

LINE<br />

24V<br />

HI PRESSURE<br />

CONTROL<br />

(WCONLY)<br />

ELECTRONIC CONTROL<br />

SUMP<br />

TEMP.<br />

BI N<br />

FULL<br />

X- MIT<br />

BIN<br />

FULL<br />

RCV.<br />

CONTACTOR T1 WATER<br />

PUMP<br />

COMPRESSOR<br />

N(115/60/1UNITS)<br />

L2 (230/60/ 1 UNITS)<br />

HOT GAS VALVE<br />

WATER VALVE<br />

November 2007<br />

Page 18<br />

CONTACTOR<br />

COI L<br />

WATE R<br />

LEVEL<br />

SENSOR<br />

PTCR<br />

RUN<br />

CAP.<br />

FAN<br />

MOTOR<br />

(AC ONLY)


17-2747-01<br />

BIN FULL<br />

TRANSMITTER<br />

BIN FULL<br />

RECIEVER<br />

LB<br />

DI SCHARGE<br />

TEMP.<br />

SENSOR<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series, 115 volt <strong>CME256</strong> and CME506 Wiring Diagram<br />

SUMP TEMP.<br />

SENSOR<br />

WATER<br />

LEVEL<br />

SENSOR<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

WATER<br />

MOT<br />

(ACONLY) MOT<br />

HOT GAS<br />

PUMP<br />

FAN<br />

GRAY<br />

SOLENOID<br />

SOLENOID<br />

O<br />

5<br />

4<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

5<br />

4<br />

3<br />

2<br />

1<br />

2 1<br />

3<br />

1 2 3 4 5 6 7 1 2 3 4<br />

8 9<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

O<br />

ELECTRONIC CONTR OL<br />

COMMUNICATIONS<br />

PORT<br />

CAUTION:<br />

USE COPPER CONDUCTORS ONLY<br />

BU<br />

BN<br />

W<br />

BK<br />

BK<br />

Y<br />

V<br />

HI PRESSURE<br />

CONTROL<br />

(WC ONLY)<br />

MOR E TH AN O NE D I S CO NN EC T ME AN S MA Y BE<br />

REQUI RED TO DI SCONNECT ALL POWER TO THI S UNI T.<br />

O<br />

LOAD<br />

W<br />

LI NE<br />

TRANSFORMER<br />

BK<br />

BK<br />

November 2007<br />

Page 19<br />

O<br />

W<br />

JUNCTION<br />

BOX<br />

W<br />

GROUND<br />

SCREW<br />

POWER SUPPLY<br />

S EE NAMEPL ATE FOR<br />

P ROP ER VOL TAGE REQUI RE MENTS<br />

A ND MAX I MUM F USE SI ZE<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

L1<br />

L2<br />

Y<br />

T1<br />

T2<br />

CONTACTOR<br />

EARTH GROUND<br />

C AUT I ON : P TCR WI LL BE HOT .<br />

C OMP RE S S OR MA Y N OT S T A RT I F<br />

P TCR I S NOT A LLOWED TO COOL.<br />

W/ R<br />

RUNWINDING<br />

STARTWINDING<br />

FUSITE<br />

BK<br />

R<br />

W<br />

W/ Y<br />

S<br />

C<br />

R<br />

PTCR<br />

RUN<br />

CAP<br />

BK<br />

W/ R<br />

BK Y R<br />

EXTERNAL<br />

PROTECTOR<br />

COMPRESSOR


17-2751-01<br />

BIN FULL<br />

TRANSMITTER<br />

BIN FULL<br />

RECIEVER<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME656 or CME806 Single Phase Wiring Diagram<br />

LB<br />

DI SCHARGE<br />

TEMP.<br />

SENSOR<br />

WATER<br />

MOT<br />

(ACONLY) MOT<br />

HOT GAS<br />

PUMP<br />

FAN<br />

GRAY<br />

SOLENOID<br />

SOLENOID<br />

SUMP TEMP.<br />

SENSOR<br />

WATER<br />

LEVEL<br />

SENSOR<br />

O<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

5<br />

4<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

5<br />

4<br />

3<br />

2<br />

1<br />

2 1<br />

6<br />

3<br />

1 2 3 4 5 6 7 1 2 3 4<br />

8 9<br />

7<br />

5<br />

4<br />

3<br />

2<br />

1<br />

O<br />

BU<br />

ELECTRONIC CONTR OL<br />

COMMUNICATIONS<br />

PORT<br />

BN<br />

W<br />

BK<br />

BK<br />

Y<br />

CAUTION:<br />

V<br />

USE COPPER CONDUCTORS ONLY<br />

HI PRESSURE<br />

CONTROL<br />

(WC ONLY)<br />

LOAD<br />

W<br />

BK<br />

O<br />

November 2007<br />

Page 20<br />

W<br />

BK<br />

BK/ W<br />

POWER SUPPLY<br />

SEE NAMEPLATE FOR<br />

P ROP ER VOL TAGE REQUI RE MENTS<br />

A ND MAX I MUM F USE SI ZE<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

GROUND<br />

SCREW<br />

MOR E TH AN ONE D I S CONN EC T ME AN S MA Y BE<br />

REQUI RED TO DI SCONNECT AL L POWER TO THI S UNI T.<br />

O<br />

LI NE<br />

TRANSFORMER<br />

JUNCTION<br />

BOX<br />

L1<br />

L2<br />

T2<br />

CONTACTOR<br />

EARTH GROUND<br />

C AUT I ON : P TCR WI LL BE HOT .<br />

C OMP RE S S OR MA Y N OT S T A RT I F<br />

P T C R I S N O T A L L O W E D T O C O O L .<br />

T1<br />

Y<br />

PROTECTOR<br />

INTERNAL<br />

COMPRESSOR<br />

TERMINAL BOX<br />

R<br />

BK<br />

W<br />

W/ Y<br />

W/ R<br />

PTCR<br />

RUN<br />

CAP<br />

C1 S2<br />

R3<br />

W/ R<br />

BK Y R


17-2757-01<br />

BIN FULL<br />

TRANSMITTER<br />

BIN FULL<br />

RECIEVER<br />

LB<br />

DI SCHARGE<br />

TEMP.<br />

SENSOR<br />

SUMP TEMP.<br />

SENSOR<br />

WATER<br />

LEVEL<br />

SENSOR<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME656 Three Phase Wiring Diagram<br />

O<br />

5<br />

4<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

5<br />

4<br />

3<br />

2<br />

1<br />

2 1<br />

3<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

USE COPPER CONDUCTORS ONLY<br />

WATER<br />

MOT<br />

(ACONLY) MOT<br />

HOT GAS<br />

PUMP<br />

FAN<br />

GRAY<br />

SOLENOID<br />

SOLENOID<br />

5<br />

4<br />

3<br />

2<br />

1<br />

O<br />

BU<br />

ELECTRONIC CONTR OL<br />

BN<br />

1 2 3 4 5 6 7 1 2 3 4<br />

8 9<br />

7<br />

6<br />

COMMUNICATIONS<br />

PORT<br />

CAUTION:<br />

W<br />

BK<br />

BK<br />

Y<br />

V<br />

HI PRESSURE<br />

CONTROL<br />

(WC ONL Y)<br />

W<br />

BK<br />

November 2007<br />

Page 21<br />

O<br />

W<br />

GROUND<br />

SCREW<br />

EARTH GROUND<br />

MOR E TH AN ONE D I S CONN EC T ME AN S MA Y BE<br />

REQUI RED TO DI SCONNECT ALL POWER TO THI S UNIT. LOAD<br />

O<br />

LI NE<br />

TRANSFORMER<br />

JUNCTION<br />

BOX<br />

BK<br />

BK<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

BK<br />

L1<br />

L2<br />

L3<br />

T1<br />

T2<br />

T3<br />

CONTACTOR<br />

POWER SUPPLY<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

Y<br />

PROTECTOR<br />

INTERNAL<br />

R<br />

BK<br />

W<br />

COMPRESSOR<br />

TERMINAL BOX<br />

R R R<br />

C1<br />

R3<br />

S2


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series, 230 volt, 60 Hz. <strong>CME256</strong> and CME506 Diagram<br />

November 2007<br />

Page 22


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series Single Phase Air Cooled Schematic Diagram<br />

November 2007<br />

Page 23


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series <strong>CME256</strong> and CME506 Air Cooled Wiring Diagram<br />

August 2006<br />

Page 24


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series Water Cooled Single Phase Schematic Diagram<br />

November 2007<br />

Page 25


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series <strong>CME256</strong> and CME506 Water Cooled Wiring Diagram<br />

November 2007<br />

Page 26


BIN FULL<br />

TRANSMITTER<br />

BIN FULL<br />

RECIEVER<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series CME656 or CME806 Air Cooled Single Phase Wiring Diagram<br />

A36659-001<br />

BU<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

SUMP TEMP.<br />

SENSOR<br />

WATER<br />

LEVEL<br />

SENSOR<br />

O<br />

1 2 3 4 5 6 7 1 2 3 4<br />

8 9<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

5<br />

4<br />

3<br />

2<br />

1<br />

3<br />

2<br />

1<br />

5<br />

4<br />

3<br />

2<br />

1<br />

O<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

USE COPPER CONDUCTORS ONLY<br />

WATER HOT GAS<br />

SOLENOID<br />

MOT<br />

PUMP<br />

O<br />

BU<br />

ELECTRONIC<br />

CONTROL<br />

COMMUNICATIONS<br />

PORT<br />

MOT<br />

FAN<br />

BN<br />

W/BU<br />

BK<br />

BK/W<br />

V<br />

R<br />

W/BN<br />

POTENTIAL RELAY<br />

LOAD<br />

5<br />

SOLENOID<br />

BU<br />

BK/W<br />

November 2007<br />

Page 27<br />

1<br />

2<br />

LINE<br />

TRANSFORMER<br />

O<br />

W<br />

JUNCTION<br />

BOX<br />

2<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK<br />

WIRE COLOR FOR 230/50/1 UNITS : BROWN<br />

2<br />

GROUND<br />

SCREW<br />

L1<br />

L2<br />

W/R<br />

BN<br />

Y/W<br />

EARTH GROUND<br />

POWER SUPPLY<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

Y<br />

PROTECTOR<br />

INTERNAL<br />

START<br />

CAP<br />

RUN<br />

CAP<br />

R/W<br />

BK Y R<br />

CAUTION:<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />

T1<br />

T2<br />

CONTACTOR<br />

R<br />

BK<br />

W<br />

COMPRESSOR<br />

TERMINAL BOX<br />

C1<br />

R3<br />

S2


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series CME656 Water Cooled Single Phase Wiring Diagram<br />

November 2007<br />

Page 28


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - H Series Three Phase Air Cooled Schematic Diagram<br />

November 2007<br />

Page 29


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series CME656 Air Cooled Three Phase Wiring Diagram<br />

November 2007<br />

Page 30


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - H Series CME656 Three Phase Water Cooled Schematic Diagram<br />

November 2007<br />

Page 31


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

A - C Series CME656 Three Phase Water Cooled Wiring Diagram<br />

November 2007<br />

Page 32


USE COPPER CONDUCTORS ONLY<br />

17-2749-01<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

O<br />

WATER HOT GAS<br />

MOT<br />

MOT<br />

PUMP FAN<br />

GRAY<br />

SOLENOID<br />

SOLENOID<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME506 50 Hz Air Cooled Diagram<br />

BN<br />

BN<br />

CAUTION: PTCR WILL BE HOT.<br />

BU/BN<br />

COMPRESSOR MAY NOT START IF<br />

BU<br />

BU/W<br />

L2<br />

TRANSFORMER<br />

L1<br />

PTCR IS NOT ALLOWED TO COOL.<br />

0<br />

O<br />

LB<br />

BU<br />

LI NE<br />

6 4<br />

6 4<br />

HOTGASVALVE<br />

24V<br />

0<br />

1 0<br />

1 0<br />

PTCR<br />

WATER VAL VE<br />

CONTROL RELAY 1 CONTROL RELAY 2<br />

FUSE<br />

O<br />

O<br />

CONTACTOR COIL<br />

V<br />

CONTROL REL AY 1 COIL<br />

Y<br />

CONTROL RELAY 2 COIL<br />

W/R<br />

W/Y<br />

W/BU<br />

T1<br />

L1<br />

V<br />

V<br />

BK<br />

W/BN<br />

SUMPTEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

L2 T2<br />

CONTACTOR<br />

FUSE<br />

(3A)<br />

4<br />

4 5 6 7 1 2 3<br />

8 9<br />

3<br />

2<br />

1<br />

W<br />

7<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

W/R<br />

November 2007<br />

Page 33<br />

WATER<br />

LEVEL<br />

SENSOR<br />

BIN<br />

BI N<br />

FULL<br />

X- MI T<br />

6<br />

FULL<br />

SUMP<br />

TEMP.<br />

5<br />

RCV.<br />

DISCHARGE<br />

TEMP.<br />

7 1<br />

8 2<br />

BK<br />

BK<br />

11 5<br />

12 6<br />

TRANSFORMER<br />

V<br />

4<br />

LOADLINE<br />

3<br />

2<br />

5<br />

BK Y R<br />

ELECTRONIC<br />

CONTROL<br />

1<br />

3<br />

2<br />

4<br />

BIN FULL<br />

TRANSMITTER<br />

1<br />

BU BN<br />

3<br />

2<br />

3<br />

CONTROL RELAY 2<br />

1<br />

GROUND<br />

SCREW<br />

5<br />

CONTROL RELAY 1<br />

4<br />

3<br />

2<br />

BIN FULL<br />

RECIEVER<br />

G/Y<br />

JUNCTION<br />

BOX<br />

2<br />

FAN<br />

MOTOR<br />

CONTACTOR T1 WATER<br />

PUMP<br />

FUSITE<br />

1<br />

1<br />

BK<br />

R<br />

COMMUNICATIONS<br />

PORT<br />

2<br />

1<br />

3<br />

C<br />

RUN<br />

EXTERNAL<br />

PROTECTOR<br />

COMPRESSOR<br />

BK<br />

WINDING<br />

POWER SUPPLY<br />

S<br />

R<br />

WATER<br />

LEVEL<br />

SENSOR<br />

START<br />

W<br />

WINDING<br />

EARTH GROUND<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SI ZE<br />

CAUTION:<br />

PTCR<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

REQUIRE D TO DISCONNECT ALL POWER TO THI S UNIT.<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

RUN<br />

CAP.<br />

COMPRESSOR


USE COPPER CONDUCTORS ONLY<br />

17-2750-01<br />

1 DA SHED LI NES INDICATEFI EL D WI RINGWHI CH MUST BE<br />

INSTALLEDIN ACCORDANCE WI THTHE NATI ONAL EL ECTRI CAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

O<br />

WATER HOT GAS<br />

MOT<br />

PUMP<br />

GRAY<br />

SOLENOI D<br />

SOLENOI D<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME506 50 Hz Water Cooled Diagram<br />

BN<br />

BU/BN<br />

BN<br />

BU/ W<br />

CAUTION: PTCR WILL BE HOT.<br />

OO<br />

COMPRESSOR MAY NOT START IF<br />

L2<br />

TRANSFORMER<br />

L1<br />

PTCR IS NOT ALLOWED TO COOL.<br />

LB<br />

LINE<br />

FOR USE ONLY<br />

ON AIR UNITS<br />

24V<br />

HOT GAS VALVE<br />

6 4<br />

PTCR<br />

WATER VALVE<br />

FUSE<br />

O<br />

1 0<br />

O<br />

CONTACTOR<br />

COIL<br />

V<br />

HI-PRESS<br />

CONTROL<br />

BU<br />

W/BU CONTROL<br />

RELAY<br />

O<br />

CONTROL RELAY COIL<br />

W/R<br />

W/Y<br />

W/BN<br />

T1<br />

L1<br />

V<br />

V<br />

BK<br />

SUMP TEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

L2 T2<br />

CONTACTOR<br />

FUSE<br />

(3A)<br />

4<br />

4 5 6 7 1 2 3<br />

8 9<br />

3<br />

2<br />

1<br />

Y<br />

W<br />

7<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

W/R<br />

November 2007<br />

Page 34<br />

WATER<br />

LEVEL<br />

SENSOR<br />

BIN<br />

FULL<br />

RCV.<br />

BIN<br />

FULL<br />

X-MIT<br />

SUMP<br />

TEMP.<br />

6<br />

5<br />

DISCHARGE<br />

TEMP.<br />

7 1<br />

8 2<br />

BK<br />

11 5<br />

12 6<br />

LOADLINE<br />

BK<br />

V<br />

ELECTRONIC<br />

CONTROL<br />

4<br />

5<br />

3<br />

2<br />

TRANSFORMER<br />

1<br />

BK Y R<br />

3<br />

4<br />

2<br />

BIN FULL<br />

TRANSMITTER<br />

1<br />

BU BN BN<br />

3<br />

3<br />

2<br />

1<br />

GROUND<br />

SCREW<br />

5<br />

2<br />

4<br />

BIN FULL<br />

RECIEVER<br />

CONTROL<br />

RELAY<br />

CONTACTOR T1 WATER<br />

PUMP<br />

JUNCTION<br />

BOX<br />

3<br />

G/Y<br />

Y<br />

2<br />

FUSITE<br />

1<br />

1<br />

BK<br />

R<br />

COMMUNICATIONS<br />

PORT<br />

C<br />

RUNWINDING<br />

3 2 1<br />

POWER SUPPLY<br />

HI PRESSURE<br />

CONTROL<br />

EXTERNAL<br />

PROTECTOR<br />

COMPRESSOR<br />

S<br />

BK<br />

R<br />

W<br />

STARTWINDING<br />

EARTH GROUND<br />

WATER<br />

LEVEL<br />

SENSOR<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

PTCR<br />

CAUTION:<br />

THIS UNIT MUST<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

BE GROUNDED.<br />

RUN<br />

CAP.<br />

REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />

COMPRESSOR


USE COPPER CONDUCTORS ONLY<br />

17-2753-01<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME656 or CME806 50 Hz Air Cooled Diagram<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

O<br />

WATER HOT GAS<br />

MOT<br />

MOT<br />

PUMP<br />

FAN<br />

GRAY<br />

SOLENOID<br />

SOLENOID<br />

BN<br />

C A U T I O N : P T C R W I L L BE H O T .<br />

BU/ BN<br />

BN<br />

BU/ W<br />

C O M P R E S S O R M A Y N O T STA R T I F<br />

P T C R I S N O T A L L O W E D T O C O O L .<br />

L2<br />

BU<br />

TRANSFORMER<br />

L1<br />

O<br />

O<br />

BU<br />

BU<br />

LINE<br />

6 4<br />

6 4<br />

24V<br />

HOT GAS VALVE<br />

O<br />

1 0<br />

1 0<br />

PTCR<br />

WAT ER VALVE<br />

CONT ROL RE LAY 1 CONT ROL RE LAY 2<br />

FUSE<br />

O<br />

CONTACTOR COI L<br />

V<br />

Y<br />

CONTROL REL AY 1 COI L<br />

O<br />

CONTROL REL AY 2 COI L<br />

W/ R<br />

W/ Y<br />

W/ BU<br />

T1<br />

L1<br />

V<br />

V<br />

BK<br />

W/ BN<br />

SUMPTEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

L2 T2<br />

CONTACTOR<br />

FUSE<br />

(3A)<br />

4<br />

4 5 6 7 1 2 3<br />

8 9<br />

3<br />

2<br />

1<br />

W<br />

7<br />

DI SCHARGE<br />

TEMP.<br />

SENSOR<br />

W/ R<br />

6<br />

November 2007<br />

Page 35<br />

WAT ER<br />

LEVEL<br />

SENSOR<br />

BI N<br />

FULL<br />

RCV.<br />

BI N<br />

FULL<br />

X- MI T<br />

SUMP<br />

TEMP.<br />

5<br />

DI SCHARGE<br />

TEMP.<br />

7 1<br />

8 2<br />

BK<br />

11 5<br />

12 6<br />

LOADLINE<br />

BK<br />

V<br />

4<br />

5<br />

3<br />

2<br />

TRANSFORMER<br />

ELECTRONI C<br />

CONTROL<br />

1<br />

BK Y R<br />

3<br />

1 2 4<br />

BIN FULL<br />

TRANSMITTER<br />

BU BN<br />

3<br />

2<br />

1 3<br />

CONTROL REL AY 2<br />

GROUND<br />

SCREW<br />

5<br />

CONTROL REL AY 1<br />

BIN FULL<br />

RECIEVER<br />

G/ Y<br />

JUNCTION<br />

BOX<br />

1 2 3 4 2<br />

FAN<br />

MOT OR<br />

CONTACTOR T1 WAT ER<br />

PUMP<br />

TERMINAL BOX<br />

PROTECTOR<br />

INTERNAL<br />

COMMUNICATIONS<br />

PORT<br />

1<br />

3 2 1<br />

R<br />

S2<br />

C1<br />

POWER SUPPLY<br />

BK<br />

EARTH GROUND<br />

WATER<br />

LEVEL<br />

SENSOR<br />

R3<br />

SEE NAMEPL ATE FOR<br />

PROPER VOL TAGE REQUI REMENTS<br />

AND MAXI MUM FUSE SI ZE<br />

PTCR<br />

W<br />

COMPRESSOR<br />

RUN<br />

CAP.<br />

CAUTION:<br />

MORE THAN ONE DI SCONNECT ME AN S MA Y BE<br />

REQUI RED TO DI SCONNECT AL L POWE R TO THI S UN I T .<br />

THIS UNIT MUST<br />

BE GROUNDED.<br />

COMPRESSOR


USE COPPER CONDUCTORS ONLY<br />

17-2754-01<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series CME656 or CME806 50 Hz Water Cooled Diagram<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

O<br />

WATER<br />

HOT GAS<br />

MOT<br />

PUMP<br />

GRAY<br />

SOLENOID SOLENOID<br />

C A U T I O N : P T C R W I L L B E H O T .<br />

C O M P R E S S O R M A Y N O T S T A R T I F<br />

BN<br />

BU/ BN<br />

P T C R I S N O T A L L O W E D T O C O O L .<br />

BN<br />

BU/ W<br />

OO<br />

L2<br />

TRANSFORMER<br />

L1<br />

FOR USE ONLY<br />

ON AI R UNI TS<br />

BU<br />

LINE<br />

24V<br />

HOT GAS VALVE<br />

4<br />

6<br />

PTCR<br />

WAT ER VALVE<br />

FUSE<br />

0<br />

1<br />

O<br />

O<br />

CONTACTOR<br />

COI L<br />

V<br />

HI - PRESS<br />

CONT ROL<br />

CONTROL<br />

REL AY<br />

W/ BU<br />

BU<br />

O<br />

CONTROL REL AY COI L<br />

W/ R<br />

W/ Y<br />

W/ BN<br />

L1 T1<br />

V<br />

V<br />

BK<br />

SUMPTEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

L2 T2<br />

FUSE<br />

(3A)<br />

Y<br />

CONTACTOR<br />

W<br />

1 2 3 45 6 7 12 3 4<br />

8<br />

9<br />

7<br />

November 2007<br />

Page 36<br />

BK<br />

LOADLINE 6<br />

7 1<br />

8 2<br />

11 5<br />

12<br />

TRANSFORMER<br />

DI SCHARGE<br />

TEMP.<br />

SENSOR<br />

WAT ER<br />

LEVEL<br />

SENSOR<br />

BI N<br />

FULL<br />

RCV.<br />

BI N<br />

FULL<br />

X- MI T<br />

W/ R<br />

BK<br />

6<br />

SUMP<br />

TEMP.<br />

DI SCHARGE<br />

TEMP.<br />

V<br />

ELECTRONI C<br />

CONTROL<br />

5<br />

1 23 4 5<br />

Y R<br />

BK<br />

4<br />

1 2 3<br />

BIN FULL<br />

TRANSMITTER<br />

BN BN<br />

BU<br />

3<br />

1 2 3<br />

TERMINAL BOX<br />

PROTECTOR<br />

INTERNAL<br />

GROUND<br />

SCREW<br />

2<br />

CONTROL<br />

REL AY<br />

G/ Y<br />

JUNCTION<br />

BOX<br />

Y<br />

1 2 34 5<br />

BIN FULL<br />

RECIEVER<br />

R<br />

S2<br />

C1<br />

WAT ER<br />

PUMP<br />

CONTACTOR T1<br />

BK<br />

COMMUNICATIONS<br />

PORT<br />

1<br />

3 21<br />

R3<br />

POWER SUPPLY<br />

HI PRESSURE<br />

CONTROL<br />

W<br />

COMPRESSOR<br />

EARTH GROUND<br />

WATER<br />

LEVEL<br />

SENSOR<br />

SEE NAMEPL ATE FOR<br />

PROPER VOL TAGE REQUI REMENTS<br />

AND MAXI MUM FUSE SI ZE<br />

PTCR<br />

CAUTION:<br />

MORE THAN ONE DI SCONNECT ME AN S MA Y BE<br />

THIS UNIT MUST<br />

RUN<br />

CAP.<br />

REQUI RED TO DI SCONNECT AL L POWE R TO THI S UN I T .<br />

BE GROUNDED.<br />

COMPRESSOR


1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

USE COPPER CONDUCTORS ONLY<br />

17-2484-01<br />

WATER HOT GAS<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

B or C Series 50 Hz Water Cooled CME506 Diagram<br />

O<br />

R<br />

MOT<br />

PUMP<br />

SOLENOID<br />

SOLENOID<br />

W/BN<br />

BN<br />

W/BU<br />

BU/W<br />

O<br />

L2<br />

TRANSFORMER<br />

L1<br />

O<br />

BU<br />

LINE<br />

CONTROL BOX<br />

POTENTIAL RELAY<br />

HOT GAS VALVE<br />

24V<br />

BN<br />

1<br />

5<br />

2 4<br />

WATER VALVE<br />

START<br />

CAP<br />

FUSE<br />

Y/W<br />

2<br />

1 0<br />

O<br />

CONTACTOR<br />

COIL<br />

HI-PRESS<br />

CONTROL<br />

BU<br />

BU CONTROL<br />

V<br />

BK<br />

RELAY<br />

O<br />

CONTROL RELAY COIL<br />

R/W<br />

T1<br />

L1<br />

BK/W<br />

BK<br />

BK/W<br />

SUMP TEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

4<br />

3<br />

4 5 6 7 1 2<br />

8 9<br />

3<br />

2<br />

1<br />

Y<br />

L2 T2<br />

CONTACTOR<br />

FUSE<br />

(3A)<br />

W<br />

7<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

November 2007<br />

Page 37<br />

1<br />

WATER<br />

LEVEL<br />

SENSOR<br />

BIN<br />

FULL<br />

RCV.<br />

BIN<br />

FULL<br />

X-MIT<br />

W/R<br />

7<br />

8<br />

SUMP<br />

TEMP.<br />

BK BK<br />

2<br />

6<br />

5<br />

DISCHARGE<br />

TEMP.<br />

ELECTRONIC<br />

CONTROL<br />

4<br />

6<br />

11 5<br />

12<br />

LOAD LINE<br />

V<br />

5<br />

3<br />

TRANSFORMER<br />

2<br />

BK Y R<br />

1<br />

3<br />

4<br />

2<br />

BIN FULL<br />

TRANSMITTER<br />

1<br />

BN BN<br />

3<br />

3<br />

2<br />

1<br />

GROUND<br />

SCREW<br />

5<br />

2<br />

4<br />

BIN FULL<br />

RECIEVER<br />

CONTROL<br />

RELAY<br />

G/Y<br />

JUNCTION<br />

BOX<br />

3<br />

Y<br />

2<br />

WATER<br />

PUMP<br />

CONTACTOR T1<br />

FUSITE<br />

1<br />

1<br />

1<br />

BK<br />

R<br />

COMMUNICATIONS<br />

PORT<br />

2<br />

C<br />

RUN WINDING<br />

HI PRESSURE<br />

CONTROL<br />

3<br />

POWER SUPPLY<br />

EXTERNAL<br />

PROTECTOR<br />

COMPRESSOR<br />

S<br />

BK<br />

R<br />

WATER<br />

LEVEL<br />

SENSOR<br />

W<br />

START WINDING<br />

EARTH GROUND<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

START<br />

CAP.<br />

POTENTIAL<br />

RELAY<br />

POTENTIAL<br />

RELAY COIL<br />

CAUTION:<br />

RUN<br />

CAP.<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />

COMPRESSOR<br />

THIS UNIT MUST<br />

BE GROUNDED.


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

B or C Series, 50 Hz Air Cooled CME656 and CME806 Diagram<br />

1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

USE COPPER CONDUCTORS ONLY<br />

17-2485-01<br />

HOT GAS<br />

MOT<br />

PUMP<br />

WATER<br />

O<br />

R<br />

MOT<br />

FAN<br />

SOLENOID SOLENOID<br />

W/BN<br />

BN/W<br />

W/BU<br />

BU/W<br />

O<br />

L1 TRANSFORMER<br />

L2<br />

LINE<br />

0<br />

0<br />

BK<br />

O<br />

BU<br />

BK<br />

CONTROL BOX<br />

6 4<br />

HOT GAS VALVE<br />

24V<br />

POTENTIAL RELAY<br />

5 1<br />

6 4<br />

1 0<br />

BN<br />

0<br />

1<br />

WATER VALVE<br />

START<br />

CAP<br />

Y/W<br />

CONTROL RELAY 2<br />

CONTROL RELAY 1<br />

BU<br />

FUSE<br />

2<br />

O<br />

CONTACTOR COIL<br />

BU<br />

V<br />

CONTROL RELAY 1 COIL<br />

CONTROL RELAY 2 COIL<br />

R/W<br />

L1 T1<br />

BK/W<br />

BK<br />

BN<br />

BK/W<br />

SUMP TEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

FUSE<br />

(3A)<br />

L2 T2<br />

CONTACTOR<br />

1 2 3 4 5 6 7 1 2 3 4<br />

8<br />

9<br />

November 2007<br />

Page 38<br />

Y<br />

W<br />

7<br />

1<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

WATER<br />

LEVEL<br />

SENSOR<br />

BIN<br />

FULL<br />

RCV.<br />

BIN<br />

FULL<br />

X-MIT<br />

W/R<br />

7<br />

8<br />

SUMP<br />

TEMP.<br />

BK BK<br />

2<br />

6<br />

DISCHARGE<br />

TEMP.<br />

6<br />

11 5<br />

12<br />

LOAD LINE<br />

V<br />

5<br />

TRANSFORMER<br />

1 2 3 4 5<br />

Y R<br />

BK<br />

ELECTRONIC<br />

CONTROL<br />

4<br />

1 2 3<br />

BIN FULL<br />

TRANSMITTER<br />

BN BN<br />

3<br />

1 2 3<br />

CONTROL RELAY 2<br />

TERMINAL BOX<br />

PROTECTOR<br />

INTERNAL<br />

GROUND<br />

SCREW<br />

CONTROL RELAY 1<br />

2<br />

R<br />

C1 S2<br />

1 2 3 4 5<br />

BIN FULL<br />

RECIEVER<br />

G/Y<br />

JUNCTION<br />

BOX<br />

FAN<br />

MOTOR<br />

WATER<br />

PUMP<br />

CONTACTOR T1<br />

BK<br />

COMMUNICATIONS<br />

PORT<br />

1<br />

1 2 3<br />

R3<br />

POWER SUPPLY<br />

WATER<br />

LEVEL<br />

SENSOR<br />

COMPRESSOR<br />

W<br />

EARTH GROUND<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

START<br />

CAP.<br />

POTENTIAL<br />

RELAY<br />

POTENTIAL<br />

RELAY COIL<br />

CAUTION:<br />

RUN<br />

CAP.<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />

COMPRESSOR<br />

THIS UNIT MUST<br />

BE GROUNDED.


1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />

INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />

CODE AND ALL STATE AND LOCAL CODES.<br />

USE COPPER CONDUCTORS ONLY<br />

17-2593-01<br />

<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

B or C Series, 50 Hz Water Cooled CME656 and CME806 Diagram<br />

WATER HOT GAS<br />

O<br />

R<br />

MOT<br />

PUMP<br />

SOLENOID<br />

SOLENOID<br />

W/BN<br />

BN/W<br />

W/BU<br />

BU/W<br />

O<br />

L2<br />

TRANSFORMER<br />

L1<br />

FOR USE ONLY<br />

ON AIR UNITS<br />

O<br />

BU<br />

LINE<br />

CONTROL BOX<br />

POTENTIAL RELAY<br />

HOT GAS VALVE<br />

24V<br />

BN<br />

1<br />

5<br />

6 4<br />

WATER VALVE<br />

START<br />

CAP<br />

FUSE<br />

Y/W<br />

2<br />

1 0<br />

O<br />

CONTACTOR<br />

COIL<br />

HI-PRESS<br />

CONTROL<br />

BU<br />

BU BU CONTROL<br />

V<br />

BK<br />

RELAY<br />

O<br />

CONTROL RELAY COIL<br />

R/W<br />

BN<br />

T1<br />

L1<br />

BK/W<br />

BK<br />

BK/W<br />

SUMP TEMP.<br />

SENSOR<br />

ELECTRONIC CONTROL<br />

RUN<br />

CAP<br />

4<br />

3<br />

4 5 6 7 1 2<br />

8 9<br />

3<br />

2<br />

1<br />

Y<br />

L2 T2<br />

CONTACTOR<br />

FUSE<br />

(3A)<br />

W<br />

7<br />

DISCHARGE<br />

TEMP.<br />

SENSOR<br />

November 2007<br />

Page 39<br />

WATER<br />

LEVEL<br />

SENSOR<br />

BIN<br />

FULL<br />

RCV.<br />

BIN<br />

FULL<br />

X-MIT<br />

W/R<br />

SUMP<br />

TEMP.<br />

BK BK<br />

6<br />

5<br />

DISCHARGE<br />

TEMP.<br />

7 1<br />

8 2<br />

11 5<br />

12<br />

6<br />

LOAD LINE<br />

V<br />

4<br />

ELECTRONIC<br />

CONTROL<br />

5<br />

3<br />

TRANSFORMER<br />

2<br />

BK Y R<br />

1<br />

3<br />

4<br />

2<br />

BIN FULL<br />

TRANSMITTER<br />

1<br />

BN BN<br />

3<br />

3<br />

2<br />

PROTECTOR<br />

INTERNAL<br />

1<br />

TERMINAL BOX<br />

GROUND<br />

SCREW<br />

5<br />

2<br />

4<br />

BIN FULL<br />

RECIEVER<br />

CONTROL<br />

RELAY<br />

R<br />

G/Y<br />

3<br />

S2<br />

C1<br />

JUNCTION<br />

BOX<br />

Y<br />

2<br />

WATER<br />

PUMP<br />

CONTACTOR T1<br />

1<br />

BK<br />

COMMUNICATIONS<br />

PORT<br />

1<br />

HI PRESSURE<br />

CONTROL<br />

1<br />

2<br />

R3<br />

3<br />

POWER SUPPLY<br />

W<br />

COMPRESSOR<br />

EARTH GROUND<br />

WATER<br />

LEVEL<br />

SENSOR<br />

SEE NAMEPLATE FOR<br />

PROPER VOLTAGE REQUIREMENTS<br />

AND MAXIMUM FUSE SIZE<br />

START<br />

CAP.<br />

POTENTIAL<br />

RELAY<br />

POTENTIAL<br />

RELAY COIL<br />

CAUTION:<br />

RUN<br />

CAP.<br />

MORE THAN ONE DISCONNECT MEANS MAY BE<br />

REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />

COMPRESSOR<br />

THIS UNIT MUST<br />

BE GROUNDED.


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

B or C Series, 50 Hz Air Cooled CME506 Diagram<br />

November 2007<br />

Page 40


<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />

D thru H Series, 50 Hz <strong>CME256</strong> Diagram<br />

November 2007<br />

Page 41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!