CME256 Ice Machine - Parts Town
CME256 Ice Machine - Parts Town
CME256 Ice Machine - Parts Town
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
This parts list contains service part information for 8<br />
basic models, plus 4 different electrical configurations.<br />
The complete model number will be needed to<br />
identify the correct part.<br />
Model Series Changes (code at end of model number)<br />
• C series - changes to the front & side panels<br />
D series - changes to the top panel and to the<br />
compressor starting components<br />
E series - new side panels and 2 TXVs with<br />
check valves for the CME506<br />
F series - new water cooled condensers<br />
H series - color change<br />
Electrical Codes are located at the end of the model<br />
number (voltage/hertz/phase):<br />
-1 is 115/60/1<br />
-32 is 208-230/60/1<br />
-3 is 208-230/60/3<br />
-6 is 250/50/1<br />
November 2007<br />
Page 1<br />
Electrical Components Common to All <strong>Machine</strong>s:<br />
Inlet water valve<br />
Water sensor<br />
Discharge line sensor<br />
Controller<br />
<strong>Ice</strong> sensor/bin controls<br />
Water level sensor<br />
Unique Electrical Components<br />
Compressor and related starting components<br />
Contactor (single / three phase)<br />
Fan motor<br />
Water pump<br />
Transformer<br />
Hot gas valve<br />
Other Unique parts include: side panels, electrical,<br />
refrigeration and some water system items.<br />
TABLE OF CONTENTS<br />
Cabinet · · · · · · · · · · · · · · · · · · · ·<br />
Interior Structure & Controls · · · · · · · · ·<br />
<strong>CME256</strong> Air Cooled Refrigeration · · · · · ·<br />
PAGE 2<br />
PAGE 3<br />
PAGE 4<br />
A - C Series <strong>CME256</strong> and CME506 Air Cooled Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 24<br />
A - C Series Water Cooled Single Phase Schematic<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 25<br />
CME506 A-DSeries Air Cooled Refrigeration PAGE 5<br />
CME506 E-HSeries Air Cooled Refrigeration PAGE 6<br />
A - C Series <strong>CME256</strong> and CME506 Water Cooled Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 26<br />
CME656 Air Cooled Refrigeration · · · · · ·<br />
CME806 Air Cooled Refrigeration · · · · · ·<br />
Water System Components · · · · · · · · · ·<br />
PAGE 7<br />
PAGE 8<br />
PAGE 9<br />
A - C Series CME656 or CME806 Air Cooled Single<br />
Phase Wiring Diagram · · · · · · · · · · · · PAGE 27<br />
A - C Series CME656 Water Cooled Single Phase Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 28<br />
<strong>CME256</strong> Water Cooled Refrigeration · · · · · PAGE 10<br />
CME506 A-DSeries Water Cooled Refrigeration<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 11<br />
CME506 E-HSeries Water Cooled Refrigeration<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 12<br />
CME656 Water Cooled Refrigeration · · · · · PAGE 13<br />
CME806 Water Cooled Refrigeration · · · · · PAGE 14<br />
A - H Series Three Phase Air Cooled Schematic Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 29<br />
A - C Series CME656 Air Cooled Three Phase Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 30<br />
A - H Series CME656 Three Phase Water Cooled<br />
Schematic Diagram · · · · · · · · · · · · · · PAGE 31<br />
A - C Series CME656 Three Phase Water Cooled Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 32<br />
Compressors and Electrical Components for <strong>CME256</strong> and<br />
CME506 · · · · · · · · · · · · · · · · · · · · PAGE 15<br />
D thru H Series CME506 50 Hz Air Cooled Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 33<br />
Compressors and Electrical Components for CME656 and<br />
CME806 · · · · · · · · · · · · · · · · · · · · PAGE 16<br />
D thru H Series CME506 50 Hz Water Cooled Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 34<br />
HTB555 <strong>Ice</strong> Storage Bin · · · · · · · · · · · PAGE 17<br />
D thru H Series Single Phase 60 Hz Schematic Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 18<br />
D thru H Series, 115 volt <strong>CME256</strong> and CME506 Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 19<br />
D thru H Series CME656 or CME806 Single Phase Wiring<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 20<br />
D thru H Series CME656 Three Phase Wiring Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 21<br />
D thru H Series, 230 volt, 60 Hz. <strong>CME256</strong> and CME506<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 22<br />
A - C Series Single Phase Air Cooled Schematic Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 23<br />
D thru H Series CME656 or CME806 50 Hz Air Cooled<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 35<br />
D thru H Series CME656 or CME806 50 Hz Water Cooled<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 36<br />
B or C Series 50 Hz Water Cooled CME506 Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 37<br />
B or C Series, 50 Hz Air Cooled CME656 and CME806<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 38<br />
B or C Series, 50 Hz Water Cooled CME656 and CME806<br />
Diagram · · · · · · · · · · · · · · · · · · · · PAGE 39<br />
B or C Series, 50 Hz Air Cooled CME506 Diagram<br />
· · · · · · · · · · · · · · · · · · · · · · · · · PAGE 40<br />
D thru H Series, 50 Hz <strong>CME256</strong> Diagram · · PAGE 41
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
8<br />
9<br />
11<br />
7 6<br />
November 2007<br />
Page 2<br />
2 1<br />
Item Part<br />
Number Number Description<br />
1 A35963-021 Right side panel, grey w/ louvers<br />
A35963-022 Right side panel, stainless steel w/ louvers - fits all Air Cooled<br />
A37071-021 Right side panel, painted w/out louvers (water cooled only)<br />
A37071-022 A - D series right side panel, stainless steel without louvers (water cooled only)<br />
A38126-021 E - H series right side panel, w/out louvers for water cooled only<br />
2 02-3659-01 Top insulation<br />
3 02-3797-21 C series Front panel kit, gray plastic, includes trim strip & emblems<br />
03-1733-01 Strike (for C to H series panel, SS or plastic)<br />
A37167-001 Front panel kit, SS, replaces gray plastic or SS, includes item 10a (for A series)<br />
A37488-031 C to H series Front panel kit, stainless steel, includes trim strip & emblems<br />
3a 15-0808-01 Emblem for ss panel (Scotsman); 03-0271-00 is the speed nut for emblem<br />
3b 15-0792-02 Emblem for C to H series front panel, (CM 3 )<br />
4 03-1735-01 Screw for trim strip (for C to H series)<br />
03-1404-12 Sheet metal screw for plastic front panel (for A series)<br />
03-1419-22 Sheet metal screw for ss front panel<br />
5 02-1875-03 Panel bumper/hole plug<br />
6 03-1531-01 Sheet metal screw<br />
7 A35962-021 Left side panel, grey enamel with louvers<br />
A35962-022 Left side panel, stainless steel with louvers<br />
A37070-021 Left side panel, grey enamel without louvers (water cooled only)<br />
A37070-022 A - D series left side panel, stainless steel without louvers (water cooled only)<br />
A38127-021 E - H series left side panel, w/out louvers for water cooled only<br />
8 02-3485-01 Air filter, air cooled only<br />
9 A35965-001 Top panel, grey enamel, order item 2 also<br />
A35965-002 Top panel, stainless steel, order item 2 also<br />
02-3822-21 Top panel, plastic, fits all, original to H series<br />
10a 02-3663-01 Evaporator cover, use began Feb. 1997. Fits A and B series<br />
02-3796-01 Insulation for above cover<br />
02-3663-20 Evap cover w/ ins for C-Hseries<br />
11 03-1423-06 Speed nut for panel screws<br />
12 03-1733-02 Catch<br />
5<br />
Cabinet<br />
13<br />
4<br />
13 A37326-001 Filter bracket<br />
14 02-3794-31 Trim strip.<br />
03-1731-02 is the push nut for trim strip<br />
12<br />
10<br />
3<br />
3b<br />
3a<br />
4<br />
14
9<br />
26<br />
19<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
20<br />
21<br />
18<br />
8 7<br />
Item Part<br />
6<br />
Number Number Description<br />
1 11-0540-21 Bin Control Sensor (set)<br />
2 02-3337-01 Cube deflector<br />
3 02-3339-01 Stand pipe<br />
02-3610-01 Stand pipe adjusting nut<br />
4 02-3360-01 Reservoir washer<br />
5 13-0617-56 O-ring<br />
6 02-3338-01 Drain tube & fittings<br />
7 03-1404-18 Screw<br />
8 A36298-001 Left side channel<br />
9 03-1531-01 Screw<br />
10 A36297-001 Right side channel<br />
11 13-0906-01 Plastic inlet water hose,<br />
21" req. order 2 units - not used after Sept. 1996<br />
12 03-1645-01 Screw<br />
13 03-1691-01 Nylon screw<br />
14 02-3340-01 Reservoir cover<br />
15 12-2548-01 Inlet water valve<br />
16 13-0674-02<br />
unit<br />
Tubing, 9" req., order 1<br />
17 02-3443-01 Water fitting for hose<br />
16-1020-01 Water fitting for copper<br />
18 02-0179-05 Clamp<br />
19 13-0903-01 Bumper for side panels<br />
Interior Structure & Controls<br />
22<br />
7<br />
23<br />
10<br />
Note: Item 25 mounts to Item 1.<br />
Item 1 must have rectangular<br />
mounting tabs. All units after 9/96<br />
were mfg. with rectangular tabs.<br />
11 12<br />
18<br />
24<br />
17<br />
9<br />
November 2007<br />
Page 3<br />
27<br />
16<br />
7<br />
15<br />
5<br />
13<br />
14<br />
4<br />
20 16-0997-01 Inlet water fitting for hose<br />
16-1019-01 Inlet water fitting for copper<br />
21 16-0701-07 Mounting flange<br />
22 12-2838-23 AutoIQ controller<br />
23 12-2644-21 Low voltage harness A-Cseries<br />
12-2782-21 Low volt harness, D + series 60 Hz<br />
12-2782-23 Low volt harness, D + series 50 Hz<br />
24 12-2618-01 Hi volt harness, w fan control A series<br />
12-2476-01 Hi volt harness for w/o fan control A-C<br />
12-2678-01 Hi volt harness for 50 Hz models A-C<br />
12-2784-21 Hi volt harness for D + series 60 Hz.<br />
12-2786-21 Hi volt harness for D + series 50 Hz.<br />
25 02-3657-01 Cascading shield, used on<br />
CME806, 656 and 506 after 2/97<br />
26 A36460-001 Back panel assy (ac)<br />
A36460-003 Back panel assy (wc)<br />
27 A35959-001 Hi voltage box cover<br />
28 A36457-001 Foamed base<br />
1<br />
3<br />
25<br />
2<br />
28
12<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
<strong>CME256</strong> Air Cooled Refrigeration<br />
11<br />
8<br />
7<br />
See Page 15<br />
9<br />
Item Part<br />
Number Number Description<br />
10<br />
1 18-8745-01 Condenser<br />
2 03-1531-01 Screw<br />
For models with a fan control switch:<br />
3 A36031-001 Shroud<br />
The part number of the fan control pressure switch is: 11-0508-21<br />
4 A36668-001 Motor bracket<br />
5 18-8503-01 Fan blade<br />
6 18-5505-01 Fan motor for 115 volt, 60 Hz<br />
18-5505-12 Fan motor for 230 volt, 50 Hz<br />
18-5505-11 Fan motor for 230 volt, 60 Hz<br />
7 12-2471-01 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
8 16-1009-22 TXV<br />
02-4406-01 Insulation for TXV<br />
9 02-3319-01 Dryer<br />
10 A36734-020 Evaporator<br />
11 16-0832-21 Access valve<br />
11a 16-0832-03 Port cap<br />
11b 16-0832-02 Stem cap<br />
12 02-3410-21 Temp sensor, incl. water temp<br />
sensor & clip<br />
03-1711-01 Sensor clip<br />
13 16-1063-02 Hot gas valve strainer (not shown)<br />
November 2007<br />
Page 4<br />
4<br />
5<br />
6<br />
4<br />
2<br />
3<br />
1
11<br />
10<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
CME506 A-DSeries Air Cooled Refrigeration<br />
12 13<br />
Item Part<br />
See Page 15<br />
Number Number Description<br />
1 18-8744-01 Condenser<br />
2 03-1531-01 Screw<br />
3 A35967-001 Shroud<br />
4 A36668-001 Motor bracket<br />
5 18-8503-01 Fan blade<br />
6 18-5505-01 Fan motor for 115 volt, 60 Hz.<br />
18-5505-12 Fan motor for 230 volt, 50 Hz.<br />
18-5505-11 Fan motor for 230 volt, 60 Hz<br />
7 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
8 A36734-020 Evaporator<br />
9 16-1017-21 TXV (was 16-0867-21, they are interchangeable)<br />
02-4406-01 Insulation for TXV<br />
10 02-3410-21 Temp. sensor, includes water temp. & clip<br />
11 02-3319-02 Dryer<br />
12 16-0832-21 Access valve<br />
12a 16-0832-03 Port cap<br />
12b 16-0832-02 Stem cap<br />
7<br />
9<br />
15<br />
September 2009<br />
Page 5<br />
4<br />
5<br />
6<br />
4<br />
8<br />
For models with a fan control switch:<br />
The part number of the fan control pressure switch is: 11-0508-21<br />
13 16-0843-03 Distributor assembly<br />
14 16-1063-01 Hot gas valve strainer (not shown)<br />
15 03-1645-01 Screw<br />
2<br />
3<br />
1
8<br />
7<br />
12<br />
See Page 15<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
CME506 E-HSeries Air Cooled Refrigeration<br />
Item Part<br />
Number Number Description<br />
1 18-8866-02 Condenser - E Series & up<br />
2 03-1531-01 Screw<br />
3 A35967-001 Shroud<br />
4 A36668-001 Motor bracket<br />
5 18-8503-01 Fan blade<br />
6 18-5505-01 Fan motor for 115 volt, 60 Hz.<br />
18-5505-12 Fan motor for 230 volt, 50 Hz.<br />
18-5505-11 Fan motor for 230 volt, 60 Hz<br />
7 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
8 A36734-020 Evaporator<br />
9 16-1009-22 TXV - only for E series & up<br />
02-4405-01 Insulation for TXV<br />
10 02-3410-21 Temp. sensor, includes water<br />
temp. sensor. & clip<br />
14<br />
10<br />
9<br />
15<br />
9<br />
13<br />
16<br />
11<br />
August 2008<br />
Page 6<br />
4<br />
5<br />
6<br />
4<br />
Item Part<br />
Number Number Description<br />
11 02-3319-01 Dryer<br />
12 16-0832-21 Access valve<br />
12a 16-0832-03 Port cap<br />
12b 16-0832-02 Stem cap<br />
13 16-1071-01 Check valve<br />
14 16-1063-01 Hot gas valve strainer<br />
15 16-1095-01 Restrictor<br />
16 03-1645-01 Screw<br />
2<br />
3<br />
1
12<br />
11<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
13<br />
CME656 Air Cooled Refrigeration<br />
10<br />
7<br />
Item Part<br />
See Page 16<br />
9<br />
Number Number Description<br />
1 18-8739-01 Condenser<br />
2<br />
3<br />
4<br />
03-1531-01<br />
A35967-001<br />
A36668-001<br />
Screw<br />
Shroud<br />
Motor bracket<br />
8<br />
For models with a fan control switch:<br />
The part number of the fan control pressure switch is: 11-0508-21<br />
5 18-8503-01 Fan blade<br />
6 18-5505-11 Fan motor for 60 Hz.<br />
18-5505-12 Fan motor for 50 Hz.<br />
7 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
8 A36734-020 Evaporator<br />
9 16-1076-21 TXV (interchangeable with all prior)<br />
02-4406-01 Insulation for TXV<br />
10 16-0843-02 Distributor and tubes<br />
11 02-3410-21 Temperature sensor, includes water temp sensor & clip<br />
03-1711-01 Clip<br />
12 02-3319-02 Dryer<br />
13 16-0832-21 Access valve<br />
13a 16-0832-03 Port cap<br />
15 03-1645-01 Screw<br />
13b 16-0832-02 Stem cap<br />
14 16-1063-01 Hot gas valve strainer (not shown)<br />
15<br />
November 2007<br />
Page 7<br />
4<br />
5<br />
6<br />
4<br />
2<br />
3<br />
1
12 14<br />
11<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
CME806 Air Cooled Refrigeration<br />
13<br />
7<br />
10<br />
Item Part<br />
See Page 16<br />
Number Number Description<br />
1<br />
2<br />
18-8739-01<br />
03-1531-01<br />
Condenser<br />
Screw<br />
8<br />
3 A35967-001 Shroud<br />
4 A36668-001 Motor bracket<br />
5 18-8503-01 Fan blade<br />
6 18-8829-01 Fan motor for 60 Hz.<br />
18-8829-02 Fan motor for 50 Hz.<br />
7 12-2471-24 Hot gas valve complete w/coil<br />
12-2719-23 Hot gas valve coil only<br />
12-2733-30 Hot gas valve repair kit (no body, no coil)<br />
8 A36734-020 Evaporator<br />
9 16-1076-21 TXV (interchangeable with prior valve)<br />
02-4406-01 Insulation for TXV<br />
10 16-0843-02 Distributor and tubes<br />
11 02-3410-21 Temperature sensor, includes water temp sensor & clip<br />
03-1711-01 Clip<br />
12 02-3319-02 Dryer<br />
13<br />
13a<br />
16-0832-21<br />
16-0832-03<br />
Access valve<br />
Port cap<br />
15 03-1645-01 Screw<br />
13b 16-0832-02 Stem cap<br />
14 16-1063-01 Hot gas valve strainer<br />
November 2007<br />
Page 8<br />
9<br />
15<br />
4<br />
5<br />
6<br />
4<br />
2<br />
3<br />
1
5<br />
4<br />
Single Evaporator<br />
Models<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
1<br />
3<br />
2<br />
Water System Components<br />
1<br />
3<br />
6<br />
Item Part<br />
Two Evaporator Models<br />
Number Number Description<br />
1 02-2527-01 Water distributor<br />
2 A30926-001 Distributor manifold<br />
3 13-0898-02 Tubing grommet<br />
4<br />
5<br />
02-3361-01<br />
02-3410-21<br />
Water discharge tube for single evaporator models<br />
Water temperature sensor includes disch. temp. sensor<br />
13<br />
6 no number Cable tie<br />
7 02-3405-01 Inlet Tee<br />
15<br />
8<br />
13-0840-01<br />
02-3336-01<br />
Rubber plug<br />
Water distributor tube for<br />
double evaporator models<br />
12<br />
9 02-3383-01<br />
02-3383-02<br />
Float stem, 1 evaporator model*<br />
Float stem, 2 evaporator model*<br />
10 11-0539-51 Float (water level) sensor<br />
11 02-3388-04 Front pump bracket for 12-2586 type pump<br />
12 02-3388-05 Rear pump bracket for 12-2586 type pump<br />
13 12-2506-01 Harness<br />
14 02-3341-01 Float<br />
15 12-2586-21 <strong>CME256</strong>-1 (115 volt) pump<br />
12-2586-27 CME506-1 (115 volt) pump<br />
12-2586-26 <strong>CME256</strong>-6 or -32 (208-230 volt),<br />
12-2586-23 CME506-6 or 32 (208-230 volt),<br />
CME656 or CME806 (208-230 volt) pump. 50 or 60 Hz.<br />
* Not adjustable after 2/97. Then 1 evap model white, 2 evap. model grey.<br />
August 2008<br />
Page 9<br />
5<br />
6<br />
8<br />
3<br />
7<br />
1<br />
11<br />
1<br />
7<br />
9<br />
10<br />
14
8<br />
9<br />
10<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
<strong>CME256</strong> Water Cooled Refrigeration<br />
11<br />
See Page 15<br />
Item Part<br />
Number Number Description<br />
1 03-1403-15 Screw<br />
2 11-0478-01 Water regulating valve<br />
3 A36440-001 Back cover<br />
4 03-1645-01 Screw<br />
5 18-3306-25 Condenser, A thru E series<br />
18-8871-21 Condenser, F series<br />
6 02-3319-01 Dryer<br />
7 A36734-020 Evaporator<br />
8 02-3410-21 Hi temperature sensor,<br />
includes water temp sensor & clip<br />
03-1711-01 Clip for sensor<br />
9 11-0501-21 Hi pressure cut out<br />
10 16-0832-21 Access valve<br />
10a 16-0832-03 Port cap<br />
10b 16-0832-02 Stem cap<br />
11 16-1009-22 TXV 1/4 ton<br />
02-4406-01 Insulation for TXV<br />
12<br />
6<br />
November 2007<br />
Page 10<br />
3<br />
5<br />
4<br />
7<br />
14<br />
Item Part<br />
Number Number Description<br />
12 12-2471-01 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
13 16-1063-02 Hot gas valve strainer<br />
(not shown)<br />
14 A31828-001 Fitting<br />
1<br />
2
10<br />
11<br />
12<br />
See Page 15<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
9<br />
CME506 A-DSeries Water Cooled Refrigeration<br />
8<br />
Item Part<br />
Number Number Description<br />
7<br />
1 03-1403-15 Screw<br />
2 11-0478-01 Water regulating valve<br />
3 A36440-001 Back cover<br />
4 03-1645-01 Screw<br />
5 18-3306-25 Condenser<br />
6 02-3319-02 Dryer<br />
7 A36734-020 Evaporator<br />
8 16-1017-21 TXV 1/2 ton (was 16-0867-21) For A-DSeries only<br />
02-4406-01 Insulation for TXV<br />
9 16-0843-03 Distributor and tubes<br />
10 02-3410-21 Hi temperature sensor, includes water temperature sensor<br />
03-1711-01 Clip for sensor<br />
11 11-0501-21 Hi pressure cut out<br />
12 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
13 16-0832-21 Access valve<br />
13a 16-0832-03 Port cap<br />
14 16-1063-01 Hot gas valve strainer, not shown<br />
15 A31828-001 Fitting<br />
6<br />
November 2007<br />
Page 11<br />
5<br />
3<br />
4<br />
15<br />
1<br />
2
7<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
CME506 E-HSeries Water Cooled Refrigeration<br />
See Page 15<br />
4<br />
Item Part<br />
Number Number Description<br />
1 16-1063-01 Hot gas valve strainer<br />
2 11-0478-01 Water regulating valve<br />
3 16-1071-01 Check valve<br />
4 16-0832-21 Access valve<br />
16-0832-03 Port cap<br />
5 18-3306-25 Condenser, E series<br />
18-8871-21 Condenser, F&Hseries<br />
03-1645-01 Screw to mount condenser (not shown)<br />
6 02-3319-01 Dryer<br />
7 A36734-020 Evaporator<br />
8 16-1009-22 TXV for E Series & up<br />
02-4405-01 Insulation for TXV<br />
9 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
10 02-3410-21 Hi temperature sensor, includes water temperature sensor<br />
03-1711-01 Clip for sensor<br />
11 11-0501-21 Hi pressure cut out<br />
12 A31828-001 Fitting<br />
13 16-1095-01 Restrictor<br />
August 2008<br />
Page 12<br />
1<br />
10<br />
11<br />
8<br />
9<br />
13<br />
3<br />
5<br />
2<br />
6
10<br />
11<br />
12<br />
13<br />
See Page 16<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
9<br />
Item Part<br />
Number Number Description<br />
1 03-1403-15 Screw<br />
2 11-0478-01 Water regulating valve<br />
3 A36440-001 Back cover<br />
4 03-1645-01 Screw<br />
5 18-6900-25 Condenser, A-Eseries<br />
18-8874-21 Condenser, F series<br />
6 02-3319-02 Dryer<br />
7 A36734-020 Evaporator<br />
8 16-1076-21 TXV ( interchangeable<br />
w/prior valve)<br />
02-4406-01 Insulation for TXV<br />
9 16-0843-02 Distributor and tubes<br />
10 02-3410-21 Hi temperature sensor,<br />
includes water temperature sensor<br />
03-1711-01 Clip for sensor mounting<br />
CME656 Water Cooled Refrigeration<br />
8<br />
6<br />
14<br />
November 2007<br />
Page 13<br />
5<br />
7<br />
3<br />
4<br />
16<br />
Item Part<br />
Number Number Description<br />
11 11-0501-21 Hi pressure cut out<br />
12 12-2471-22 Hot gas valve w/coil<br />
12-2719-23 Hot gas valve coil only<br />
13 16-0832-21 Access valve<br />
13a 16-0832-03 Port cap<br />
14 16-0874-01 Receiver<br />
15 16-1063-01 Hot gas valve strainer,<br />
not shown<br />
16 A31828-001 Fitting<br />
1<br />
2
10<br />
11<br />
12<br />
13<br />
9<br />
See Page 16<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
Item Part<br />
Number Number Description<br />
1 03-1403-15 Screw<br />
2 11-0478-01 Water regulating valve<br />
3 A36440-001 Back cover<br />
4 03-1645-01 Screw<br />
5 18-6900-21 Condenser, A-Eseries<br />
18-8874-21 Condenser, F&Hseries<br />
6 02-3319-02 Dryer<br />
7 A36734-020 Evaporator<br />
8 16-1076-21 TXV (interchangeable with<br />
prior valve)<br />
8a 02-4406-01 Insulation for TXV<br />
9 16-0843-02 Distributor and tubes<br />
10 02-3410-21 Hi temperature sensor,<br />
includes water temperature sensor<br />
03-1711-01 Clip for sensor mounting<br />
11 11-0501-21 Hi pressure cut out<br />
CME806 Water Cooled Refrigeration<br />
8<br />
6<br />
November 2007<br />
Page 14<br />
7<br />
5<br />
3<br />
4<br />
15<br />
Item Part<br />
Number Number Description<br />
12 12-2471-24 Hot gas valve complete<br />
w/coil<br />
12-2719-23 Hot gas valve coil only<br />
12-2733-30 Hot gas valve repair kit, no<br />
coil, no body<br />
13 16-0832-21 Access valve<br />
13a 16-0832-03 Port cap<br />
14 16-1063-01 Hot gas valve strainer, not<br />
shown<br />
15 A31828-001 Fitting<br />
1<br />
2
Grommet,<br />
Sleeve<br />
-6B, C, D, E, F<br />
series<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
Compressors and Electrical Components for <strong>CME256</strong> and CME506<br />
Model <strong>CME256</strong> CME506<br />
Voltage/Hz 115/60 208-230/60 230/50 115/60 208-230/60 230/50<br />
Phase Single Single Single Single Single Single<br />
Compressor 18-8720-21* 18-8838-23* 18-8838-22 18-8721-21* 18-8839-23* 18-8721-22<br />
PTCR - D thru F<br />
series only<br />
<strong>CME256</strong> or<br />
CME506<br />
Transformer<br />
Compressor<br />
18-8835-01 18-8835-01 18-8835-01 18-8835-01 18-8835-01 18-8835-01<br />
Start Relay** 18-1903-44 not used not used 18-1903-50 not used 18-1903-29<br />
Start Capacitor** 18-1901-49 not used 18-2200-35 18-1901-03 not used 18-1901-43<br />
Run Capacitor 18-1902-52 18-1902-17 not used 18-1902-45 18-1902-45 18-1902-30<br />
Overload 18-5700-50 18-8838-50 18-5700-55 18-8711-50 18-8839-50 18-8721-50<br />
Mounting Bolt 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20<br />
Sleeve 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27<br />
Washer 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07<br />
Grommet 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28<br />
Contactor 12-2469-01 12-2469-01 12-2469-01 12-2469-01 12-2469-01 12-2469-01<br />
Transformer A37231-001 A37217-001 12-2639-02 A37231-001 A37217-001 A37217-001<br />
* Includes starting components. All compressors include a drier. ** D thru F series uses PTCR<br />
Bolt<br />
Hi Voltage<br />
Harness<br />
Transformer<br />
Washer<br />
Relay, A-C<br />
Series<br />
Fuse Fuse Block Relay Relay Bracket<br />
12-2639-02 12-2678-21 12-2686-01 12-2687-01 12-2679-01 12-2680-01<br />
November 2007<br />
Page 15<br />
Contactor<br />
Start Capacitor<br />
A - C Series Only<br />
Run Capacitor
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
Compressor<br />
Bolt<br />
Grommet,<br />
Sleeve Washer<br />
November 2007<br />
Page 16<br />
Contactor<br />
Model CME656 CME806<br />
Run Capacitor<br />
Voltage/Hz 208-230/60 208-230/60 230/50 208-230/60 208-230/60 230/50<br />
Phase Single Three Single Single Three Single<br />
Compressor 18-8813-23* 18-8813-25 18-8813-27 18-8749-22* 18-8749-24 18-8749-27<br />
PTCR - D thru<br />
F series only<br />
18-8835-01 not used 18-8835-01 18-8835-01 not used 18-8835-01<br />
Start Relay** 18-1903-33 not used 18-1903-29 18-1903-46 not used 18-1903-33<br />
Start<br />
Capacitor**<br />
18-1901-15 not used 18-1901-52 18-1901-48 not used 18-1901-48<br />
Run Capacitor 18-1902-53 not used 18-1902-53 18-1902-55 not used 18-1902-55<br />
Overload internal internal internal internal internal internal<br />
Mounting Bolt 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20 03-1405-20<br />
Sleeve 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27 18-2200-27<br />
Washer 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07 03-1407-07<br />
Grommet 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28 18-2200-28<br />
Contactor 12-2469-01 12-2533-01 12-2469-01 12-2469-01 12-2533-01 12-2469-01<br />
Transformer A37217-001 A37217-001 A37217-001 A37217-001 A37217-001 A37217-001<br />
* Includes starting components. All compressors include a drier. ** D thru F series uses PTCR<br />
-6B, C, D, E, F<br />
series<br />
CME656 or<br />
CME806<br />
Compressors and Electrical Components for CME656 and CME806<br />
Transformer<br />
Hi Voltage<br />
Harness<br />
Transformer<br />
Relay, A-C<br />
Series<br />
Start Capacitor<br />
A - C Series Only<br />
Fuse Fuse Block Relay Relay Bracket<br />
12-2639-02 12-2678-21 12-2686-01 12-2687-01 12-2679-01 12-2680-01
7<br />
8<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
Item Part<br />
Number Number Description<br />
1 02-2380-02 Spacer<br />
2 02-3196-01 Hinge<br />
3 02-2806-01 Shoulder screw<br />
4 03-1539-09 E-ring<br />
5 19-0503-04 Gasket 9 ft. *<br />
6 02-3274-02 Door frame (grey)<br />
7 13-0909-01 Door gasket - 58" *<br />
8 A36481-022 Door, grey, includes #7.<br />
9 03-0727-11 Thumb screw<br />
10 A35637-001 Canopy<br />
11 A35640-001 Baffle<br />
12 02-2809-02 Drain top<br />
13 13-0617-09 O-ring<br />
14 02-3108-01 Drain bottom<br />
Not shown<br />
03-1404-07 Screw for drain bottom<br />
05-0586-01 Drain elbow<br />
02-0540-00 Scoop<br />
KLP2E Enamel leg kit<br />
* Order gasket by the foot.<br />
Optional: A35477-001 Scoop holder, not shown<br />
9<br />
HTB555 <strong>Ice</strong> Storage Bin<br />
6<br />
11<br />
10<br />
December 2003<br />
Page 17<br />
Door<br />
Frame<br />
(ref)<br />
Bin Liner<br />
(ref) 12<br />
14<br />
4<br />
13<br />
5<br />
2<br />
1<br />
3
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series Single Phase 60 Hz Schematic Diagram<br />
L1<br />
DISCHARGE<br />
TEMP.<br />
TRANSFORMER<br />
LINE<br />
24V<br />
HI PRESSURE<br />
CONTROL<br />
(WCONLY)<br />
ELECTRONIC CONTROL<br />
SUMP<br />
TEMP.<br />
BI N<br />
FULL<br />
X- MIT<br />
BIN<br />
FULL<br />
RCV.<br />
CONTACTOR T1 WATER<br />
PUMP<br />
COMPRESSOR<br />
N(115/60/1UNITS)<br />
L2 (230/60/ 1 UNITS)<br />
HOT GAS VALVE<br />
WATER VALVE<br />
November 2007<br />
Page 18<br />
CONTACTOR<br />
COI L<br />
WATE R<br />
LEVEL<br />
SENSOR<br />
PTCR<br />
RUN<br />
CAP.<br />
FAN<br />
MOTOR<br />
(AC ONLY)
17-2747-01<br />
BIN FULL<br />
TRANSMITTER<br />
BIN FULL<br />
RECIEVER<br />
LB<br />
DI SCHARGE<br />
TEMP.<br />
SENSOR<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series, 115 volt <strong>CME256</strong> and CME506 Wiring Diagram<br />
SUMP TEMP.<br />
SENSOR<br />
WATER<br />
LEVEL<br />
SENSOR<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
WATER<br />
MOT<br />
(ACONLY) MOT<br />
HOT GAS<br />
PUMP<br />
FAN<br />
GRAY<br />
SOLENOID<br />
SOLENOID<br />
O<br />
5<br />
4<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
5<br />
4<br />
3<br />
2<br />
1<br />
2 1<br />
3<br />
1 2 3 4 5 6 7 1 2 3 4<br />
8 9<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
O<br />
ELECTRONIC CONTR OL<br />
COMMUNICATIONS<br />
PORT<br />
CAUTION:<br />
USE COPPER CONDUCTORS ONLY<br />
BU<br />
BN<br />
W<br />
BK<br />
BK<br />
Y<br />
V<br />
HI PRESSURE<br />
CONTROL<br />
(WC ONLY)<br />
MOR E TH AN O NE D I S CO NN EC T ME AN S MA Y BE<br />
REQUI RED TO DI SCONNECT ALL POWER TO THI S UNI T.<br />
O<br />
LOAD<br />
W<br />
LI NE<br />
TRANSFORMER<br />
BK<br />
BK<br />
November 2007<br />
Page 19<br />
O<br />
W<br />
JUNCTION<br />
BOX<br />
W<br />
GROUND<br />
SCREW<br />
POWER SUPPLY<br />
S EE NAMEPL ATE FOR<br />
P ROP ER VOL TAGE REQUI RE MENTS<br />
A ND MAX I MUM F USE SI ZE<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
L1<br />
L2<br />
Y<br />
T1<br />
T2<br />
CONTACTOR<br />
EARTH GROUND<br />
C AUT I ON : P TCR WI LL BE HOT .<br />
C OMP RE S S OR MA Y N OT S T A RT I F<br />
P TCR I S NOT A LLOWED TO COOL.<br />
W/ R<br />
RUNWINDING<br />
STARTWINDING<br />
FUSITE<br />
BK<br />
R<br />
W<br />
W/ Y<br />
S<br />
C<br />
R<br />
PTCR<br />
RUN<br />
CAP<br />
BK<br />
W/ R<br />
BK Y R<br />
EXTERNAL<br />
PROTECTOR<br />
COMPRESSOR
17-2751-01<br />
BIN FULL<br />
TRANSMITTER<br />
BIN FULL<br />
RECIEVER<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME656 or CME806 Single Phase Wiring Diagram<br />
LB<br />
DI SCHARGE<br />
TEMP.<br />
SENSOR<br />
WATER<br />
MOT<br />
(ACONLY) MOT<br />
HOT GAS<br />
PUMP<br />
FAN<br />
GRAY<br />
SOLENOID<br />
SOLENOID<br />
SUMP TEMP.<br />
SENSOR<br />
WATER<br />
LEVEL<br />
SENSOR<br />
O<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
5<br />
4<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
5<br />
4<br />
3<br />
2<br />
1<br />
2 1<br />
6<br />
3<br />
1 2 3 4 5 6 7 1 2 3 4<br />
8 9<br />
7<br />
5<br />
4<br />
3<br />
2<br />
1<br />
O<br />
BU<br />
ELECTRONIC CONTR OL<br />
COMMUNICATIONS<br />
PORT<br />
BN<br />
W<br />
BK<br />
BK<br />
Y<br />
CAUTION:<br />
V<br />
USE COPPER CONDUCTORS ONLY<br />
HI PRESSURE<br />
CONTROL<br />
(WC ONLY)<br />
LOAD<br />
W<br />
BK<br />
O<br />
November 2007<br />
Page 20<br />
W<br />
BK<br />
BK/ W<br />
POWER SUPPLY<br />
SEE NAMEPLATE FOR<br />
P ROP ER VOL TAGE REQUI RE MENTS<br />
A ND MAX I MUM F USE SI ZE<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
GROUND<br />
SCREW<br />
MOR E TH AN ONE D I S CONN EC T ME AN S MA Y BE<br />
REQUI RED TO DI SCONNECT AL L POWER TO THI S UNI T.<br />
O<br />
LI NE<br />
TRANSFORMER<br />
JUNCTION<br />
BOX<br />
L1<br />
L2<br />
T2<br />
CONTACTOR<br />
EARTH GROUND<br />
C AUT I ON : P TCR WI LL BE HOT .<br />
C OMP RE S S OR MA Y N OT S T A RT I F<br />
P T C R I S N O T A L L O W E D T O C O O L .<br />
T1<br />
Y<br />
PROTECTOR<br />
INTERNAL<br />
COMPRESSOR<br />
TERMINAL BOX<br />
R<br />
BK<br />
W<br />
W/ Y<br />
W/ R<br />
PTCR<br />
RUN<br />
CAP<br />
C1 S2<br />
R3<br />
W/ R<br />
BK Y R
17-2757-01<br />
BIN FULL<br />
TRANSMITTER<br />
BIN FULL<br />
RECIEVER<br />
LB<br />
DI SCHARGE<br />
TEMP.<br />
SENSOR<br />
SUMP TEMP.<br />
SENSOR<br />
WATER<br />
LEVEL<br />
SENSOR<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME656 Three Phase Wiring Diagram<br />
O<br />
5<br />
4<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
5<br />
4<br />
3<br />
2<br />
1<br />
2 1<br />
3<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
USE COPPER CONDUCTORS ONLY<br />
WATER<br />
MOT<br />
(ACONLY) MOT<br />
HOT GAS<br />
PUMP<br />
FAN<br />
GRAY<br />
SOLENOID<br />
SOLENOID<br />
5<br />
4<br />
3<br />
2<br />
1<br />
O<br />
BU<br />
ELECTRONIC CONTR OL<br />
BN<br />
1 2 3 4 5 6 7 1 2 3 4<br />
8 9<br />
7<br />
6<br />
COMMUNICATIONS<br />
PORT<br />
CAUTION:<br />
W<br />
BK<br />
BK<br />
Y<br />
V<br />
HI PRESSURE<br />
CONTROL<br />
(WC ONL Y)<br />
W<br />
BK<br />
November 2007<br />
Page 21<br />
O<br />
W<br />
GROUND<br />
SCREW<br />
EARTH GROUND<br />
MOR E TH AN ONE D I S CONN EC T ME AN S MA Y BE<br />
REQUI RED TO DI SCONNECT ALL POWER TO THI S UNIT. LOAD<br />
O<br />
LI NE<br />
TRANSFORMER<br />
JUNCTION<br />
BOX<br />
BK<br />
BK<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
BK<br />
L1<br />
L2<br />
L3<br />
T1<br />
T2<br />
T3<br />
CONTACTOR<br />
POWER SUPPLY<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
Y<br />
PROTECTOR<br />
INTERNAL<br />
R<br />
BK<br />
W<br />
COMPRESSOR<br />
TERMINAL BOX<br />
R R R<br />
C1<br />
R3<br />
S2
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series, 230 volt, 60 Hz. <strong>CME256</strong> and CME506 Diagram<br />
November 2007<br />
Page 22
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series Single Phase Air Cooled Schematic Diagram<br />
November 2007<br />
Page 23
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series <strong>CME256</strong> and CME506 Air Cooled Wiring Diagram<br />
August 2006<br />
Page 24
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series Water Cooled Single Phase Schematic Diagram<br />
November 2007<br />
Page 25
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series <strong>CME256</strong> and CME506 Water Cooled Wiring Diagram<br />
November 2007<br />
Page 26
BIN FULL<br />
TRANSMITTER<br />
BIN FULL<br />
RECIEVER<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series CME656 or CME806 Air Cooled Single Phase Wiring Diagram<br />
A36659-001<br />
BU<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
SUMP TEMP.<br />
SENSOR<br />
WATER<br />
LEVEL<br />
SENSOR<br />
O<br />
1 2 3 4 5 6 7 1 2 3 4<br />
8 9<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
5<br />
4<br />
3<br />
2<br />
1<br />
3<br />
2<br />
1<br />
5<br />
4<br />
3<br />
2<br />
1<br />
O<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
USE COPPER CONDUCTORS ONLY<br />
WATER HOT GAS<br />
SOLENOID<br />
MOT<br />
PUMP<br />
O<br />
BU<br />
ELECTRONIC<br />
CONTROL<br />
COMMUNICATIONS<br />
PORT<br />
MOT<br />
FAN<br />
BN<br />
W/BU<br />
BK<br />
BK/W<br />
V<br />
R<br />
W/BN<br />
POTENTIAL RELAY<br />
LOAD<br />
5<br />
SOLENOID<br />
BU<br />
BK/W<br />
November 2007<br />
Page 27<br />
1<br />
2<br />
LINE<br />
TRANSFORMER<br />
O<br />
W<br />
JUNCTION<br />
BOX<br />
2<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
2 WIRE COLOR FOR 208-230/60/1 UNITS: BLACK<br />
WIRE COLOR FOR 230/50/1 UNITS : BROWN<br />
2<br />
GROUND<br />
SCREW<br />
L1<br />
L2<br />
W/R<br />
BN<br />
Y/W<br />
EARTH GROUND<br />
POWER SUPPLY<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
Y<br />
PROTECTOR<br />
INTERNAL<br />
START<br />
CAP<br />
RUN<br />
CAP<br />
R/W<br />
BK Y R<br />
CAUTION:<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />
T1<br />
T2<br />
CONTACTOR<br />
R<br />
BK<br />
W<br />
COMPRESSOR<br />
TERMINAL BOX<br />
C1<br />
R3<br />
S2
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series CME656 Water Cooled Single Phase Wiring Diagram<br />
November 2007<br />
Page 28
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - H Series Three Phase Air Cooled Schematic Diagram<br />
November 2007<br />
Page 29
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series CME656 Air Cooled Three Phase Wiring Diagram<br />
November 2007<br />
Page 30
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - H Series CME656 Three Phase Water Cooled Schematic Diagram<br />
November 2007<br />
Page 31
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
A - C Series CME656 Three Phase Water Cooled Wiring Diagram<br />
November 2007<br />
Page 32
USE COPPER CONDUCTORS ONLY<br />
17-2749-01<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
O<br />
WATER HOT GAS<br />
MOT<br />
MOT<br />
PUMP FAN<br />
GRAY<br />
SOLENOID<br />
SOLENOID<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME506 50 Hz Air Cooled Diagram<br />
BN<br />
BN<br />
CAUTION: PTCR WILL BE HOT.<br />
BU/BN<br />
COMPRESSOR MAY NOT START IF<br />
BU<br />
BU/W<br />
L2<br />
TRANSFORMER<br />
L1<br />
PTCR IS NOT ALLOWED TO COOL.<br />
0<br />
O<br />
LB<br />
BU<br />
LI NE<br />
6 4<br />
6 4<br />
HOTGASVALVE<br />
24V<br />
0<br />
1 0<br />
1 0<br />
PTCR<br />
WATER VAL VE<br />
CONTROL RELAY 1 CONTROL RELAY 2<br />
FUSE<br />
O<br />
O<br />
CONTACTOR COIL<br />
V<br />
CONTROL REL AY 1 COIL<br />
Y<br />
CONTROL RELAY 2 COIL<br />
W/R<br />
W/Y<br />
W/BU<br />
T1<br />
L1<br />
V<br />
V<br />
BK<br />
W/BN<br />
SUMPTEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
L2 T2<br />
CONTACTOR<br />
FUSE<br />
(3A)<br />
4<br />
4 5 6 7 1 2 3<br />
8 9<br />
3<br />
2<br />
1<br />
W<br />
7<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
W/R<br />
November 2007<br />
Page 33<br />
WATER<br />
LEVEL<br />
SENSOR<br />
BIN<br />
BI N<br />
FULL<br />
X- MI T<br />
6<br />
FULL<br />
SUMP<br />
TEMP.<br />
5<br />
RCV.<br />
DISCHARGE<br />
TEMP.<br />
7 1<br />
8 2<br />
BK<br />
BK<br />
11 5<br />
12 6<br />
TRANSFORMER<br />
V<br />
4<br />
LOADLINE<br />
3<br />
2<br />
5<br />
BK Y R<br />
ELECTRONIC<br />
CONTROL<br />
1<br />
3<br />
2<br />
4<br />
BIN FULL<br />
TRANSMITTER<br />
1<br />
BU BN<br />
3<br />
2<br />
3<br />
CONTROL RELAY 2<br />
1<br />
GROUND<br />
SCREW<br />
5<br />
CONTROL RELAY 1<br />
4<br />
3<br />
2<br />
BIN FULL<br />
RECIEVER<br />
G/Y<br />
JUNCTION<br />
BOX<br />
2<br />
FAN<br />
MOTOR<br />
CONTACTOR T1 WATER<br />
PUMP<br />
FUSITE<br />
1<br />
1<br />
BK<br />
R<br />
COMMUNICATIONS<br />
PORT<br />
2<br />
1<br />
3<br />
C<br />
RUN<br />
EXTERNAL<br />
PROTECTOR<br />
COMPRESSOR<br />
BK<br />
WINDING<br />
POWER SUPPLY<br />
S<br />
R<br />
WATER<br />
LEVEL<br />
SENSOR<br />
START<br />
W<br />
WINDING<br />
EARTH GROUND<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SI ZE<br />
CAUTION:<br />
PTCR<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
REQUIRE D TO DISCONNECT ALL POWER TO THI S UNIT.<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
RUN<br />
CAP.<br />
COMPRESSOR
USE COPPER CONDUCTORS ONLY<br />
17-2750-01<br />
1 DA SHED LI NES INDICATEFI EL D WI RINGWHI CH MUST BE<br />
INSTALLEDIN ACCORDANCE WI THTHE NATI ONAL EL ECTRI CAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
O<br />
WATER HOT GAS<br />
MOT<br />
PUMP<br />
GRAY<br />
SOLENOI D<br />
SOLENOI D<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME506 50 Hz Water Cooled Diagram<br />
BN<br />
BU/BN<br />
BN<br />
BU/ W<br />
CAUTION: PTCR WILL BE HOT.<br />
OO<br />
COMPRESSOR MAY NOT START IF<br />
L2<br />
TRANSFORMER<br />
L1<br />
PTCR IS NOT ALLOWED TO COOL.<br />
LB<br />
LINE<br />
FOR USE ONLY<br />
ON AIR UNITS<br />
24V<br />
HOT GAS VALVE<br />
6 4<br />
PTCR<br />
WATER VALVE<br />
FUSE<br />
O<br />
1 0<br />
O<br />
CONTACTOR<br />
COIL<br />
V<br />
HI-PRESS<br />
CONTROL<br />
BU<br />
W/BU CONTROL<br />
RELAY<br />
O<br />
CONTROL RELAY COIL<br />
W/R<br />
W/Y<br />
W/BN<br />
T1<br />
L1<br />
V<br />
V<br />
BK<br />
SUMP TEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
L2 T2<br />
CONTACTOR<br />
FUSE<br />
(3A)<br />
4<br />
4 5 6 7 1 2 3<br />
8 9<br />
3<br />
2<br />
1<br />
Y<br />
W<br />
7<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
W/R<br />
November 2007<br />
Page 34<br />
WATER<br />
LEVEL<br />
SENSOR<br />
BIN<br />
FULL<br />
RCV.<br />
BIN<br />
FULL<br />
X-MIT<br />
SUMP<br />
TEMP.<br />
6<br />
5<br />
DISCHARGE<br />
TEMP.<br />
7 1<br />
8 2<br />
BK<br />
11 5<br />
12 6<br />
LOADLINE<br />
BK<br />
V<br />
ELECTRONIC<br />
CONTROL<br />
4<br />
5<br />
3<br />
2<br />
TRANSFORMER<br />
1<br />
BK Y R<br />
3<br />
4<br />
2<br />
BIN FULL<br />
TRANSMITTER<br />
1<br />
BU BN BN<br />
3<br />
3<br />
2<br />
1<br />
GROUND<br />
SCREW<br />
5<br />
2<br />
4<br />
BIN FULL<br />
RECIEVER<br />
CONTROL<br />
RELAY<br />
CONTACTOR T1 WATER<br />
PUMP<br />
JUNCTION<br />
BOX<br />
3<br />
G/Y<br />
Y<br />
2<br />
FUSITE<br />
1<br />
1<br />
BK<br />
R<br />
COMMUNICATIONS<br />
PORT<br />
C<br />
RUNWINDING<br />
3 2 1<br />
POWER SUPPLY<br />
HI PRESSURE<br />
CONTROL<br />
EXTERNAL<br />
PROTECTOR<br />
COMPRESSOR<br />
S<br />
BK<br />
R<br />
W<br />
STARTWINDING<br />
EARTH GROUND<br />
WATER<br />
LEVEL<br />
SENSOR<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
PTCR<br />
CAUTION:<br />
THIS UNIT MUST<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
BE GROUNDED.<br />
RUN<br />
CAP.<br />
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />
COMPRESSOR
USE COPPER CONDUCTORS ONLY<br />
17-2753-01<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME656 or CME806 50 Hz Air Cooled Diagram<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
O<br />
WATER HOT GAS<br />
MOT<br />
MOT<br />
PUMP<br />
FAN<br />
GRAY<br />
SOLENOID<br />
SOLENOID<br />
BN<br />
C A U T I O N : P T C R W I L L BE H O T .<br />
BU/ BN<br />
BN<br />
BU/ W<br />
C O M P R E S S O R M A Y N O T STA R T I F<br />
P T C R I S N O T A L L O W E D T O C O O L .<br />
L2<br />
BU<br />
TRANSFORMER<br />
L1<br />
O<br />
O<br />
BU<br />
BU<br />
LINE<br />
6 4<br />
6 4<br />
24V<br />
HOT GAS VALVE<br />
O<br />
1 0<br />
1 0<br />
PTCR<br />
WAT ER VALVE<br />
CONT ROL RE LAY 1 CONT ROL RE LAY 2<br />
FUSE<br />
O<br />
CONTACTOR COI L<br />
V<br />
Y<br />
CONTROL REL AY 1 COI L<br />
O<br />
CONTROL REL AY 2 COI L<br />
W/ R<br />
W/ Y<br />
W/ BU<br />
T1<br />
L1<br />
V<br />
V<br />
BK<br />
W/ BN<br />
SUMPTEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
L2 T2<br />
CONTACTOR<br />
FUSE<br />
(3A)<br />
4<br />
4 5 6 7 1 2 3<br />
8 9<br />
3<br />
2<br />
1<br />
W<br />
7<br />
DI SCHARGE<br />
TEMP.<br />
SENSOR<br />
W/ R<br />
6<br />
November 2007<br />
Page 35<br />
WAT ER<br />
LEVEL<br />
SENSOR<br />
BI N<br />
FULL<br />
RCV.<br />
BI N<br />
FULL<br />
X- MI T<br />
SUMP<br />
TEMP.<br />
5<br />
DI SCHARGE<br />
TEMP.<br />
7 1<br />
8 2<br />
BK<br />
11 5<br />
12 6<br />
LOADLINE<br />
BK<br />
V<br />
4<br />
5<br />
3<br />
2<br />
TRANSFORMER<br />
ELECTRONI C<br />
CONTROL<br />
1<br />
BK Y R<br />
3<br />
1 2 4<br />
BIN FULL<br />
TRANSMITTER<br />
BU BN<br />
3<br />
2<br />
1 3<br />
CONTROL REL AY 2<br />
GROUND<br />
SCREW<br />
5<br />
CONTROL REL AY 1<br />
BIN FULL<br />
RECIEVER<br />
G/ Y<br />
JUNCTION<br />
BOX<br />
1 2 3 4 2<br />
FAN<br />
MOT OR<br />
CONTACTOR T1 WAT ER<br />
PUMP<br />
TERMINAL BOX<br />
PROTECTOR<br />
INTERNAL<br />
COMMUNICATIONS<br />
PORT<br />
1<br />
3 2 1<br />
R<br />
S2<br />
C1<br />
POWER SUPPLY<br />
BK<br />
EARTH GROUND<br />
WATER<br />
LEVEL<br />
SENSOR<br />
R3<br />
SEE NAMEPL ATE FOR<br />
PROPER VOL TAGE REQUI REMENTS<br />
AND MAXI MUM FUSE SI ZE<br />
PTCR<br />
W<br />
COMPRESSOR<br />
RUN<br />
CAP.<br />
CAUTION:<br />
MORE THAN ONE DI SCONNECT ME AN S MA Y BE<br />
REQUI RED TO DI SCONNECT AL L POWE R TO THI S UN I T .<br />
THIS UNIT MUST<br />
BE GROUNDED.<br />
COMPRESSOR
USE COPPER CONDUCTORS ONLY<br />
17-2754-01<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series CME656 or CME806 50 Hz Water Cooled Diagram<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
O<br />
WATER<br />
HOT GAS<br />
MOT<br />
PUMP<br />
GRAY<br />
SOLENOID SOLENOID<br />
C A U T I O N : P T C R W I L L B E H O T .<br />
C O M P R E S S O R M A Y N O T S T A R T I F<br />
BN<br />
BU/ BN<br />
P T C R I S N O T A L L O W E D T O C O O L .<br />
BN<br />
BU/ W<br />
OO<br />
L2<br />
TRANSFORMER<br />
L1<br />
FOR USE ONLY<br />
ON AI R UNI TS<br />
BU<br />
LINE<br />
24V<br />
HOT GAS VALVE<br />
4<br />
6<br />
PTCR<br />
WAT ER VALVE<br />
FUSE<br />
0<br />
1<br />
O<br />
O<br />
CONTACTOR<br />
COI L<br />
V<br />
HI - PRESS<br />
CONT ROL<br />
CONTROL<br />
REL AY<br />
W/ BU<br />
BU<br />
O<br />
CONTROL REL AY COI L<br />
W/ R<br />
W/ Y<br />
W/ BN<br />
L1 T1<br />
V<br />
V<br />
BK<br />
SUMPTEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
L2 T2<br />
FUSE<br />
(3A)<br />
Y<br />
CONTACTOR<br />
W<br />
1 2 3 45 6 7 12 3 4<br />
8<br />
9<br />
7<br />
November 2007<br />
Page 36<br />
BK<br />
LOADLINE 6<br />
7 1<br />
8 2<br />
11 5<br />
12<br />
TRANSFORMER<br />
DI SCHARGE<br />
TEMP.<br />
SENSOR<br />
WAT ER<br />
LEVEL<br />
SENSOR<br />
BI N<br />
FULL<br />
RCV.<br />
BI N<br />
FULL<br />
X- MI T<br />
W/ R<br />
BK<br />
6<br />
SUMP<br />
TEMP.<br />
DI SCHARGE<br />
TEMP.<br />
V<br />
ELECTRONI C<br />
CONTROL<br />
5<br />
1 23 4 5<br />
Y R<br />
BK<br />
4<br />
1 2 3<br />
BIN FULL<br />
TRANSMITTER<br />
BN BN<br />
BU<br />
3<br />
1 2 3<br />
TERMINAL BOX<br />
PROTECTOR<br />
INTERNAL<br />
GROUND<br />
SCREW<br />
2<br />
CONTROL<br />
REL AY<br />
G/ Y<br />
JUNCTION<br />
BOX<br />
Y<br />
1 2 34 5<br />
BIN FULL<br />
RECIEVER<br />
R<br />
S2<br />
C1<br />
WAT ER<br />
PUMP<br />
CONTACTOR T1<br />
BK<br />
COMMUNICATIONS<br />
PORT<br />
1<br />
3 21<br />
R3<br />
POWER SUPPLY<br />
HI PRESSURE<br />
CONTROL<br />
W<br />
COMPRESSOR<br />
EARTH GROUND<br />
WATER<br />
LEVEL<br />
SENSOR<br />
SEE NAMEPL ATE FOR<br />
PROPER VOL TAGE REQUI REMENTS<br />
AND MAXI MUM FUSE SI ZE<br />
PTCR<br />
CAUTION:<br />
MORE THAN ONE DI SCONNECT ME AN S MA Y BE<br />
THIS UNIT MUST<br />
RUN<br />
CAP.<br />
REQUI RED TO DI SCONNECT AL L POWE R TO THI S UN I T .<br />
BE GROUNDED.<br />
COMPRESSOR
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
USE COPPER CONDUCTORS ONLY<br />
17-2484-01<br />
WATER HOT GAS<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
B or C Series 50 Hz Water Cooled CME506 Diagram<br />
O<br />
R<br />
MOT<br />
PUMP<br />
SOLENOID<br />
SOLENOID<br />
W/BN<br />
BN<br />
W/BU<br />
BU/W<br />
O<br />
L2<br />
TRANSFORMER<br />
L1<br />
O<br />
BU<br />
LINE<br />
CONTROL BOX<br />
POTENTIAL RELAY<br />
HOT GAS VALVE<br />
24V<br />
BN<br />
1<br />
5<br />
2 4<br />
WATER VALVE<br />
START<br />
CAP<br />
FUSE<br />
Y/W<br />
2<br />
1 0<br />
O<br />
CONTACTOR<br />
COIL<br />
HI-PRESS<br />
CONTROL<br />
BU<br />
BU CONTROL<br />
V<br />
BK<br />
RELAY<br />
O<br />
CONTROL RELAY COIL<br />
R/W<br />
T1<br />
L1<br />
BK/W<br />
BK<br />
BK/W<br />
SUMP TEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
4<br />
3<br />
4 5 6 7 1 2<br />
8 9<br />
3<br />
2<br />
1<br />
Y<br />
L2 T2<br />
CONTACTOR<br />
FUSE<br />
(3A)<br />
W<br />
7<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
November 2007<br />
Page 37<br />
1<br />
WATER<br />
LEVEL<br />
SENSOR<br />
BIN<br />
FULL<br />
RCV.<br />
BIN<br />
FULL<br />
X-MIT<br />
W/R<br />
7<br />
8<br />
SUMP<br />
TEMP.<br />
BK BK<br />
2<br />
6<br />
5<br />
DISCHARGE<br />
TEMP.<br />
ELECTRONIC<br />
CONTROL<br />
4<br />
6<br />
11 5<br />
12<br />
LOAD LINE<br />
V<br />
5<br />
3<br />
TRANSFORMER<br />
2<br />
BK Y R<br />
1<br />
3<br />
4<br />
2<br />
BIN FULL<br />
TRANSMITTER<br />
1<br />
BN BN<br />
3<br />
3<br />
2<br />
1<br />
GROUND<br />
SCREW<br />
5<br />
2<br />
4<br />
BIN FULL<br />
RECIEVER<br />
CONTROL<br />
RELAY<br />
G/Y<br />
JUNCTION<br />
BOX<br />
3<br />
Y<br />
2<br />
WATER<br />
PUMP<br />
CONTACTOR T1<br />
FUSITE<br />
1<br />
1<br />
1<br />
BK<br />
R<br />
COMMUNICATIONS<br />
PORT<br />
2<br />
C<br />
RUN WINDING<br />
HI PRESSURE<br />
CONTROL<br />
3<br />
POWER SUPPLY<br />
EXTERNAL<br />
PROTECTOR<br />
COMPRESSOR<br />
S<br />
BK<br />
R<br />
WATER<br />
LEVEL<br />
SENSOR<br />
W<br />
START WINDING<br />
EARTH GROUND<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
START<br />
CAP.<br />
POTENTIAL<br />
RELAY<br />
POTENTIAL<br />
RELAY COIL<br />
CAUTION:<br />
RUN<br />
CAP.<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />
COMPRESSOR<br />
THIS UNIT MUST<br />
BE GROUNDED.
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
B or C Series, 50 Hz Air Cooled CME656 and CME806 Diagram<br />
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
USE COPPER CONDUCTORS ONLY<br />
17-2485-01<br />
HOT GAS<br />
MOT<br />
PUMP<br />
WATER<br />
O<br />
R<br />
MOT<br />
FAN<br />
SOLENOID SOLENOID<br />
W/BN<br />
BN/W<br />
W/BU<br />
BU/W<br />
O<br />
L1 TRANSFORMER<br />
L2<br />
LINE<br />
0<br />
0<br />
BK<br />
O<br />
BU<br />
BK<br />
CONTROL BOX<br />
6 4<br />
HOT GAS VALVE<br />
24V<br />
POTENTIAL RELAY<br />
5 1<br />
6 4<br />
1 0<br />
BN<br />
0<br />
1<br />
WATER VALVE<br />
START<br />
CAP<br />
Y/W<br />
CONTROL RELAY 2<br />
CONTROL RELAY 1<br />
BU<br />
FUSE<br />
2<br />
O<br />
CONTACTOR COIL<br />
BU<br />
V<br />
CONTROL RELAY 1 COIL<br />
CONTROL RELAY 2 COIL<br />
R/W<br />
L1 T1<br />
BK/W<br />
BK<br />
BN<br />
BK/W<br />
SUMP TEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
FUSE<br />
(3A)<br />
L2 T2<br />
CONTACTOR<br />
1 2 3 4 5 6 7 1 2 3 4<br />
8<br />
9<br />
November 2007<br />
Page 38<br />
Y<br />
W<br />
7<br />
1<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
WATER<br />
LEVEL<br />
SENSOR<br />
BIN<br />
FULL<br />
RCV.<br />
BIN<br />
FULL<br />
X-MIT<br />
W/R<br />
7<br />
8<br />
SUMP<br />
TEMP.<br />
BK BK<br />
2<br />
6<br />
DISCHARGE<br />
TEMP.<br />
6<br />
11 5<br />
12<br />
LOAD LINE<br />
V<br />
5<br />
TRANSFORMER<br />
1 2 3 4 5<br />
Y R<br />
BK<br />
ELECTRONIC<br />
CONTROL<br />
4<br />
1 2 3<br />
BIN FULL<br />
TRANSMITTER<br />
BN BN<br />
3<br />
1 2 3<br />
CONTROL RELAY 2<br />
TERMINAL BOX<br />
PROTECTOR<br />
INTERNAL<br />
GROUND<br />
SCREW<br />
CONTROL RELAY 1<br />
2<br />
R<br />
C1 S2<br />
1 2 3 4 5<br />
BIN FULL<br />
RECIEVER<br />
G/Y<br />
JUNCTION<br />
BOX<br />
FAN<br />
MOTOR<br />
WATER<br />
PUMP<br />
CONTACTOR T1<br />
BK<br />
COMMUNICATIONS<br />
PORT<br />
1<br />
1 2 3<br />
R3<br />
POWER SUPPLY<br />
WATER<br />
LEVEL<br />
SENSOR<br />
COMPRESSOR<br />
W<br />
EARTH GROUND<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
START<br />
CAP.<br />
POTENTIAL<br />
RELAY<br />
POTENTIAL<br />
RELAY COIL<br />
CAUTION:<br />
RUN<br />
CAP.<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />
COMPRESSOR<br />
THIS UNIT MUST<br />
BE GROUNDED.
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE<br />
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL<br />
CODE AND ALL STATE AND LOCAL CODES.<br />
USE COPPER CONDUCTORS ONLY<br />
17-2593-01<br />
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
B or C Series, 50 Hz Water Cooled CME656 and CME806 Diagram<br />
WATER HOT GAS<br />
O<br />
R<br />
MOT<br />
PUMP<br />
SOLENOID<br />
SOLENOID<br />
W/BN<br />
BN/W<br />
W/BU<br />
BU/W<br />
O<br />
L2<br />
TRANSFORMER<br />
L1<br />
FOR USE ONLY<br />
ON AIR UNITS<br />
O<br />
BU<br />
LINE<br />
CONTROL BOX<br />
POTENTIAL RELAY<br />
HOT GAS VALVE<br />
24V<br />
BN<br />
1<br />
5<br />
6 4<br />
WATER VALVE<br />
START<br />
CAP<br />
FUSE<br />
Y/W<br />
2<br />
1 0<br />
O<br />
CONTACTOR<br />
COIL<br />
HI-PRESS<br />
CONTROL<br />
BU<br />
BU BU CONTROL<br />
V<br />
BK<br />
RELAY<br />
O<br />
CONTROL RELAY COIL<br />
R/W<br />
BN<br />
T1<br />
L1<br />
BK/W<br />
BK<br />
BK/W<br />
SUMP TEMP.<br />
SENSOR<br />
ELECTRONIC CONTROL<br />
RUN<br />
CAP<br />
4<br />
3<br />
4 5 6 7 1 2<br />
8 9<br />
3<br />
2<br />
1<br />
Y<br />
L2 T2<br />
CONTACTOR<br />
FUSE<br />
(3A)<br />
W<br />
7<br />
DISCHARGE<br />
TEMP.<br />
SENSOR<br />
November 2007<br />
Page 39<br />
WATER<br />
LEVEL<br />
SENSOR<br />
BIN<br />
FULL<br />
RCV.<br />
BIN<br />
FULL<br />
X-MIT<br />
W/R<br />
SUMP<br />
TEMP.<br />
BK BK<br />
6<br />
5<br />
DISCHARGE<br />
TEMP.<br />
7 1<br />
8 2<br />
11 5<br />
12<br />
6<br />
LOAD LINE<br />
V<br />
4<br />
ELECTRONIC<br />
CONTROL<br />
5<br />
3<br />
TRANSFORMER<br />
2<br />
BK Y R<br />
1<br />
3<br />
4<br />
2<br />
BIN FULL<br />
TRANSMITTER<br />
1<br />
BN BN<br />
3<br />
3<br />
2<br />
PROTECTOR<br />
INTERNAL<br />
1<br />
TERMINAL BOX<br />
GROUND<br />
SCREW<br />
5<br />
2<br />
4<br />
BIN FULL<br />
RECIEVER<br />
CONTROL<br />
RELAY<br />
R<br />
G/Y<br />
3<br />
S2<br />
C1<br />
JUNCTION<br />
BOX<br />
Y<br />
2<br />
WATER<br />
PUMP<br />
CONTACTOR T1<br />
1<br />
BK<br />
COMMUNICATIONS<br />
PORT<br />
1<br />
HI PRESSURE<br />
CONTROL<br />
1<br />
2<br />
R3<br />
3<br />
POWER SUPPLY<br />
W<br />
COMPRESSOR<br />
EARTH GROUND<br />
WATER<br />
LEVEL<br />
SENSOR<br />
SEE NAMEPLATE FOR<br />
PROPER VOLTAGE REQUIREMENTS<br />
AND MAXIMUM FUSE SIZE<br />
START<br />
CAP.<br />
POTENTIAL<br />
RELAY<br />
POTENTIAL<br />
RELAY COIL<br />
CAUTION:<br />
RUN<br />
CAP.<br />
MORE THAN ONE DISCONNECT MEANS MAY BE<br />
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.<br />
COMPRESSOR<br />
THIS UNIT MUST<br />
BE GROUNDED.
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
B or C Series, 50 Hz Air Cooled CME506 Diagram<br />
November 2007<br />
Page 40
<strong>CME256</strong> or CME506 or CME656 or CME806 Service <strong>Parts</strong><br />
D thru H Series, 50 Hz <strong>CME256</strong> Diagram<br />
November 2007<br />
Page 41