TECHNICAL DATA SHEET<br />
Page 1 of 4<br />
April 2004<br />
<strong>BASEFIX</strong> <strong>790</strong><br />
DESCRIPTION:<br />
Basefix <strong>790</strong> is a ready to spray clear sealer for various applications with basecoat/<br />
clearcoat systems and sensitive substrates. Its uses are:<br />
A. A fast drying clear for door jambs and interior parts.<br />
B. A clear insulating coat on sanded through areas.<br />
PRODUCT: Basefix <strong>790</strong><br />
REDUCERS: —Autocryl Reducer Fast: a fast flash reducer suitable for spot and panel repairs.<br />
Temperature ranges from 60°–75°F (16°–24°C).<br />
—Autocryl Reducer Medium: a medium temperature reducer for spot and panel<br />
repairs, also for larger areas. Temperature ranges from 70°–85°F (20°–30°C).<br />
—Sikkens Reducer SRA 7.0: a specially formulated solvent for spot repairs. May<br />
also be used in Basefix <strong>790</strong> at all temperature levels.<br />
BASIC RAW<br />
MATERIALS: Physically drying binders<br />
APPLICATION:<br />
SUITABLE<br />
SURFACES:<br />
APPLICATION<br />
METHOD &<br />
MIXING RATIO:<br />
A. Autobase ® Plus, after a flash-off time of 15 to 20 minutes (only for interior parts<br />
not exposed to direct sunlight).<br />
B. All existing finishes including lacquer after degreasing and sanding with #P500<br />
grit dry or #P800 grit wet (the fade out area must be scuffed with a grey scuffing<br />
pad). Any Sikkens primer surfacer after sanding with #P500 grit paper dry or<br />
#P800 grit wet.<br />
The application method and mixing ratio are dependent on the specific use of the<br />
product. Select the usage that is best for the job from A, or B or below, and follow<br />
the appropriate instructions:<br />
A. As an easy, fast drying clear to be applied over Autobase Plus for finishing<br />
doorjambs, interior parts and to cut in parts.<br />
Contains acrylic resins, toluene<br />
and other ingredients.<br />
1.<br />
2.<br />
Ready to spray<br />
Mixing Ratio: None
TECHNICAL DATA SHEET<br />
Page 2 of 4<br />
April 2004<br />
<strong>BASEFIX</strong> <strong>790</strong><br />
APPLICATION METHOD &<br />
MIXING RATIO (CONTINUED):<br />
A. As an easy, fast drying clear to be applied over Autobase Plus for finishing<br />
doorjambs, interior parts and to cut in parts.<br />
3.<br />
2–3x1<br />
HVLP Siphon<br />
0.071"–0.087" (1.8–2.2 mm)<br />
HVLP Gravity<br />
0.051"–0.059" (1.3–1.5 mm)<br />
Max. 10 psi (max. 0.8 bar)<br />
Application Method: Apply 2 to 3 single<br />
coats of Basefix <strong>790</strong> over Autobase Plus.<br />
4.<br />
5–10 minutes at 70°F (20°C)<br />
Allow 5–10 minutes flash-off time between<br />
coats.<br />
5.<br />
60 minutes at 70°F (20°C)<br />
The application (overspray) edge that<br />
occurs on the outside of the car part can be<br />
sanded smooth after 1 hour at 70°F (20°C).<br />
If desired, Basefix <strong>790</strong> can be polished<br />
when dry.<br />
B. A clear insulating coat on sanded through areas.<br />
(Method for sanded through area on second repair.)<br />
Prior to applying Basefix <strong>790</strong>, apply 3 light coats of primer surfacer Allow to dry.<br />
Sand with #P500 grit paper dry or #P800 grit wet.<br />
1.<br />
1b.<br />
2.<br />
1:1<br />
Basefix <strong>790</strong><br />
Autocryl Reducer Fast<br />
100:50<br />
Basefix <strong>790</strong><br />
Reducer SRA 7.0<br />
1–2x1<br />
HVLP Siphon0.071"–0.087"<br />
(1.8–2.2 mm)<br />
HVLP Gravity<br />
0.051"–0.059" (1.3–1.5 mm)<br />
Max 10 psi (max 0.8 bar)<br />
Mixing Ratio: Mix 100 parts by volume of<br />
Basefix <strong>790</strong> with 100 parts by volume of<br />
Autocryl Reducer Fast.<br />
OR ALTERNATIVELY-<br />
If using Sikkens Reducer SRA 7.0, mix 100<br />
parts by volume of Basefix <strong>790</strong> with 50<br />
parts by volume of Reducer SRA 7.0.<br />
Application Method: Apply one or two<br />
single coats of Basefix <strong>790</strong> with adequate<br />
flash-off time at least 3–5 minutes at 70°F<br />
(20°C). After the last coat is applied, allow<br />
15–20 minutes flash off time at 70°F (20°C)<br />
before proceeding with light coats of<br />
Autobase Plus. The Autobase Plus spot<br />
repair should stay within the area that is<br />
sealed with Basefix <strong>790</strong>.
TECHNICAL DATA SHEET<br />
Page 3 of 4<br />
April 2004<br />
<strong>BASEFIX</strong> <strong>790</strong><br />
(CONTINUED):<br />
B. A clear insulating coat on sanded through areas.<br />
(Method for sanded through area on second repair.)<br />
3.<br />
3–5 minutes at 70°F (20°C)<br />
Note: To improve curing prior to making a<br />
second repair on fresh paint jobs, apply an<br />
infrared heat lamp to the area before work<br />
is <strong>com</strong>menced.<br />
4.<br />
15–20 minutes at 70°F (20°C)<br />
5.<br />
Autobase Plus<br />
SPRAY GUN<br />
& PRESSURE:<br />
Spraying<br />
Fluid Tip<br />
Pressure<br />
Siphon Feed (1.4–1.7 mm) 40–50 psi<br />
Gravity Feed (1.3–1.4 mm) 40–50 psi<br />
HVLP Siphon (1.8–2.2 mm) max. 10 psi<br />
HVLP Gravity (1.3–1.5 mm) max. 10 psi<br />
CLEANING OF<br />
EQUIPMENT:<br />
RECOATABILITY:<br />
Clean the spray gun with Sikkens Cleaning Solvent <strong>790</strong> or lacquer thinner.<br />
Sanding will be<strong>com</strong>e necessary after 8 hours at 70°F (20°C).
TECHNICAL DATA SHEET<br />
Page 4 of 4<br />
April 2004<br />
<strong>BASEFIX</strong> <strong>790</strong><br />
STOCK KEEPING:<br />
COLOR:<br />
Clear<br />
CONTAINER SIZE: Basefix <strong>790</strong>:<br />
Autocryl Reducer:<br />
Sikkens Reducer SRA 7.0:<br />
1 quart (946 ml) and 1 gallon (3.785 lt)<br />
1 gallon (3.785 lt)<br />
1/2 gallon (1.89 lt)<br />
SHELF LIFE:<br />
Two years if stored in original container at room temperature.<br />
SAFETY ASPECTS:<br />
READY TO<br />
SPRAY VOC: As is: 6.1 lb/gal 730 g/liter<br />
1:1 with Autocryl Reducer: 6.8 lb/gal 815 g/liter<br />
100:50 with Reducer SRA 7.0 6.4 lb/gal 768 g/liter<br />
NOTICE:<br />
Do not handle until the Material Safety Data Sheets have been read and<br />
understood. Regulations require that all employees be trained on Material Safety<br />
Data Sheets for all chemicals with which they <strong>com</strong>e in contact. The manufacturer<br />
re<strong>com</strong>mends the use of an organic vapor respirator or air-supplied respirator when<br />
exposed to vapors or spray mist.