Instruments - American Orthodontics
Instruments - American Orthodontics
Instruments - American Orthodontics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
225<br />
<strong>Instruments</strong><br />
800.558.7687 | 920.457.5051
226<br />
<strong>Instruments</strong><br />
Enduring Excellence<br />
It is not enough for a cutter to be sharp or a bender to form<br />
wire. They must function consistently over time. <strong>American</strong><br />
<strong>Orthodontics</strong> delivers on this promise with its premium line of<br />
Omega Precision <strong>Instruments</strong>.<br />
Pleasing to the Eye and Hand<br />
Omega’s hand-polished, satin finish compliments the<br />
appearance of any modern office, while also reducing glare.<br />
Its contemporary, sleek design fits the hand comfortably and<br />
performs effortlessly.<br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
www.americanortho.com
227<br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
Ten Year Warranty<br />
A warranty this strong comes from a commitment to<br />
craftsmanship, which begins with quality materials and<br />
ends with precision manufacturing. Omega <strong>Instruments</strong><br />
are guaranteed to resist corrosion and breakage for<br />
10 years. Every Omega instrument is made from our<br />
uniquely formed DuraSteel TM forgings, providing excellence<br />
that endures the harsh environment of cleaning<br />
and sterilization. Each instrument is designed for a<br />
particular purpose, so Omega forging alloys are blended<br />
for that purpose. For example, cutters are designed to<br />
flex in the handle more than benders to provide a more<br />
comfortable shock absorber effect.<br />
The inserts for Omega cutters integrate<br />
seamlessly into the head of the cutter,<br />
repelling corroding elements and offering<br />
the perfect balance between sharpness<br />
and durability.<br />
<strong>Instruments</strong><br />
Precision Manufacturing<br />
Precision manufacturing can only be appreciated when<br />
handling different styles of Omega <strong>Instruments</strong>. Consistency<br />
in the functioning of the instrument as well as<br />
its fit and feel in the hand are what separates precision<br />
instruments from the rest of the field. Instead of spending<br />
time to find your favorite instrument, you can pick<br />
the one closest to you and feel confident that it fits your<br />
hand just the way you like it.<br />
All Omega Precision <strong>Instruments</strong> are<br />
laser marked for part identification and<br />
maximum wire capacity.<br />
Choosing the right steel<br />
Omega benders benefit from a slightly harder<br />
DuraSteel TM forging than Omega cutters. A<br />
harder handle offers firmer control and less<br />
flex than Omega cutters while a softer handle<br />
allows for more shock absorption when cutting<br />
wire. Omega cutters have proprietary highgrade<br />
stainless steel inserts for the cutting tips.<br />
These tips hold an excellent cutting edge and<br />
have superior corrosion resistance. The harder<br />
material also increases the endurance of the<br />
pliers’ wire contacting areas.<br />
RHC<br />
RHC 60<br />
RHC 51 or more<br />
40<br />
Cutter Bender Cutter<br />
handles handles tips<br />
Rockwell Hardness - RHC<br />
800.558.7687 | 920.457.5051
228<br />
<strong>Instruments</strong><br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
CUTTERS<br />
001-016E<br />
Distal End Cutter<br />
Safely cuts and securely holds distal ends of arch wire. Precise<br />
cutting edges and tip angle allow arch wires to be cut close to the<br />
distal end of tubes. Hardened inserted tips provide longer wear.<br />
Maximum cutting capacity is .021 x .025 wire.<br />
001-016LE<br />
Distal End Cutter - long handle<br />
Provides extended reach to the posterior regions of the mouth.<br />
Maximum cutting capacity is .021 x .025 wire.<br />
001-016ME<br />
Distal End Cutter - slim head<br />
Long, slim beaks make precise cutting and holding of arch wires<br />
effortless, even in hard to reach areas. Standard handle length.<br />
Maximum cutting capacity is .021 x .025 wire.<br />
001-016MLE<br />
Distal End Cutter - slim head and long handle<br />
Features a long, slim beak for precision cutting<br />
and holding of arch wires as well as an<br />
extended reach to the posterior regions.<br />
Maximum cutting capacity is .021 x .025 wire.<br />
001-016E<br />
001-016LE<br />
Omega Distal End Cutters<br />
are not recommended for<br />
multi-strand wires.<br />
001-016ME<br />
001-016MLE<br />
Handle comparison:<br />
Long handle option makes hard<br />
to reach areas more accessible.<br />
www.americanortho.com
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
CUTTERS<br />
229<br />
<strong>Instruments</strong><br />
001-001E<br />
001-002E<br />
001-001E<br />
Pin and Ligature Cutter<br />
Super sharp, diamond-honed edges cut cleanly, leaving no<br />
ragged edges. The workhorse of pin and ligature cutters.<br />
Maximum cutting capacity is .015 soft wire.<br />
001-002E<br />
Mini Pin and Ligature Cutter<br />
Finer tips than model 001-001E, for easier access to tight<br />
areas. Cuts even the smallest soft wire, ligatures, pins, and<br />
elastomerics.<br />
Maximum cutting capacity is .012 soft wire.<br />
001-003E<br />
Micro Pin and Ligature Cutter<br />
The finest tips available for cutting ligature wire, elastomerics,<br />
and other soft wire auxiliaries where access is at a premium.<br />
Maximum cutting capacity is .012 soft wire.<br />
001-003E<br />
007-001E<br />
Hard Wire Cutter<br />
The most durable cutter available.<br />
Capable of cutting any size pin, ligature, or wire up to .022 x .028.<br />
007-001E<br />
800.558.7687 | 920.457.5051
230<br />
<strong>Instruments</strong><br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
WIRE BENDING PLIERS<br />
001-300E<br />
NiTi Tie Back Pliers<br />
Revolutionary pliers tie back NiTi wire intraorally with no heat required. The<br />
precision tips also allow for other types of bends previously only possible in<br />
stainless steel. Not recommended for round wire.<br />
Maximum wire capacity is .021 x .025.<br />
001-139E<br />
Bird Beak Pliers<br />
Features a cone shaped beak opposed by a pyramid shaped beak. Tips are angled<br />
and all working edges are beveled to prevent scoring or nicking of the wire.<br />
Designed to work with round wire up to .030 diameter.<br />
001-142E<br />
Tapered Bird Beak Pliers<br />
Offers both the strength and durability of a traditional bird beak as well as the<br />
flexibility to bend light wires.<br />
Designed to work with wire up to .030 diameter.<br />
001-300E<br />
001-139E<br />
001-142E<br />
www.americanortho.com
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
WIRE BENDING PLIERS<br />
231<br />
<strong>Instruments</strong><br />
001-140E<br />
Light Wire Pliers<br />
Longer, more gradually tapered beaks than<br />
bird beak pliers. A round beak with a cone<br />
tip of .025” and a pyramid tip with 9° angle<br />
ground on the sides to allow for wire springback.<br />
Slender beaks make it easier to bend<br />
small diameter loops. The working edges are<br />
carefully beveled to prevent wire scoring.<br />
Maximum wire capacity is .020.<br />
001-810SE<br />
Tweed Style Rectangular<br />
Arch Bending Pliers<br />
Ideal for bending square and rectangular<br />
wire. Edges are radiused and hardened<br />
to prevent wire scoring and to preserve a<br />
smooth contact area with the wire.<br />
Maximum wire capacity is .0215 x .028.<br />
001-200E<br />
Three Jaw Pliers<br />
Features precision-aligned tips for consistent<br />
bends and gradual taper for delicate bends.<br />
One piece construction of the double tip<br />
ensures strength and eliminates flaring.<br />
Maximum wire capacity is .030.<br />
001-201E<br />
Three Jaw NiTi Pliers<br />
Gradual tapering for delicate bends. One<br />
piece construction of double tip for strength.<br />
Uniquely designed to form and contour<br />
nickel titanium wire, overcoming its shape<br />
memory at the point of contact.<br />
Maximum wire capacity is .020.<br />
001-140E<br />
001-810SE<br />
001-200E<br />
001-201E<br />
800.558.7687 | 920.457.5051
232<br />
<strong>Instruments</strong><br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
UTILITY PLIERS<br />
General utility pliers provide easy access to lingual and posterior areas. Carefully<br />
tapered and serrated beaks fit easily between brackets and are slightly rounded<br />
for safety and comfort.<br />
001-158E<br />
Weingart Pliers<br />
001-158LE<br />
Weingart Pliers - long handle<br />
001-158SE<br />
Weingart Pliers - slim beaks and standard length handle.<br />
001-158LE<br />
001-158E<br />
001-158SE<br />
Handle comparison:<br />
Long handle option makes hardto-reach<br />
areas more accessible.<br />
001-158E<br />
001-158LE<br />
www.americanortho.com
001-346E<br />
001-343E<br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
DEBONDING PLIERS<br />
001-346E<br />
Direct Bond Metal Bracket Remover<br />
These pliers are specially designed for quick and comfortable<br />
removal of direct bond metal brackets. Dual chisel tips wedge<br />
between the enamel/adhesive interface. May be used mesial-distal<br />
or occlusal-gingival.<br />
233<br />
<strong>Instruments</strong><br />
001-343E<br />
Radiance ®<br />
Bracket Debonding Pliers<br />
This instrument provides a unique option for debonding Radiance<br />
clear sapphire brackets. The tips are designed to grasp each Radiance<br />
bracket under the tie wing rather than making contact at the<br />
enamel/adhesive interface. These pliers are pre-adjusted with set<br />
screws to ensure that an optimal amount of pressure is applied to<br />
the bracket when the handles are squeezed together. To debond<br />
Radiance brackets, place the opposing tips of the pliers<br />
occlusal/gingival under the tie wings while applying constant<br />
pressure to the handles of the pliers. Gently move the angle of the<br />
instrument to the occlusal or gingival of the tooth with increasing<br />
force until the Radiance bracket releases from the tooth.<br />
001-408 Replacement tips (Qty. 2 with wrench)<br />
Tips are easily replaced and should be disinfected prior to use.<br />
Wedge tips between bracket<br />
base and tooth either mesial/<br />
distal or occlusal/gingival.<br />
Place opposing tips<br />
occlusal/gingival under the tie<br />
wings and gently angle instrument<br />
in one direction, either occlusally<br />
or gingivally.<br />
001-301E<br />
Ceramic Bracket Debonding Pliers<br />
Also known as Sushi pliers, this unique debonding instrument is<br />
specially designed for removing ceramic brackets. Only one edge of<br />
each blade is sharpened to ensure optimal fit along the enamel/adhesive<br />
interface. Opposing edges are parallel when the debonding<br />
instrument is open 3 mm, which is the average width of a ceramic<br />
bracket. Leave arch wires and ligatures in place during debonding.<br />
Remove adhesive flash from the mesial and distal edges of the<br />
bracket. Place debonding blades along the enamel/adhesive interface.<br />
Squeeze handles slowly until bracket releases from the tooth.<br />
001-301E<br />
Debonding blades are parallel<br />
when placed along mesial and<br />
distal sides of ceramic brackets,<br />
ensuring consistent debonding.<br />
Remove adhesive flash. Place<br />
tips mesial/distal along interface<br />
between tooth and adhesive and<br />
squeeze slowly.<br />
800.558.7687 | 920.457.5051
234<br />
<strong>Instruments</strong><br />
Ωmega<br />
®<br />
Precision <strong>Instruments</strong><br />
DEBONDING PLIERS<br />
Debonding pliers provide easy access to lingual and posterior areas.<br />
001-347LE<br />
Posterior Band Remover - with long beaks<br />
Ideal for posterior band removal. The padded tip rests on the occlusal<br />
of the molar cusp. Designed for better accessibility to distal area. 3/16“<br />
diameter heat sterilizable pad comes standard with the instrument.<br />
012-076 3/16” Replacement pads (Qty. 2)<br />
001-302<br />
Lingual Debonding Pliers<br />
Designed to remove lingual bonds such as lingual brackets and bite<br />
blocks. The unique design allows for easy and comfortable debonding.<br />
001-347LE<br />
001-344RTE<br />
Adhesive Removing Pliers<br />
Designed to easily remove adhesive remnants after debonding appliances.<br />
The stainless steel tip glides across the surface of the tooth<br />
using the counterforce of the interchangeable plastic pad to safely<br />
remove excess bonding material from enamel. 1/4” diameter heat<br />
sterilizable pad comes standard with instrument.<br />
012-077 1/4” Replacement pads (Qty. 2)<br />
001-407 Replacement metal tip insert (Qty. 1 with wrench)<br />
001-344RTE<br />
Example of easy removal<br />
of lingual bite blocks.<br />
001-302<br />
www.americanortho.com
235<br />
Produced with state-of-the-art CNC (Computerized Numerical Control) manufacturing<br />
equipment, Masterline instruments boast unmatched consistency, strength, and durability.<br />
Multiple instruments are shaped simultaneously, so each has a consistent feel, weight, and<br />
size. This unmatched consistency is particularly important to clinicians who cycle several sets<br />
of instruments through the sterilization process every day. Unlike instruments produced with<br />
traditional equipment, Masterline instruments have uniquely radiused corners to eliminate<br />
potential stress points, significantly reducing the risk of fracture.<br />
MasterLineTM<br />
INSTRUMENTS<br />
<strong>Instruments</strong><br />
Special high grade stainless steel forgings maximize corrosion resistance and enhance durability,<br />
greatly increasing longevity and ensuring smooth, easy function. The precise computerized<br />
milling process allows unprecedented tolerances - up to four digits. This<br />
precision virtually eliminates binding, avoids excessive play in the joint, and preserves the<br />
integrity of the working surface. Masterline instruments are hand buffed to a smooth,<br />
mirror finish, making instrument cleanup easy and further improving corrosion resistance.<br />
Masterline instruments are available<br />
in a wide variety of the most popular<br />
designs and configurations. Their unique<br />
qualities and features have established<br />
new standards for precision orthodontic<br />
instruments.<br />
Compare the hinge area of<br />
the Masterline (upper) and that<br />
of a competitive instrument.<br />
Masterline's radiused hinge<br />
corners eliminate stress points.<br />
Five Year Warranty<br />
<strong>American</strong> <strong>Orthodontics</strong> warrants its Masterline instruments to be<br />
free of defects in material and workmanship for five years. Misuse,<br />
abuse, or failure to properly maintain or care for the instrument<br />
will void warranty. Cutting instruments should be reconditioned<br />
every 6 - 9 months. Warranty does not cover routine maintenance,<br />
sharpening, or reconditioning.<br />
800.558.7687 | 920.457.5051
236<br />
<strong>Instruments</strong><br />
TM<br />
MasterLine<br />
CUTTERS<br />
001-016<br />
Safety Shear and Hold Distal End Cutter<br />
Safely cuts and securely holds distal ends of arch wires. Precise cutting edges and tip angle allow arch wires to be cut close to the<br />
distal end of buccal tubes. Hardened inserted tips provide longer wear.<br />
Maximum cutting capacity: .0215 x .028 stainless steel. Not recommended for nickel titanium wire.<br />
001-016L<br />
Safety Shear and Hold Distal End Cutter, Long Handle<br />
Long handle model facilitates access to hard-to-reach areas and provides extra cutting leverage - approximately .5”/1.5 cm longer. Precise<br />
cutting edges and tip angle allow arch wires to be cut close to the distal end of buccal tubes. Hardened inserted tips provide longer wear.<br />
Maximum cutting capacity: .0215 x .028 stainless steel. Not recommended for nickel titanium wire.<br />
001-016T<br />
Small Wire Safety Shear and Hold Distal End Cutter<br />
Modified tip designed for cutting and consistently holding high tensile stainless steel wires (up to .018). Recommended for cutting<br />
all sizes of nickel titanium wire.<br />
Maximum cutting capacity: .018 stainless steel wire. All sizes nickel titanium wire.<br />
001-010<br />
Distal End Cutter<br />
Allows arch wire to be cut almost flush with the distal end of buccal tubes eliminating potential irritation to patients.<br />
Maximum cutting capacity: .0215 x .028 stainless steel.<br />
001-001<br />
Standard Pin and Ligature Cutter<br />
Super sharp, diamond-honed edges cut cleanly, leaving no ragged edges to grind. The “workhorse” of pin and ligature cutters.<br />
Maximum cutting capacity: .015 soft wire.<br />
001-002<br />
Mini Pin and Ligature Cutter<br />
Finer tips than model 001-001, for easier access to tight areas. Cuts even the smallest soft wire, ligatures, pins, and elastomerics.<br />
A precise, yet sturdy instrument.<br />
Maximum cutting capacity: .012 soft wire.<br />
001-016<br />
001-016L<br />
001-016T<br />
001-001<br />
001-002<br />
001-010<br />
www.americanortho.com
007-001<br />
Hard Wire Cutter<br />
TM<br />
MasterLine<br />
CUTTERS<br />
Capable of cutting any size pin, ligature, or wire up to, and including, .0215 x .028. Inserted tips, made from specially hardened<br />
high-speed tool steel. The most durable cutter available.<br />
Maximum cutting capacity: .0215 x .028<br />
237<br />
<strong>Instruments</strong><br />
001-000HC<br />
Angled 15° Hard Wire Cutter - chrome<br />
Features a 15° cutting angle for easy access and better visibility. Particularly useful in cramped posterior areas.<br />
Maximum cutting capacity: .0215 x .028<br />
001-000HW<br />
Angled 15° Hard Wire Cutter - anodized black<br />
Features a 15° cutting angle for easy access and better visibility. Particularly useful in cramped posterior areas. Black color<br />
distinguishes hard wire cutter from pin and ligature cutters with smaller wire cutting capacity.<br />
Maximum cutting capacity: .0215 x .028<br />
001-006<br />
45° Ligature Cutter<br />
Allows easier access under tie wings to clip ligature wires. Excellent for use in posterior areas. Minimizes the risk of cheek impingement.<br />
Maximum cutting capacity: .012 soft wire.<br />
001-026<br />
Band Slitting Instrument<br />
Shear cuts upper and lower bands with a minimum of patient discomfort by gripping the incisal and gingival edges of the band,<br />
towards the interproximal, adjacent to the bracket. May also be used to remove direct bond attachments. Caution: avoid bracket<br />
flange and tie wing.<br />
007-001<br />
001-000HC<br />
001-000HW<br />
001-006<br />
001-026<br />
800.558.7687 | 920.457.5051
238<br />
<strong>Instruments</strong><br />
TM<br />
MasterLine<br />
WIRE BENDING PLIERS<br />
001-E140<br />
001-E140<br />
Light Wire Pliers<br />
Longer, more gradually tapered beaks than bird beak pliers (001-E139).<br />
A round beak with a cone tip of .025 and a pyramid tip with 9° angle<br />
ground on the sides to allow for wire springback. Slender beaks make it<br />
easier to bend small diameter loops. The working edges are carefully<br />
beveled to prevent wire scoring.<br />
Maximum wire capacity: .020<br />
001-E141<br />
001-E350<br />
001-E141<br />
Super Looper Light Wire Pliers - Begg Style<br />
Features two grooves at the tip for bending identical vertical loops and<br />
helices. The utility groove at the back is for closing loops. Accommodates<br />
round, square, and rectangular wire up to .020 diameter.<br />
Maximum wire capacity: .020<br />
001-E350<br />
Loop Forming Pliers - Tweed Style<br />
Capable of making “Bull” and helical closing loops in square and rectangular<br />
wire. Round beak has three step sections of .045, .060, and .075<br />
in diameter. Cylindrical beak is electro-etched to prevent wire slippage.<br />
Concave beak has slight parallel serrations to hold wire at 90° angle while<br />
forming loops. Replacement tips with Allen wrench available.<br />
Maximum wire capacity: .0215 x .028<br />
001-400 2 replacement tips and wrench<br />
001-E352<br />
001-E352<br />
Omega Loop Forming Pliers - Tweed Style<br />
A concave beak allows for easy, uniform Omega loops in square and<br />
rectangular wire. Round beak has three sections, each is .090 in length<br />
and .045, .060, .075 in diameter. Replacement tips with Allen wrench<br />
available.<br />
Maximum wire capacity: .0215 x .028<br />
001-400 2 replacement tips and wrench<br />
001-E139<br />
www.americanortho.com<br />
001-E139<br />
Bird Beak Pliers<br />
Features a “cone” shaped .025 beak, opposed by a “pyramid” shaped<br />
beak. Tips are angled at 9° to allow for wire springback. All working<br />
edges are beveled to prevent scoring or nicking of the wire. Designed to<br />
work with round wire up to .030 diameter.<br />
Maximum wire capacity: .030
001-051<br />
V-Bending Pliers<br />
Used for putting permanent centerline, anti-shift gable bends, and positive stops<br />
anywhere in nickel titanium arches.<br />
TM<br />
MasterLine<br />
WIRE BENDING PLIERS<br />
239<br />
<strong>Instruments</strong><br />
001-E410<br />
Lingual Arch Forming Pliers<br />
These pliers are designed to form terminal double-back and triple-back bends<br />
in either .030 or .036 wire for inserting in horizontal lingual sheaths. The blade<br />
width is the same .140 width of a lingual sheath.<br />
001-051<br />
001-E810S<br />
Rectangular Arch Forming Pliers - Tweed style short beaks<br />
Ideal for bending square and rectangular wire up to .0215 x .028. Edges are<br />
radiused and hardened to prevent wire scoring and to preserve a smooth contact<br />
area with the wire. Blades are parallel when opened to .020 to ensure accurate<br />
90° bends.<br />
Maximum wire capacity: .0215 x .028<br />
001-E410<br />
001-E810S<br />
001-E200<br />
Three Jaw Straight Pliers<br />
Features precision-aligned tips for consistent bends and gradual taper for delicate<br />
bends. One piece construction of the double tip ensures strength and eliminates<br />
flaring.<br />
Maximum wire capacity: .0215 x .028<br />
001-E200<br />
001-E355<br />
001-E355<br />
Jarabak Pliers<br />
These pliers are ideal for precise bending of lighter wires. Matching grooves in<br />
both beaks allow for accurate bending and closing of loops. Tips are serrated<br />
for sure grip.<br />
800.558.7687 | 920.457.5051
240<br />
<strong>Instruments</strong><br />
TM<br />
MasterLine<br />
WIRE BENDING PLIERS<br />
001-E110<br />
How Style Straight Utility Pliers<br />
Ideal for grasping all types of auxiliary attachments for fast and safe insertion. The center<br />
line of the 3/32 diameter pads coincides with the pliers’ axis of rotation. Matched serrated<br />
tips hold wire at any convenient working angle. Beaks are rounded for patient safety and<br />
comfort.<br />
001-E111<br />
How Style Offset Utility Pliers<br />
Incorporates the same features as the straight How pliers, but tips have a 45° angle for<br />
easy access to posterior intraoral areas.<br />
These Weingart pliers show the difference<br />
between a standard Weingart and a<br />
Weingart with the longer handles.<br />
001-E113<br />
Band Seating Pliers<br />
Designed to firmly grip bracket tie wings to aid in band seating. Capable of fitting between<br />
the smallest twin bracket, the square tips and strong beaks of these pliers allow for maximum<br />
gripping without scoring bracket wings.<br />
001-E8011<br />
Weingart 45°Utility Pliers<br />
Difficult to reach areas are made more accessible with the 45° angled tips. Serrated pads<br />
hold wires securely at a convenient angle. Tapered beaks are slightly rounded for safety<br />
and comfort.<br />
001-E158<br />
Weingart Pliers<br />
001-E158L<br />
Weingart Pliers - long handle<br />
General utility pliers provides easy access to lingual and posterior areas. Pointed, serrated<br />
pads are precision matched near center of rotation for better balance and sure grip.<br />
Carefully tapered beaks fit easily between brackets and are slightly rounded for safety<br />
and comfort.<br />
001-E158<br />
001-E8011<br />
001-E111<br />
001-E110<br />
001-E113<br />
www.americanortho.com
100-302<br />
Nance Loop Pliers<br />
Allows precision loop forming in rectangular wires. Both edges of this pliers'<br />
thin beaks are fully radiused and stepped at 3 mm, 4 mm, 5 mm, and 6 mm<br />
for forming various size loops.<br />
001-207<br />
Optical Style Pliers<br />
Ideal forming pliers for helical closing loops and arch adjustments. Thin concave<br />
beak ensures precise wire bends without nicking wire.<br />
WIRE BENDING PLIERS<br />
241<br />
<strong>Instruments</strong><br />
100-550<br />
Nance Tie Back Pliers<br />
These multipurpose specialty pliers are used for easily forming stops, tie<br />
backs, or Adams clasps for retainers.<br />
100-208<br />
Band Contouring Pliers<br />
Ideal for reshaping molar bands and forming arch wire bows.<br />
010-145<br />
Hollow Chop Pliers<br />
This contouring pliers’ mated concave and convex jaws are useful in<br />
reshaping arch wires and forming palatal arches.<br />
100-302<br />
001-E80516<br />
Rose Torquing Pliers - .016/.018 double end key<br />
001-E80518<br />
Rose Torquing Pliers - .018/.022 double end key<br />
Designed to place torque in a specific section of arch wire without distortion<br />
in the remainder of the wire. The pliers use a key (either .016/.018<br />
or .018/.022) that torques the section between holding beaks. Labial and<br />
lingual torque can be placed adjacent to each other easily. Torque can be<br />
limited to a single tooth.<br />
Replacement keys<br />
001-618 .016/.018 doubled ended<br />
001-822 .018/.022 doubled ended<br />
100-550<br />
001-207<br />
100-208<br />
001-E80516<br />
010-145<br />
800.558.7687 | 920.457.5051
242<br />
<strong>Instruments</strong><br />
TM<br />
MasterLine<br />
BRACKET REMOVERS<br />
001-E345RT<br />
001-E346RT<br />
001-E345RT<br />
Direct Bond Bracket Remover - narrow<br />
001-E346RT<br />
Direct Bond Bracket Remover - wide<br />
Narrow<br />
These pliers are specially designed for quick and comfortable removal of direct bond<br />
brackets. Dual chisel tips wedge between bracket base and tooth. May be used mesialdistally<br />
or incisal-gingivally.<br />
Wide<br />
001-406N NARROW: 2 replacement tips and wrench. Tip width: .070”/1.78 mm<br />
001-405 WIDE: 2 replacement tips and wrench. Tip width: .125”/3.18 mm<br />
001-E348RT<br />
Padded DB Bracket Remover - narrow<br />
001-E348RT<br />
001-E349RT<br />
001-E349RT<br />
Padded DB Bracket Remover - wide<br />
Narrow<br />
Designed for quick and comfortable removal of direct bond brackets. Can also be<br />
used to remove remaining adhesive. Pad rests on incisal surface and chisel tip wedges<br />
between bracket base and tooth. 3/16” diameter heat sterilizable pad comes standard<br />
with instrument. 1/4” diameter heat sterilizable pad also available individually.<br />
Heat sterilizable replacement pads<br />
012-076 3/16” (4.75 mm)<br />
012-077 1/4” (6.35 mm)<br />
Wide<br />
001-406N NARROW: 2 replacement tips and wrench. Tip width: .070”/1.78 mm<br />
001-405 WIDE: 2 replacement tips and wrench. Tip width: .125”/3.18 mm<br />
001-E301<br />
001-E301<br />
Direct Bond Bracket Remover<br />
Novel angulated “cutter” style bond remover design that is particularly effective with<br />
ceramic brackets. Cutter style debonding makes removing Radiance brackets even easier.<br />
Debonding blades are parallel<br />
when placed along mesial and<br />
distal sides of ceramic brackets,<br />
ensuring consistent debonding.<br />
001-302<br />
Lingual Debonding Pliers<br />
Designed to remove lingual bonds such as<br />
lingual brackets and bite blocks. The unique<br />
design allows for easy and<br />
comfortable debonding.<br />
001-302<br />
www.americanortho.com
001-2104<br />
Ligature Director<br />
For your choice and convenience, one end is straight and notched, the other end<br />
is angled. Fine tips make it ideal for working around mini brackets. Stainless steel.<br />
010-750<br />
Speedo Ligature Director and Remover<br />
Double ended stainless steel for placing and removing plastic ligatures.<br />
Reduces stress on newly bonded brackets during ligation.<br />
LIGATING INSTRUMENTS<br />
243<br />
<strong>Instruments</strong><br />
010-009<br />
Single End Explorer<br />
This explorer is extremely tough with excellent memory.<br />
Stainless steel spring wire.<br />
010-773<br />
Speedo Ligature Director<br />
Durable stainless steel with both ends used for placing<br />
plastic ligatures.<br />
001-101<br />
001-101S - with adjustable screw<br />
Force Module Separator<br />
Used to place anterior or posterior plastic separator modules.<br />
Contra angle beak reduces risk of tissue damage. Stainless steel.<br />
001-250C<br />
Coon Style Ligature Tying Pliers<br />
For the application and tying of ligatures, channel automatically locks wire<br />
ends as tips spread. For use with preformed steel ligatures. Stainless steel.<br />
010-009<br />
001-2104<br />
010-773<br />
010-750<br />
001-250C<br />
Use only cane-loaded ligatures<br />
with Speedo instruments.<br />
001-101<br />
800.558.7687 | 920.457.5051
244<br />
<strong>Instruments</strong><br />
TM<br />
MasterLine<br />
BAND REMOVERS<br />
001-026<br />
Band Slitting Instrument<br />
Shear cuts upper and lower bands with a minimum of patient discomfort by gripping the incisal and gingival<br />
edges of the band, towards the interproximal, adjacent to the bracket. May also be used to remove direct<br />
bond attachments. Caution: avoid bracket flange and tie wing.<br />
001-E347<br />
Posterior Band Remover - short beak<br />
Ideal for posterior band removal. When padded tip is on the occlusal of the molar, the removing tip is in an<br />
ideal position to catch the edge of the band. 3/16" diameter heat sterilizable pad comes standard with instrument;<br />
1/4" diameter heat sterilizable pad also available individually.<br />
Heat sterilizable replacement pads<br />
012-076 3/16” (4.75 mm)<br />
012-077 1/4” (6.35 mm)<br />
001-E347L<br />
Posterior Band Remover - long beak<br />
Designed for better accessibility to distal areas, these pliers are ideal for posterior band removal. 3/16”<br />
diameter heat sterilizable pad comes standard with instrument; 1/4” diameter sterilizable pad also available<br />
individually.<br />
Heat sterilizable replacement pads<br />
012-076 3/16” (4.75 mm)<br />
012-077 1/4” (6.35 mm)<br />
001-E347XL<br />
Posterior Band Remover - extra long beak<br />
The extra long beak introduces an even longer set of pliers for clinicians and chairside assistants, providing<br />
extra reach to the posterior region. The beak is approximately 25% longer and the handle is approximately<br />
20% longer than the “long beak” style of posterior band remover. 3/16” diameter heat sterilizable pad<br />
comes standard with instrument; 1/4” diameter sterilizable pad also available individually.<br />
Heat sterilizable replacement pads<br />
012-076 3/16” (4.75 mm)<br />
012-077 1/4” (6.35 mm)<br />
001-E347L<br />
001-E347<br />
001-E347XL<br />
001-026<br />
www.americanortho.com
100-107<br />
Surgical Hook Crimping Pliers<br />
TM<br />
MasterLine<br />
SPECIALTY INSTRUMENTS<br />
Two grooved inserts maintain a firm grip on the tube as it is delivered to the arch wire. Securely crimps tube<br />
at three points to prevent the ends from flaring.<br />
245<br />
<strong>Instruments</strong><br />
100-107A<br />
Arch Hook Crimping Pliers<br />
Two grooved inserts maintain a firm grip on the tube as it is delivered to the arch wire. Securely crimps the<br />
tube at three points to prevent the ends from flaring. Lower beaks are thinner to accommodate curvature of<br />
arch hook.<br />
100-109 .018 Slot<br />
100-111 .022 Slot<br />
Cap Removing Pliers<br />
Safely and easily removes convertible caps. Instrument places very little force on the tube, making it<br />
particularly effective with direct bond tubes.<br />
Replacement blades (5)<br />
100-110 .018 slot<br />
100-112 .022 slot<br />
001-E344RT<br />
Adhesive Removing Pliers<br />
Excess adhesive is easily removed after debonding with these specially designed pliers. The shorter beak<br />
features a stainless steel tip while the longer beak has a plastic interchangeable pad. 1/4” diameter heat<br />
sterilizable pad comes standard with instrument.<br />
012-077 Heat sterilizable replacement pads 1/4” (6.35 mm)<br />
001-407 Replacement tip and wrench. Tip dimension: .062”/1.57 mm<br />
001-E344RT<br />
100-107<br />
100-109<br />
100-111<br />
Securely crimps tube at<br />
three points<br />
100-107A<br />
800.558.7687 | 920.457.5051
246<br />
<strong>Instruments</strong><br />
BRACKET AND BAND PLACING INSTRUMENTS<br />
Direct Bond Bracket Holders<br />
001-100<br />
001-106 - Kit of 6<br />
For use with any bracket from a wide twin to a single.<br />
Reverse action holds bracket firmly and releases smoothly.<br />
001-800S - with curved tip<br />
Ideal for placing labial and lingual direct bond attachments due to its slight<br />
curve. Serrated tips and reverse action for positive holding.<br />
001-100A - with alignment tip<br />
This double ended instrument makes correct bracket placement easier by<br />
using the alignment tip in the arch wire slot and adjusting alignment. It<br />
can also be used for flash removal.<br />
678-212M - Hu-Friedy Direct Bond LP Tube Holder<br />
Designed to fit inside the positioning guides of LP Low Profile tubes and<br />
hold the tube securely during bonding at the posterior.<br />
001-100F - with fine tip<br />
Use this instrument for firmly holding smaller or mini brackets.<br />
001-100<br />
001-800S<br />
001-100A<br />
678-212M<br />
001-100F<br />
001-222<br />
Positive Positioner<br />
Designed to hold any direct bond attachment. Easy forward or backward<br />
releasing will not dislodge brackets. Lightweight, hard anodized aluminum.<br />
010-013<br />
Double Ended Band Seater<br />
Featuring sharp and distinct serrated tips on both ends for seating and<br />
contouring bands efficiently.<br />
861-210<br />
High Heat Bite Stick<br />
Hygienic and economical, this bite stick seats bands easily with a steel, triangular<br />
tip which allows easy access to interproximal area. Sold three per<br />
package. Heat resistant plastic can be used in all heat sterilizers up to 370°F.<br />
010-500<br />
Mallet Handled Band Pusher<br />
Offering superior control, the mallet handle and serrated tip provide a firm<br />
grip for pushing, burnishing, and seating bands.<br />
010-014<br />
6” College Tweezers<br />
A stainless steel multi-functional tweezers with longer, serrated tips.<br />
010-012<br />
Perry Dressing Tweezers<br />
This popular stainless steel multi-functional<br />
tweezers features serrated, angled tips.<br />
010-500<br />
001-222<br />
010-013<br />
861-210<br />
010-014<br />
www.americanortho.com<br />
010-012
010-776<br />
010-775M<br />
LIGATING INSTRUMENTS<br />
010-776<br />
Mathieu Needle Holder<br />
010-775M<br />
Mini Mathieu Needle Holder<br />
A Mathieu with tapered, serrated tips specially designed for ligature<br />
application. Super fine tip and short beaks allow ligatures to<br />
be firmly gripped without intruding into the lumen.<br />
Stainless steel with locking handle.<br />
247<br />
<strong>Instruments</strong><br />
010-775<br />
Mathieu Needle Holder<br />
010-775<br />
010-775N<br />
010-8015<br />
010-775N<br />
Mathieu Needle Holder - narrow<br />
For easy application of ligatures. Serrations along entire length<br />
of tip allow for application of chain elastics as well as ligatures.<br />
Stainless steel with locking handle.<br />
010-8015<br />
Smaha Forceps - straight<br />
Ultra thin straight tips are especially useful for placement in difficult<br />
areas. Stainless steel with serrated tips and locking handle.<br />
010-771<br />
Hemostat<br />
5" straight hemostatic forceps. Stainless steel with serrated tips<br />
and locking handle.<br />
010-772<br />
Hemostat - fine tip<br />
4 3/4" straight mosquito hemostatic forceps. Stainless steel with<br />
serrated tips and locking handle.<br />
010-771 010-772<br />
800.558.7687 | 920.457.5051
248<br />
SPECIALTY INSTRUMENTS & ACCESSORIES<br />
<strong>Instruments</strong><br />
100-400<br />
001-501<br />
010-008<br />
001-505 - Small<br />
001-506 - Large<br />
Distal Twister TM<br />
Cinchback bends are quick and easy by inserting the tip over<br />
the distal end of the arch wire and twisting in the desired<br />
direction. Small size is ideal for wire sizes up to .018 round and<br />
square sizes up to .016 x .016. The large will accommodate<br />
round wire up to .020, and rectangular wire up to .021 x .025.<br />
100-400<br />
Adjustable Enamel Stripper<br />
010-015<br />
001-102<br />
Specially designed and developed for easy, efficient removal<br />
and recontouring of the interproximal tooth enamel, for the<br />
widening of contact points or for the removal of overhanging<br />
fillings. Sterilizable.<br />
Kit: Includes enamel stripper, 12 single and double sided steel<br />
strips of assorted grits, instructions<br />
Replacement steel strips, single sided grit<br />
100-401 12 fine grit<br />
010-751<br />
100-402 12 medium grit<br />
100-403 12 coarse grit<br />
001-505<br />
100-700<br />
100-700<br />
Convertible Cap Remover<br />
For ease in removing the convertible caps on molar tubes.<br />
Replacement blades are available.<br />
100-701 10 replacement blades<br />
010-015<br />
Alexander Bracket Placement Guide<br />
Approximates correct vertical height of bracket placement.<br />
Provides vertical placement options of 3.5 mm, 4.0 mm, 4.5<br />
mm, and 5.0 mm depending on tooth.<br />
001-501<br />
Dontrix Gauge<br />
Measures the force of coil springs and elastics up to 16<br />
ounces. Marked in one ounce increments.<br />
010-008<br />
Spatula<br />
Single ended stainless steel with a combination of flexibility<br />
and strength for mixing cement. Smooth, highly polished<br />
surface makes cleanup easy.<br />
001-102<br />
Direct Bond Adhesive Remover<br />
Double ended curved tips for scraping adhesive in hard to<br />
reach places.<br />
010-751<br />
Band Seater/Cement Scaler<br />
Serrated band seating tip on one end and curved tip on the<br />
other end for scraping excess adhesive.<br />
www.americanortho.com
010-011<br />
Stainless Steel Mouth Mirror<br />
Durable stainless steel, front surface mirror.<br />
861-099<br />
Plastic Mouth Mirror<br />
SPECIALTY INSTRUMENTS & ACCESSORIES<br />
Made from durable disposable white nylon with precision ground glass mirror for low<br />
distortion. 24 pieces per package.<br />
010-011<br />
861-099<br />
007-005<br />
249<br />
<strong>Instruments</strong><br />
007-005<br />
Heavy Duty Wire Cutter<br />
Ideal for cutting facebows - both inner and outer bows. Well honed cutting edges<br />
will not nick the wire. Blades will lock in closed position for safe storage. Features a<br />
hard chrome finish for a more professional look and soft vinyl grips for comfort and<br />
leverage. Another "must" for every office and lab.<br />
Maximum cutting capacity: .080" diameter stainless steel.<br />
010-835<br />
Pliers Rack<br />
White plastic rack holds instruments with tips up for easy identification.<br />
Cold sterilize. 5 1/2” x 9” x 4 3/4” (13.75 cm x 22.5 cm x 11.88 cm)<br />
010-836<br />
Instrument Tray<br />
White plastic tray has 7 compartments that hold instruments conveniently and a<br />
multipurpose storage tray. Cold sterilize. 2 1/8” x 6 3/16” x 8” (5.4 cm x 15.8 cm x 20 cm)<br />
010-010<br />
Boone Gauge<br />
Measures for bracket height. Flat surface rests on incisal/occlusal surface of tooth.<br />
Fixed pin scribes mark for bracket heights of 3.5 mm, 4 mm, 4.5 mm and 5 mm.<br />
001-6015<br />
Medic 365 Instrument Lubricant<br />
Synthetic lubricant and preservative for instruments that offers<br />
water repellent surface protection and resistance to heat<br />
and oxidation. Available in an 8 ounce dropper bottle.<br />
010-101<br />
Micrometer<br />
Direct reading from .0001 to 1 inch.<br />
001-6015<br />
010-835<br />
010-010<br />
010-101<br />
010-836<br />
800.558.7687 | 920.457.5051
250<br />
<strong>Instruments</strong><br />
INSTRUMENTS FOR SELF LIGATING BRACKETS<br />
Empower Instrument<br />
678-901E - Single prong tip for opening using gingival tail of clip. Double prong tip for<br />
opening using facial hole or for pressing wire into bottom of slot during clip closing.<br />
Vision LP <strong>Instruments</strong><br />
678-901 - single ended for brackets<br />
678-901H - double ended for brackets<br />
678-901MB - double ended for molars and brackets<br />
010-902 - double ended for molars and brackets (optional style)<br />
T3 <strong>Instruments</strong><br />
010-255 - T3 open/close Instrument<br />
010-255S - T3 open/close instrument, short<br />
678-903 - Hu-Friedy open/close instrument<br />
GK-5013 - Hu-Friedy T3 positioning instrument<br />
010-255S<br />
010-255<br />
678-903<br />
GK-5013<br />
678-901<br />
678-901H<br />
901MB<br />
010-902<br />
678-901E<br />
www.americanortho.com
INSTRUMENT CARE<br />
251<br />
Preventing Corrosion<br />
Corrosion can attack any stainless steel<br />
instrument from any manufacturer. A<br />
little effort to ensure the cleanliness<br />
of the part during sterilization goes a<br />
long way.Stainless steel surfaces require<br />
access to oxygen to form a protective<br />
chromium oxide layer. This chromium<br />
oxide layer (passive layer) is what gives<br />
stainless steel its corrosion resistance.<br />
Instrument care and repair<br />
It is important to follow strict procedures in the care and maintenance of your<br />
instruments. To assure the longevity and corrosion resistance of your investment,<br />
follow one of these sterilization methods. NOTE: Be sure to read your sterilization<br />
unit’s instruction manual for proper set-up and to adjust for local water conditions.<br />
Always follow your unit’s sterilization parameters.<br />
Dry Heat Sterilization:<br />
1. Remove any debris from instruments using a brush or towel.<br />
2. Perform an ultrasonic cleaning using a general purpose cleaner.<br />
3. Dry thoroughly with oil/water-free compressed air or towel.<br />
4. Place instruments on racks.<br />
5. Sterilize following parameters given by sterilization unit manufacturer.<br />
6. Lubricate immediately with a silicone-based lubricant.<br />
<strong>Instruments</strong><br />
What prevents oxygen from contacting<br />
stainless steel? Moisture, dirt, and<br />
cement left on the instrument are typical<br />
causes that prevent oxygen from contacting<br />
stainless steel during the<br />
sterilization process. <strong>Instruments</strong> should<br />
be thoroughly brushed clean before<br />
sterilization. All instruments should be<br />
sterilized in the open position and then<br />
thoroughly dried after sterilization,<br />
taking special care in the joint areas and<br />
crevices.<br />
Corroded instruments should never be<br />
sterilized with non-corroded instruments<br />
as the iron oxide on the corroded instrument<br />
can transfer to the non-corroded<br />
instrument, attaching itself permanently.<br />
Autoclaving:<br />
1. Remove any debris from instruments using a brush or towel.<br />
2. Perform an ultrasonic cleaning using a general purpose cleaner.<br />
3. Dry thoroughly with oil/water-free compressed air or towel.<br />
4. Place instruments on autoclave tray with jaws open.<br />
5. Sterilize following parameters given by sterilization unit manufacturer.<br />
6. Allow instruments to cool after sterilization cycle.<br />
7. Remove instruments and ensure instruments are free of moisture by towel drying.<br />
8. Lubricate immediately with a silicone-based lubricant.<br />
Chemclaving (unsaturated chemical vapor):<br />
1. Remove any debris from instruments using a brush or towel.<br />
2. Perform an ultrasonic cleaning using a general purpose cleaner.<br />
3. Dry thoroughly with oil/water-free compressed air or towel.<br />
4. Place instruments on chemclave tray with jaws open. Place layer of paper<br />
toweling between instruments.<br />
5. Sterilize following parameters given by sterilization unit manufacturer.<br />
6. Depressurize the equipment and allow instruments to cool after sterilization cycle.<br />
7. Remove instruments and ensure instruments are free of moisture by towel drying.<br />
8. Lubricate immediately with a silicone-based lubricant.<br />
Cold Sterilization (disinfection):<br />
1. Remove any debris from instruments using a brush or towel.<br />
2. Perform an ultrasonic cleaning using a general purpose cleaner.<br />
3. Dry thoroughly with oil/water-free compressed air or towel.<br />
4. Immerse instruments in a 2% glutaraldehyde sterilizing solution.<br />
5. Remove the instruments from the sterilizing solution, rinse in water, and towel<br />
dry to ensure instrument is free of moisture.<br />
6. Lubricate immediately with a silicone-based lubricant.<br />
Helpful Hint: Dipping instruments in a water-based surgical milk prior to ultrasonic<br />
cleaning reduces the incidence of spots, stains, and corrosion. Surgical<br />
milk is an interface surface corrosion inhibitor and lubricant that helps to ensure<br />
proper movement of hinges and provides a protective barrier that arrests<br />
discoloration and corrosion during sterilization.<br />
800.558.7687 | 920.457.5051
252<br />
<strong>Instruments</strong><br />
INSTRUMENT CARE<br />
INSTRUMENT RECONDITIONING AND REPAIR PROGRAM<br />
<strong>Instruments</strong> need regular preventative check ups. To preserve the accuracy and extend the life of your instruments,<br />
it's important to recondition them every 6 to 9 months. <strong>American</strong> <strong>Orthodontics</strong> offers precise sharpening, retipping,<br />
and reconditioning/polishing of your instruments in a timely manner. We also recondition and repair instruments<br />
from other manufacturers (excluding Hu-Friedy).<br />
000-030 Sharpen<br />
000-031 Retip<br />
000-032 Recondition<br />
(may include joint adjustment, reserrating, and polishing)<br />
www.americanortho.com