Vanguard 76pg Catalog - HVTEST South Africa
Vanguard 76pg Catalog - HVTEST South Africa
Vanguard 76pg Catalog - HVTEST South Africa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
H.V. TEST (PTY) LTD<br />
3 Gaiety Ave, Robindale, Randburg, <strong>South</strong> <strong>Africa</strong>, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770<br />
P.O. Box 651287, Benmore, 2010 Email: sales@hvtest.co.za Website: www.hvtest.co.za
GHI<br />
PQRS<br />
ENTER<br />
ABC<br />
JKL<br />
TUV<br />
DEF<br />
MNO<br />
WXYZ<br />
TM<br />
START<br />
PAPER<br />
CONTRAST<br />
CONTRAST<br />
PAPER<br />
120/240 Vac, 1A, 50-60Hz<br />
Fuse: 250Vac, 2A Fast-Blow<br />
I<br />
O<br />
Simplify the<br />
<strong>Vanguard</strong> Instruments Co., Inc.<br />
Ontario, California, USA<br />
!<br />
TRIGGER<br />
(300V MAX)<br />
CT-3500 TM<br />
Digital Circuit Breaker Timer<br />
GROUND<br />
RS-323C<br />
1 2 3<br />
4 5 6<br />
7 8 9<br />
CONTACT<br />
CT-3500<br />
0 CLEAR STOP<br />
LKNZ<br />
SERIAL #<br />
MADE IN U.S.A.<br />
<strong>Vanguard</strong> Instrument’s Model CT-3500 is a second generation, stand-alone, digital,<br />
microprocessor-controlled, circuit-breaker timer. It measures elapsed time from the<br />
instant a breaker coil is energized to the instant of opening or closing of a circuitbreaker’s<br />
dry contacts. The CT-3500 not only times the breaker’s contact response<br />
time, but it can also time relays or other switching function that use an initiating-trigger<br />
voltage (24-300 Volts dc or ac). The timer-triggering voltage starts three independent<br />
electronics timers, each of which is individually stopped by its respective drycontact<br />
closing or opening. The CT-3500 fully analyzes the timing of breaker contact<br />
operations: OPEN, CLOSE, OPEN-to-CLOSE, and CLOSE-to-OPEN. Timing results, in<br />
milliseconds and cycles, display on a 4-line by 20-character backlit LCD. A built-in<br />
2.5-inch-wide thermal printer provides a hard copy of test report. A real-time clock<br />
allows test results to be dated and time stamped for record keeping.<br />
Contact Timing Inputs<br />
The CT-3500 features three dry-contact, timer-channel monitoring. The dry-contact<br />
channel power supply is fuse protected. All inputs are shunted to ground until the<br />
instant of test. Inputs are Zener-protected against static discharge. A contact self-test<br />
cable-mode lets users test cables or connections to the breaker when required.<br />
User Interface<br />
A built-in thermal printer prints test reports on 2.5-inch-wide thermal paper. An<br />
alphanumeric keypad lets users enter test information and control functions. Timing<br />
results, in milliseconds and cycles, display on a 4-line by 20-character backlit LCD.<br />
Timing Shot Storage<br />
Up to 128 timing records can be stored in the CT-3500 FLASH EEPROM. The<br />
user can recall stored test reports to be printed or transferred to an IBM-compatible<br />
PC. An RS-232C serial-interface port also provides for computer interface<br />
and diagnostic test. A Windows based software package (provided with each<br />
unit) allows the user to down load test records to a PC. The user can then<br />
review, print or export test records.<br />
+<br />
RED BLK RED BLK RED BLK<br />
(9) (7)<br />
TC<br />
CC<br />
A<br />
B<br />
C<br />
–<br />
FEATURES<br />
CONTROL CIRCUIT<br />
• Timing Results Display in Milliseconds & Cycles.<br />
• Timing results from all three Timers are shown simultaneously on a backlit LCD<br />
• Backlit LCD for easy data readout in bright sunlight outside or inside<br />
• Fully analyzes all breaker operation: Open, Close, Open-Close, Close-Open<br />
• Built-in 2.5" Thermal printer • Stores 128 timing records<br />
Digital Circuit Breaker Analyzer<br />
H.V. TEST (PTY) LTD<br />
3 Gaiety Ave, Robindale, Randburg, <strong>South</strong> <strong>Africa</strong>, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770<br />
P.O. Box 651287, Benmore, 2010 Email: sales@hvtest.co.za Website: www.hvtest.co.za
Timing<br />
of EHV Circuit Breakers, Relay<br />
Operations and Switching Gear<br />
Trigger<br />
Input<br />
Connector<br />
Backlit<br />
4-line x 20 Character<br />
LCD Display<br />
2.5-inch<br />
Thermal<br />
Printout<br />
Printed Test Results<br />
Contact<br />
Input<br />
Connector<br />
RS-232C<br />
Interface<br />
Rugged<br />
16-Key<br />
Keyboard<br />
TYPE<br />
PHYSICAL SPECIFICATIONS<br />
INPUT POWER<br />
DRY CONTACT INPUT<br />
TRIGGER INPUT VOLTAGE<br />
TEST OPERATIONS<br />
TIMING RESOLUTION<br />
TIMING ACCURACY<br />
DISPLAY<br />
PRINTER<br />
KEYBOARD<br />
TEST RECORD STORAGE<br />
COMPUTER INTERFACE<br />
PC SOFTWARE<br />
SAFETY<br />
ENVIRONMENT<br />
CABLES<br />
SPECIFICATIONS<br />
OPTIONS<br />
WARRANTY<br />
Special-purpose utility test equipment, digital Circuit-Breaker Timer<br />
15" W by 7”H by 13" D (38.1 cm x 17.8 cm x 33.0 cm); Weight, less than 15 lbs (6.8 kg)<br />
85 to 132 Vac or 200-240 Vac (selectable), 50/60 Hz<br />
3 channels<br />
Open/Close: 30-300 V, dc/peak ac<br />
Open, Close, Open-Close, Close-Open<br />
± 1/10 millisecond<br />
0.05% of reading ± 0.1ms<br />
LCD, Backlit, 4 line Screen by 20 character, Viewable in sunlight<br />
2.5-inch Thermal Printer<br />
Heavy-duty keypad: 10 number keys, 6 function keys<br />
Store 128 Timing Records<br />
RS-232C Port, 19,200 Baud<br />
Windows ® 95/98/NT/2000/XP-Based, included with purchase price<br />
Designed to meet IEC61010 (1995), UL61010A-1, CSA-C22.2<br />
Operating: -10˚C to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚F to +158˚ F)<br />
(1) 20-ft Contact Test Lead Cable, (1)Trigger cable with Extension Cable;<br />
(1) Grounding Cable with attaching clips; (1) Cable Carrying Bag; (1) Power cord<br />
Hard case with air-foam liner–Recommended for shipping<br />
One Year Parts & Labor, Post-Warranty Service available<br />
Note: The above specifications are valid at nominal voltage and ambient temperature of +25°C (+77°F). Specifications are subject to change without notice.<br />
H.V. TEST (PTY) LTD<br />
3 Gaiety Ave, Robindale, Randburg, <strong>South</strong> <strong>Africa</strong>, 2010 Tel: +27(11) 782 1010 Fax: +27(11) 782 2770<br />
P.O. Box 651287, Benmore, 2010 Email: sales@hvtest.co.za Website: www.hvtest.co.za