<strong>Wallis</strong> <br />

<strong>Zeta</strong> potential analyzer<br />

<strong>High</strong>-<strong>Resolution</strong> <strong>Zeta</strong> <strong>Potential</strong> <strong>Analysis</strong><br />

IDEAL FOR<br />

Formulation stability<br />

Nanoparticle<br />

Emulsions<br />

Pharmaceuticals<br />

Petrochemicals<br />

Polymers<br />

Liposomes and bio-colloids<br />

Pigments and inks<br />

… and more<br />

www.cordouan-tech.com


The <strong>Wallis</strong> <br />

»<br />

• <strong>Zeta</strong> potential : -200200mV<br />

• Particle size : 1nm 100µm<br />

• Concentration range : 0.0001 10%/w<br />

<strong>Zeta</strong> potential<br />

unstable? / stable?<br />

Particles in solution are surrounded by an<br />

Electrical Double Layer (EDL) that characterizes<br />

particle-particle interaction. It fully determines<br />

the formulation stability. The measurement of<br />

<strong>Zeta</strong> potential is directly related to particle<br />

charge environment and then inform about<br />

dispersion stability. It is widely use for chemical<br />

synthesis, particle functionalization…etc.<br />

Measure <strong>Zeta</strong> potential !<br />

Dowload the technical note.<br />

» www.cordouan-tech.com<br />

Measurement cell: simple, robust, artefact free<br />

Simple: The dip cell design allows<br />

simple sample injection and prevent<br />

bubble formation. It is compliant with<br />

standard cuvette cell for multiple<br />

analysis benchmarking. Its design<br />

makes it fully compatible with organic<br />

solvent<br />

Robust: The innovative vitreous carbon electrode provides<br />

long life and stability to the electrodes that can be easily<br />

cleaned by standard process like sonication or acid-base<br />

washing.<br />

dip cell = no electro-osmosis<br />

Artefact free: <strong>Zeta</strong> potential is directly related to electrokinetic phenoma like<br />

electrophoretic mobility. The dip cell electrodes design prevents electro-osmosis<br />

during measurement giving accurate results without « mysterious » software<br />

correction.


Robust & easy to handle technology led to its best performance:<br />

10 times more resolution than usual correlation technology<br />

No electro-osmosis<br />

In-field proven technology (LDE)<br />

New & unique electrode material for long life material.<br />

Easy to use measurement cuvettes<br />

Compatible with organic solvents and high-pH suspensions<br />

<strong>High</strong> quality data for accurate and repeatable zeta potential analysis and interpretation.<br />

Easy to use and intuitive graphical user interface (GUI) software.<br />

Usual<br />

method<br />

Raw<br />

data<br />

<strong>Cordouan</strong>’s<br />

method<br />

<strong>High</strong> resolution measurement<br />

WALLIS-ζ is a high resolution <strong>Zeta</strong><br />

potential analyzer. Using dedicated<br />

data acquisition and analysis, it<br />

provides the following unique high<br />

resolution features:<br />

Electrophoretic mobility up to<br />

10 -10 m²/V.s resolution<br />

<strong>Zeta</strong> potential up to 0,1 mV<br />

resolution (in water)<br />

<strong>Zeta</strong> potential<br />

<strong>Zeta</strong> potential<br />

Intuitive GUI software<br />

10 times higher resolution<br />

<strong>High</strong> performances for<br />

advanced measurements<br />

<strong>High</strong> resolution of <strong>Wallis</strong> allow high<br />

quality measurement for:<br />

‣ Precise measurement of IEP<br />

‣ Accurate functionnalization of<br />

colloid<br />

‣ Repeatability of particles synthesis<br />

‣ Advanced particles stability analysis


<strong>Wallis</strong> <br />

<strong>Zeta</strong> potential analyzer<br />

<strong>Zeta</strong> <strong>Potential</strong> <strong>Zeta</strong> potential range -200 mV to 200 mV<br />

Signal<br />

processing<br />

Mobility range<br />

Sample concentration<br />

Cell options<br />

Sample volume<br />

Maximum sample conductivity<br />

Sample Type<br />

Measurement technology<br />

Laser source<br />

10 -10 to 10 -7 m 2 /V.s<br />

0.0001% to 10% w/% (solvent dependent)<br />

Cuvette cell with optical quality windows compatible with organic solvents<br />

Typically 750 µL (Hellma cell – 10 mm light path)<br />

300 mS/cm<br />

Aqueous & organic solvents – pH: 1-14 (depending on cuvette cell material)<br />

Laser Doppler Electrophoresis (LDE)<br />

20 mW diode @635 nm coupled to automated attenuation system. Other<br />

wavelengths available upon request<br />

Measurement angle Single angle for zeta potential at 17°<br />

Data processing algorithm<br />

<strong>Resolution</strong><br />

Detector<br />

Fast Fourier Transform<br />

Mobility = 10 -10 m 2 /V.s or <strong>Zeta</strong> = 0,1 mV ( in water)<br />

Avalanche Photodiode – APD<br />

General Temperature control range inside the cell 10°C to 90°C +/-0,1°C (depending on cuvette cell material)<br />

System<br />

Compliance<br />

Computer interface<br />

Dimensions<br />

Weight<br />

Power<br />

CE certification<br />

ISO norm<br />

USB 2.0 – Windows XP, Seven<br />

45 cm x 30 cm x 40 cm (HWD)<br />

17 kg<br />

100/115/220/240 VAC, 50/60 Hz, 100 W max<br />

CE marked product - Class I laser product, EN 60825-1:2001, CDRH<br />

ISO 13099-2 : 2012 – Colloidal system – methods for zeta-potential<br />

determination – Part 2 : Optical methods<br />

Contact:<br />

sales@cordouan-tech.com<br />

service@cordouan-tech.com<br />

11, avenue de Canteranne<br />

33600 Pessac – France<br />

Tel +33 (0)556 158 045<br />

Fax +33 (0)547 747 491