Power duration measurements<br />

Power duration measurements record the elapsed time after the introduction of a power step until the output is<br />

attenuated to a safe power level by the onboard protection system (Please refer to page 12 for a full<br />

description). Measurements marked with * indicate loss of output power.<br />

• Stepping the power load on the <strong>ASP</strong>-module<br />

Module Input Frequency Preload power Stepped power<br />

500<strong>ASP</strong> 880 Hz 250 W @ 4Ω 500 W @ 4Ω<br />

500A 1.52 kHz 125 W @ 4Ω 125 W @ 4Ω<br />

250A 1 kHz 125 W @ 2.7Ω 125 W @ 2.7Ω<br />

Power duration [ms] (t 150 )<br />

500<strong>ASP</strong> 500A 250A<br />

50 Volt bus w/o extra capacitor 80 Volt bus w/o extra capacitor 33 > 2000 > 2000<br />

50 Volt bus w/o extra capacitor 80 Volt bus with extra capacitor 9600uF 80 > 2000 > 2000<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus w/o extra capacitor 51 > 2000 > 2000<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus with extra capacitor 9600uF 97 > 2000 > 2000<br />

• Stepping the power load on the 500A hanger module<br />

Module Input Frequency Preload power Stepped power<br />

500<strong>ASP</strong> 880 Hz 125 W @ 4Ω 125 W @ 4Ω<br />

500A 1.52 kHz 250 W @ 4Ω 500 W @ 4Ω<br />

250A 1 kHz 125 W @ 2.7Ω 125 W @ 2.7Ω<br />

Power duration [ms] (t 150 )<br />

500<strong>ASP</strong> 500A 250A<br />

50 Volt bus w/o extra capacitor 80 Volt bus w/o extra capacitor 36* 36 1000*<br />

50 Volt bus w/o extra capacitor 80 Volt bus with extra capacitor 9600uF 89* 80 169*<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus w/o extra capacitor 57* 52 404*<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus with extra capacitor 9600uF 108* 98 143<br />

• Stepping the power load on the 250A hanger module<br />

Module Input Frequency Preload power Stepped power<br />

500<strong>ASP</strong> 880 Hz 250 W @ 4Ω 250 W @ 4Ω<br />

500A 1.52 kHz 250 W @ 4Ω 250 W @ 4Ω<br />

250A 1 kHz 0 W @ 2.7Ω 250 W@2.7Ω<br />

Power duration [ms] (t 150 )<br />

500<strong>ASP</strong> 500A 250A<br />

50 Volt bus w/o extra capacitor 80 Volt bus w/o extra capacitor 32 > 2000 83*<br />

50 Volt bus w/o extra capacitor 80 Volt bus with extra capacitor 9600uF 79 > 2000 250*<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus w/o extra capacitor 50 > 2000 150*<br />

50 Volt bus with extra capacitor 9600uF 80 Volt bus with extra capacitor 9600uF 96 > 2000 156*<br />