INDC(SEC)-46/U+R+F+SIN DC INTERNATIONAL NUCLEAR DATA ...
INDC(SEC)-46/U+R+F+SIN DC INTERNATIONAL NUCLEAR DATA ...
INDC(SEC)-46/U+R+F+SIN DC INTERNATIONAL NUCLEAR DATA ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
45 SCANDIUM 45 NEUTRCN CAPTURE CROSS <strong>SEC</strong>TION (CONTINUED)<br />
2=O 3 MV 4o OC KEV M c N , N IK OL A E V FE I<br />
CAPTURE wIDTH OF 2-9 KEV RESONANCE SHOULD BE<br />
MEASURED IN THREE DIFFERENT EXPERIMENTS. RESULTS<br />
SHOULD COINCIDE WITHIN LIMITS OF 5-7 PERCENTo<br />
IF HIGH RPI CAPTURE WIDTH CONFIRMED, ENERGY<br />
DEPENDENCE OF CAPTURE CROSS <strong>SEC</strong>TION SHOULD BE<br />
MEASURED FROM THERMAL TO RESONANCE REGION TO<br />
INVESTIGATE INTERFERENCE BETWEEN DIRECT AND<br />
RESONANCE CAPTURE;<br />
MEASUREMENTS OF GAMMA RAY SPECTRA IN THERMAL AND<br />
2:95 KEV REGIONS DESIRABLE FOR DECISION ABOUT<br />
EXISTENCE OF INTERFERENCE EFFECTSo<br />
DIRECT MEASUREMENT OF THE EFFECTIVE RESONANCE<br />
INTEGRAL IN THE SODIUM MEDIUM FROM 24 KEV<br />
NEUTRON SOURCE SEEMS TO BE USEFUL FOR DECIDING<br />
THE QUESTION ABOUT THE 2o9 KEV RESONANCE<br />
CAPTURE WIDTH;<br />
ACCURACY REQUIRED TO BETTER THAN 1Oo PERCENTo<br />
FOR CALCULATION OF NA ACTIVATION IN LMFBRo<br />
SEE ALSO GENERAL COMMENTS IN THE INTRODUCTION<br />
SUBSTANTIAL MOD IFICATI ON So<br />
zsioie lo CO KEV 20O CX Po B, HEMMIG<br />
CoEcCLIFFOPD<br />
ATC<br />
OPL<br />
A: ACCURACY OF C,5 MB OR 20 PERCENT WANTEDo<br />
M: NEW REQUEST;<br />
Z54C17 5o 00 KEv 19o 0 MEV 1 CCP LcN,USACHEV FEI<br />
A: FROM 0 c 5 - ICO KEV ACCURACY 44 PERCENT,<br />
PRIORITY 2 ACCURACY 44 PERCENTo<br />
FROM Oo1 - Oo 8 MEV ACCURACY 50 PERCENT,<br />
PRIORITY 2 ACCURACY 50 PERCENTc<br />
FROM O08 - 4;5 MEV ACCURACY 50 PERCENT,<br />
PRIORITY 2 ACCURACY 50 PERCENT,<br />
ABOVE 4o 5 MEV REQUIREMENTS 2 TIMES WEAKERo<br />
O: NEED FOR FAST REACTOR CALCULATIONS;<br />
FOR MORE DETAIL SEE INTRODUCTION<br />
M: NEW REQUEST;<br />
STA TUS<br />
STATUS<br />
BUC PLOS TINARU+ - SCF 25 387(1973). <strong>DATA</strong> 0 92 TO 4 MEVo<br />
N PL. RYVES+ - 71 CANT 139, THERMAL;<br />
AUA CLAYTON - AUJ 23 823( 1970), FITS TOTAL SIGMA NEAR 2C 85 KEV WITH CAPTURE WIDTH OF 0 36 EVc<br />
RPI YAMA MURO + - NSE 41 445(1 970),<br />
c INOS CAPTURE WIDTH IS ;47 EV AT 2,85 KEVc<br />
, RP I HOCKENB URY + - PR * 78 17*6(1 969) , FZNCS CAPTURE WIDTH OF ,4S EV AT 20 65 KEV;<br />
GA FR IESENHAHN4- - 66WASH 2 69=, FINDS CAPTURE WIDTH OF 0;34 EV AT 2: 85 KEV:<br />
COL RAHNt - USN<strong>DC</strong>-3 66(1972), WCRK I IN FRCGRESSo<br />
ORL ALLEN - WORK IK FROGRESSo<br />
USA USN<strong>DC</strong>o (15 74), 2o8 KEVo CAPTURE WIDTH DISCREPANCY REMAINSo<br />
11 SODIUM 23 NEUTRON CAPTURE GAMMA R AY_SPECTRUM<br />
Z 2.1032 2o 95 KEV 1 Co OX 1 USA Cc E; T ILL ANL<br />
STATUS<br />
STATUS<br />
ANL JACKSON - FILE SHI ELDED-TA FGET MEASUREMENT IN PROGRESS;<br />
11 SODIUM 23 NEUTRON TOTAL PHOTON PRODUCTION CROSS <strong>SEC</strong>TION<br />
ZJ101E 2c00 ME V 1 5o 0 MEV Po Be HEMMIG<br />
CcEc CLIFFORD<br />
AEC<br />
ORL<br />
O: ENERGY AND ANGULAR DISTRIBUTION OF PHOTONS WANTEOo<br />
A: 2C PERCENT IN ANGULAR DISTRIBUTION IF NOT<br />
ISOTROPICc<br />
GAMMA ENERGY RESOLUTION 10 PERCENTo<br />
M: NEW REQUEST;<br />
11 SODIUM 22 NEUTRON<br />
Z41020 I60O MEV PcB;HEMM I G<br />
O: NEEDED FOR COOLANT ACTIVATIONc<br />
M: NEW REQUEST,<br />
11 SODIUM 23 RESONANCE PARAMETERS<br />
6Z-120E<br />
2o 95<br />
KEV<br />
CoEcTILL<br />
PcBcHEMMIG<br />
ANL<br />
AEC<br />
Q: NEUTRON AND CAPTURE WIDTH NEEDEDo<br />
Z14301<br />
2o 90<br />
KEV<br />
M0N0NIKOLAEV<br />
FEI<br />
O: NEUTRON AND CAPTURE WIDTHS WANTEDo<br />
A: NEUTRON WIDTH FOR 2c 95 KEV LEVEL WANTED WI<br />
5 PERCENT ACCURACY,<br />
ALL OTHER WIDTHS REQUIRED WITH 10 PERCENT<br />
AC CURAC Yo<br />
O: FOR FAST REACTOR CALCULATION<br />
FISSION LIST PAGE IIo 11