29.12.2013 Views

oxiperm® 164 d for 5 to 10 g/h

oxiperm® 164 d for 5 to 10 g/h

oxiperm® 164 d for 5 to 10 g/h

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GRUNDFOS alldos<br />

product in<strong>for</strong>mation<br />

Oxiperm® <strong>164</strong> D <strong>for</strong> 5 <strong>to</strong> <strong>10</strong> g/h<br />

Preparation of chlorine dioxide from diluted solutions


Measurements<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Measurements<br />

Standard system<br />

DN20<br />

40<br />

700<br />

650<br />

Ø 9<br />

230<br />

148<br />

970<br />

930<br />

90<br />

DN20<br />

148<br />

4<strong>10</strong><br />

NaClO 2<br />

HCl<br />

System <strong>for</strong> batch operation<br />

800<br />

740<br />

Ø11<br />

260<br />

1300<br />

1260<br />

90<br />

178<br />

ca. 440<br />

NaClO 2<br />

HCl


Measurements<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Measurements<br />

Front installation system <strong>164</strong>-xxxDFI<br />

900<br />

800<br />

850<br />

750<br />

DN20<br />

90<br />

NaClO 2<br />

DN<br />

20<br />

90<br />

Ø <strong>10</strong><br />

HCl<br />

<strong>10</strong>2<br />

213<br />

Types<br />

ClO 2<br />

preparation<br />

capacity<br />

p max<br />

Consumption of<br />

components<br />

Consumption of bypass water [l/h]<br />

(input pressure < p max<br />

)<br />

Weight<br />

[bar] [l/h] continuous batch operation *)<br />

operation<br />

[g/h] 50 Hz 60 Hz HCl NaClO 2<br />

0.5 g/l 1 g/l 2 g/l [kg] Measurements in mm<br />

5 7 7 0.12 420 9.9 5.8 - 35 <strong>164</strong>-005D (DFI)<br />

<strong>10</strong> 7 6 0.24 420 19.8 9.6 4.6 35 <strong>164</strong>-0<strong>10</strong>D (DFI)<br />

*) In batch operation the concentration is freely adjustable between 0.5 and 1 g/l (<strong>164</strong>-005D) and 0.5 <strong>to</strong> 2 g/l (<strong>164</strong>-0<strong>10</strong>D).<br />

These systems are also available as front installation variants. Their designation is <strong>164</strong>-xxxDFI.<br />

Type


Technical data<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Technical data<br />

Adjustment of the preparation capacity<br />

Manual by menu-controlled opera<strong>to</strong>r prompting,<br />

au<strong>to</strong>matic by input signals<br />

Protection level • IP 65 electronics, dosing pumps, solenoid valve (option), flowmeter<br />

• IP 44<br />

• IP 67<br />

bypass pump (option)<br />

dosing controller<br />

Admissible concentration of chemicals • HCl 9 percent by weight<br />

Admissible<br />

• ambient temperature<br />

• operation water temperature<br />

• chemicals temperature<br />

Admissible relative air humidity<br />

Connection dilution water inlet<br />

Connection ClO 2<br />

solution<br />

Safety equipment<br />

• NaClO 2<br />

5 <strong>to</strong> 40 °C<br />

2 <strong>to</strong> 30 °C<br />

2 <strong>to</strong> 30 °C<br />

7.5 percent by weight<br />

max. 80 % at 40 °C, not condensing<br />

PVC pipe DN 20 / option: 3/4” NPT male thread<br />

PVC pipe DN 20 / option: 3/4” NPT male thread<br />

• Parallel moni<strong>to</strong>ring of capacity via dosing controller and internal Hall sensor signal<br />

<strong>for</strong> all dosing pumps<br />

Material Supporting rack PP<br />

Mounting parts stainless steel<br />

Reac<strong>to</strong>r<br />

grey PVC, lacquered stainless steel<br />

Post mixer<br />

grey PVC<br />

Pipes<br />

grey PVC<br />

Gaskets<br />

FPM/PTFE


Data<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Electrical and electronic data<br />

• Mains voltage 230 V / 50 Hz or 115 V / 60 Hz<br />

• Control: PLC<br />

• 4-line plain text display<br />

• Menu-controlled opera<strong>to</strong>r prompting<br />

• Flow-scheme with LED display showing mode and error signal<br />

Power consumption<br />

Analog inputs<br />

300 VA<br />

0(4) - 20 mA input or free configuration, max. 50 Ohm<br />

Digital inputs • Contact water meter, 1 <strong>to</strong> 45 pulses/sec. <strong>for</strong> control *)<br />

• MIN contact <strong>for</strong> main water<br />

• Remote On/Off<br />

• Error gas warning unit<br />

Analog outputs<br />

0(4) - 20 mA isolated output or free configuration, max. loop resistance 500 Ohm<br />

Potential-free outputs<br />

• Error messages<br />

• Pre-alert: chemicals empty<br />

• Au<strong>to</strong>matic/manual operation, max. charge 250 V, 6 A, max. 550 VA<br />

*) Note: The water meter has <strong>to</strong> be designed in a way that the number of input pulses <strong>for</strong> the control is between 1 - 45 pulses/sec.<br />

Versions<br />

• Bypass line with 3-way ball valve <strong>for</strong> manual reac<strong>to</strong>r rinsing<br />

Check valve (reac<strong>to</strong>r)<br />

• System backpressure less than 3 bars<br />

• System backpressure more than 3 bars<br />

Preparation system completely <strong>for</strong> wall mounting<br />

Options<br />

• With solenoid valve, with / without exhaust system<br />

• For batch operation, with / without exhaust system<br />

• With internal bypass pump, with / without exhaust system<br />

• With external centrifugal pump (provided by the cus<strong>to</strong>mer), with / without exhaust system<br />

Bus system<br />

• Modbus (RS 232 / RS 485)<br />

• Profibus DP module (on request)<br />

• Ethernet TCP/IP module (on request)<br />

Operating languages<br />

Standard: German<br />

Other languages can be selected with the software:<br />

• English, French, Spanish, Italian


Accessories<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Suction line systems<br />

• 2 suction lines with 2 tank covers<br />

• with empty signal and pre-alert<br />

Tank size Ø Tank opening Suction line<br />

30 l 45-46 mm 1.3 m, 2.5 m, 5 m<br />

60 l 45-46 / 57-58,5 mm 1.3 m, 2.5 m, 5 m<br />

Water extraction<br />

• Material: PVC<br />

Oxiperm version Connection Order<br />

system water supply<br />

number<br />

with solenoid valve/<br />

with bypass pump<br />

DN 20 G 1“ 521-<strong>164</strong>.2<br />

Batch operation DN 15 G 3/4“ 521-<strong>164</strong>.1<br />

Injection unit<br />

• Material: PVC<br />

Oxiperm version Connection Order<br />

system inject. unit<br />

number<br />

with solenoid valve/<br />

with bypass pump<br />

DN 20 R 1“ 522-232<br />

Batch operation DN 4/8/<strong>10</strong> R 3/4“ 522-<strong>164</strong>.1<br />

Spare parts sets<br />

<strong>for</strong> Oxiperm ®<br />

System pressure<br />

less than 3 bar more than 3 bar<br />

<strong>164</strong>-005D 553-688 553-688.1<br />

<strong>164</strong>-0<strong>10</strong>D 553-688 553-688.1


Installation drawings<br />

Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />

Oxiperm® <strong>164</strong> C<br />

with solenoid valve<br />

Oxiperm® <strong>164</strong> C<br />

with internal bypass pump<br />

8<br />

12<br />

7<br />

11<br />

3<br />

6<br />

12<br />

7<br />

3<br />

6<br />

9<br />

1<br />

1<br />

<strong>10</strong><br />

2<br />

<strong>10</strong><br />

2<br />

9<br />

5<br />

4<br />

5<br />

4<br />

NaClO<br />

2<br />

HCl<br />

NaClO<br />

2<br />

HCl<br />

Oxiperm® <strong>164</strong> C<br />

batch operation<br />

5<br />

1<br />

<strong>10</strong><br />

4<br />

9<br />

2<br />

1 Oxiperm® <strong>164</strong> D electronics<br />

2 Connection <strong>for</strong> bypass water input<br />

3 Connection <strong>for</strong> the ClO 2<br />

solution line output <strong>to</strong> the injection unit<br />

4 Suction line <strong>for</strong> the HCl dosing pump<br />

5 Suction line <strong>for</strong> NaClO 2<br />

dosing pump<br />

6 Shutt-off valve (by cus<strong>to</strong>mer)<br />

7 Sample extraction (by cus<strong>to</strong>mer)<br />

8 Check valve (by cus<strong>to</strong>mer),<br />

<strong>for</strong> operation with an internal bypass pump<br />

9 Shut-off valve <strong>for</strong> bypass water extraction (by cus<strong>to</strong>mer)<br />

<strong>10</strong> Exhaust system <strong>for</strong> supporting rack (option)<br />

11 Pressure loading valves (by cus<strong>to</strong>mer) <strong>for</strong> system backpressures<br />

< 1 bar<br />

12 Inductive flowmeter 4-20 mA or contact water meter <strong>for</strong> proportional<br />

control of the system<br />

Note:<br />

For protection of the drinking water supply, the cus<strong>to</strong>mer has <strong>to</strong><br />

provide a pipe disconnec<strong>to</strong>r (<strong>to</strong> DVGW, W624).<br />

NaClO 2<br />

HCl


Being responsible is our foundation<br />

Thinking ahead makes it possible<br />

Innovation is the essence<br />

91836411 0<strong>10</strong>8<br />

15.8<strong>10</strong>039 V7.0<br />

EN<br />

Subject <strong>to</strong> change<br />

© Grundfos Alldos<br />

Dosing & Disinfection<br />

ALLDOS Eichler GmbH<br />

www.grundfosalldos.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!