- Page 1 and 2:
TRAINING 2007/2008 DESA Poland Sp.
- Page 3 and 4:
ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 5 and 6:
DESA POLAND ul. Magazynowa 5A, 62-0
- Page 7 and 8:
Electric heaters - assembling lines
- Page 9 and 10:
STRATEGY THE COMPANY WANTS TO DEVEL
- Page 11 and 12:
FUEL CHARACTERISTICS SOURCES OF ENE
- Page 13 and 14:
HEATERS SELECTION k = 3,0 - 4,0 woo
- Page 15 and 16:
ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 17 and 18:
Temperature range after blend fans
- Page 19 and 20:
Desa Poland warehouse ul. Magazynow
- Page 21 and 22:
Calculation of heat capacity for De
- Page 23 and 24:
CONDITION 1 Minimum oxygen in the a
- Page 25 and 26:
DIRECT FIRED HEATERS LOW PRESSURE M
- Page 27 and 28:
LOW PRESSURE DIRECT HEATERS ul. Mag
- Page 29 and 30:
DIRECT HEATERS ul. Magazynowa 5A, 6
- Page 31 and 32:
Characteristic and advantages: ‣
- Page 33 and 34:
ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 35 and 36:
Application : ‣Agriculture, indus
- Page 37 and 38:
INDIRECT FIRED HEATERS Model Capaci
- Page 39 and 40: ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 41 and 42: ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 43: ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 46 and 47: Comparison BV (old and new) New Old
- Page 48 and 49: Gauge fuel level new old Bigger whe
- Page 50 and 51: 14 mm Other size regulation of comb
- Page 52 and 53: Chickencoops - chickens, ducks, gee
- Page 54 and 55: VENTED OIL HEATERS Model CAPACITY [
- Page 56 and 57: OPERATION AND CONSTRUCTION BV 300 ,
- Page 58 and 59: CONTROL BOARD 1 CONTROL LAMP 2 CONT
- Page 60 and 61: GREEN Model Capacity Air displaceme
- Page 62 and 63: Characteristics: Separate oil burn
- Page 64 and 65: CABINET OIL HEATERS BF TYPES Model
- Page 66 and 67: CONSTRUCTION 1. MAIN CONTROL KNOB 2
- Page 68 and 69: BG 100 BG 150 BG 200 Model Capacity
- Page 70 and 71: BI 350 BI 500 ul. Magazynowa 5A, 62
- Page 72 and 73: ACCESSORIES FOR BI PROTECTION HOOD
- Page 74 and 75: Fuel tank installation in BVS and B
- Page 76 and 77: If the fuel tank is placed higher t
- Page 78 and 79: Thermostats 4150.105 BLP 30/50/70/1
- Page 80 and 81: Flue pipes instalation chimney roof
- Page 82 and 83: code description suitable for model
- Page 84 and 85: chimney roof passage elbow adjustab
- Page 86 and 87: tee stalflex connector ul. Magazyno
- Page 88 and 89: Comparison of heating systems - Hea
- Page 92 and 93: -XL 9 E-S -workers ul. Magazynowa 5
- Page 94 and 95: UNIVERSAL OIL HEATERS WA 29 WA 41 W
- Page 96 and 97: Application : industry - heating a
- Page 98 and 99: GAS HEATERS BLP 15 M BLP 30 M BL
- Page 100 and 101: OPERATION ul. Magazynowa 5A, 62-023
- Page 102 and 103: Securities : Electromagnetic valve
- Page 104 and 105: Why do we use gas heaters !?! Metha
- Page 106 and 107: Coupling set to gas heaters Connect
- Page 108 and 109: Model B 2 EPA B 3 SEPA B 3,3 EPA B
- Page 110 and 111: Axial-flow fan sucks the air from t
- Page 112 and 113: B 15 EPA i B 22 EPA FRONT BACK ul.
- Page 114 and 115: INFRARED ELECTRIC HEATERS HALL 3000
- Page 116 and 117: Infrared electric and fan electric
- Page 118 and 119: ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 120 and 121: Model Capacity l/24h 80% (30°C) Ai
- Page 122 and 123: Defrosting via air flow and thermoe
- Page 124 and 125: DH 41 has fixing screw of air filte
- Page 126 and 127: Model Capacity l/24h 80% (30°C) Ai
- Page 128 and 129: Application : • Basements, stocks
- Page 130 and 131: Dehumidifiers Humidity increment in
- Page 132 and 133: Water tank: W 2 = σ × A × (x”
- Page 134 and 135: Required dehumidifier capacity W =
- Page 136 and 137: ul. Magazynowa 5A, 62-023 GĄDKI, t
- Page 138 and 139: DH-711 35 30 4,8 5,5 6,5 8,0 10,0 2
- Page 140 and 141:
Comparison Master-Sial GRYP BV 70 u
- Page 142 and 143:
BV 70 Sial GRYP 15 High pressure bu
- Page 144 and 145:
BLP 30 M vs GRISOU 25 Master has al
- Page 146 and 147:
Master has additional protection on
- Page 148 and 149:
Master has better quality of weldin
- Page 150 and 151:
Master has extra metal frame for fi
- Page 152 and 153:
Master has only one cover, Grisou h
- Page 154 and 155:
Master has additional nuts on gas c
- Page 156 and 157:
Master has plastic handle mounted o
- Page 158 and 159:
Master has simpler costruction of g
- Page 160 and 161:
Master do not use rivets for fixing
- Page 162 and 163:
B 150 CED vs MIZAR 15 Master doesn
- Page 164 and 165:
Master has less complicated solutio
- Page 166 and 167:
Master has more practical solution
- Page 168 and 169:
Master has more space inside heater
- Page 170 and 171:
View of air pumps after put-off fan
- Page 172 and 173:
Master doesn’t have a pc board -
- Page 174 and 175:
Master has better quality of perfor
- Page 176 and 177:
Comparison BV 170 vs SIAL MIRAGE 55
- Page 178 and 179:
300 mm 250 mm Master has bigger whe
- Page 180 and 181:
Master has fuel level probe ul. Mag
- Page 182 and 183:
Master has fuel pump outside heater
- Page 184 and 185:
Master has shelf for electric compo
- Page 186 and 187:
Covers in Master connect on screws
- Page 188 and 189:
Master has handles at the higher pa
- Page 190 and 191:
Master has handle for power cord ul
- Page 192 and 193:
Master has inclinated down-back sid
- Page 194 and 195:
Inclinated tank for easy refueling
- Page 196 and 197:
Warranty time for spare parts GROUP
- Page 198 and 199:
PLASTIC AND RUBBER ELEMENTS handles
- Page 200 and 201:
REPAIRS UNDER THE GUARANTEE DO NOT
- Page 202:
THANK YOU FOR YOUR ATTENTION ul. Ma