05.01.2014 Views

Door Handles, Locking and Security - Hafele

Door Handles, Locking and Security - Hafele

Door Handles, Locking and Security - Hafele

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Architectural Hardware<br />

<strong>Locking</strong> <strong>and</strong> <strong>Security</strong><br />

Master key system information<br />

Where two or more individual cylinders are not only locked by an individual key, but also by superior keys, a so-called master key system is<br />

created. The application of master key systems reaches i. e. from apartment blocks to office complexes. Häfele supplies master key systems in<br />

all sizes for any type of cylinder, on request also with patented key profiles as well as with many special features. Many customers asked for<br />

master key systems made in Germany but criticize the long delivery times which you have with made goods from Germany. For this reason<br />

Häfele Thail<strong>and</strong> developed their own master key system production. Our master key systems SD <strong>and</strong> PSM are completely produced in Germany<br />

<strong>and</strong> only the last steps of to cut the key are done in Thail<strong>and</strong>. With this service Häfele Thail<strong>and</strong> is able to offer their customer master key<br />

systems with German quality in short delivery times. However, the Häfele service not only comprises the delivery. Häfele has experts for hardware<br />

technology, master key systems <strong>and</strong> for any questions relating to individual cylinders. The service reaches from initial assistance in the<br />

planning phase to the creation of appropriate master key plans.<br />

Differences are made between the following master key systems:<br />

MK<br />

MK-System (Master Key System)<br />

Example: Buildings with four store rooms<br />

Each master key cylinder can be locked with the master<br />

key as well as the individual key allocated to it.<br />

S S S S<br />

Area of operation<br />

Master key /<br />

Managing Director<br />

S<br />

MK<br />

Store room<br />

Master key<br />

Key No.<br />

MK<br />

1 – 4 Individual key store rooms<br />

<strong>Door</strong> or room<br />

Cyl. <strong>and</strong><br />

key No.<br />

Number of<br />

cylinders<br />

Cat.<br />

No.<br />

Length A<br />

Length B<br />

Number<br />

of keys<br />

5<br />

Store 1 1 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Store 2 2 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Store 3 3 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Store 4 4 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Superior keys ><br />

GMK-System (Gr<strong>and</strong> Master Key System)<br />

Example: office Buildings<br />

Each master key cylinder can be locked with the master<br />

key as well as the individual key allocated to it.<br />

P<br />

Plant room<br />

E<br />

EDP<br />

We reserve the right to alter specifications without notice (HMA Basic 2011/12).<br />

GMK Gr<strong>and</strong> master key<br />

MK Master key<br />

SMK Sub master key<br />

1 – 5 Plant room, EDP room<br />

6 – 10 General master key<br />

<strong>Door</strong> or room<br />

Cyl. <strong>and</strong><br />

key No.<br />

Number of<br />

cylinders<br />

Cat.<br />

No.<br />

Length A<br />

Length B<br />

Number<br />

of keys<br />

Plant room 1 1 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Plant room 2 2 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Plant room 3 3 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Plant room 4 4 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Plant room 5 5 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

EDP 6 6 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

EDP 7 7 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

EDP 8 8 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

EDP 9 9 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

EDP 10 10 1 916l ..l ... 31.5 mm 31.5 mm 3<br />

Area of operation<br />

Key No.<br />

Superior keys ><br />

Managing Director / Fire brigade<br />

Plant manager<br />

Departmental manager EDP<br />

Plant office manager<br />

Plant sales department<br />

Office manager EDP<br />

Sales department EDP<br />

GMK<br />

MK1<br />

MK2<br />

SMK1<br />

SMK2<br />

SMK3<br />

SMK4<br />

5<br />

3<br />

3<br />

2<br />

2<br />

2<br />

2<br />

10<br />

New products <strong>and</strong> systems: www.hafele.com<br />

HMA 10.47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!