CVM<br />

<strong>CanVent</strong> <strong>Ductless</strong> <strong>Ventilation</strong> <strong>System</strong><br />

20/CVM/XXXX/0107/EN<br />

© <strong>Halton</strong><br />

• Adjustable leveling legs enables install on uneven<br />

floors.<br />

• Available in four (4) convenient sizes.<br />

• Modular design allows for quick and easy wash<br />

down of all air screen components.<br />

• Front accessible for easy service with standard<br />

off-the-shelf components.<br />

<strong>Application</strong><br />

The CVM (<strong>CanVent</strong>) model is a freestanding self-contained<br />

system, providing additional fryer, grills or charbroiler capacity<br />

within limited kitchen space. The CVM (<strong>CanVent</strong>) requires no<br />

additional ducting. It is a stand alone unit which gives the<br />

flexibility of location and ease of installation. For use with<br />

electrical equipment only.<br />

• Uses standard readily-available hospital grade filters<br />

for higher air quality, longer filter life and reduces<br />

costs.<br />

• Simple start and stop switches control operation and<br />

monitor for proper performance and safety.<br />

• Front air bar draws fumes and odors into a unique<br />

front air screen, locking it into the dynamicallydesigned<br />

highly efficient hood for easy cleaning.<br />

CVM - <strong>CanVent</strong> <strong>Ductless</strong> <strong>Ventilation</strong> <strong>System</strong><br />

1


Specification Information<br />

The hood capture area shall be stainless steel. Shaped<br />

interior surface directs fumes and odor toward exhaust.<br />

Outer end panels, filter module housing and top of unit to<br />

be painted white. Filter housing material shall be 16 gauge<br />

galvanized steel. Furnish with high efficiency stainless<br />

steel Quest Fireguard grease extractors. Extractors<br />

provided with handles for ease of removal and cleaning.<br />

Modular fan and filter housing provided with bolted access<br />

doors. <strong>System</strong> comes complete with a non-overloading<br />

impeller fan capable of handling static pressure from<br />

2.0” to 7.0”. Integral safety pressure differential switches<br />

incorporated to ensure system cannot operate when filters<br />

are loaded.<br />

20/CVM/XXXX/0107/EN<br />

Furnish and install a complete ductless kitchen hood<br />

system. The system shall be the <strong>CanVent</strong> model<br />

CVM________ as manufactured by <strong>Halton</strong>. The system<br />

shall bear the label of ETL as tested according to U.L.<br />

710 and meet the requirement of NFPA 96 and bear<br />

the label of the National Sanitation Foundation seal of<br />

approval.<br />

The installation shall be in accordance with the<br />

manufacturer’s recommendations and conform to NFPA<br />

96 guidelines and all applicable local codes. The size<br />

shall be as indicated on the drawings and/or equipment<br />

schedule.<br />

Filter housing comes with Class 1 pleated prefilter, 90-<br />

95% efficient Mini-Pleat secondary filter, and 99% HEPA<br />

filter. Refillable activated charcoal cell is provided for the<br />

elimination of odor. No chemical masking shall be used.<br />

Air bar is provided to contain heat and effluents within the<br />

hood capture area. Bar shall be removable for maintenance<br />

and cleaning of appliances.<br />

<strong>System</strong> comes with adjustable leveling legs.<br />

All operating components and filters shall be easily<br />

accessible through front access panels.<br />

Start/Stop pushbuttons control operation.<br />

CVM - <strong>CanVent</strong> <strong>Ductless</strong> <strong>Ventilation</strong> <strong>System</strong><br />

2


A<br />

48"<br />

(1219)<br />

ELECTRICAL<br />

FAN<br />

C<br />

2" FIRE<br />

DAMPER<br />

8" CHARCOAL<br />

FILTER<br />

AIR BAR<br />

A<br />

5" (127)<br />

GREASE<br />

CUP<br />

B<br />

30"LX4"W OUTLET<br />

COOKING<br />

EQUIPMENT<br />

12" HEPA<br />

FILTER<br />

4" MESH<br />

FILTER<br />

2" PAPER<br />

FILTER<br />

48"<br />

(1219)<br />

Dimensions<br />

MODEL<br />

A B C<br />

A<br />

in mm in mm in mm<br />

CVM 45 C 58.5 1486 54 1372 22 559<br />

CVM 65 82.5 2096 78 1981 22 559<br />

CVM 80 100.5 2553<br />

5" (127)<br />

96 2438 22 559<br />

CVM 100 121.75 3092 117.25 2978 22 559<br />

30"LX4"W OUTLET<br />

20/CVM/XXXX/0107/EN<br />

Top View<br />

A<br />

ELECTRICAL<br />

34"<br />

(864)<br />

FAN<br />

8" CHARCOAL<br />

FILTER<br />

4" MESH<br />

FILTER<br />

A<br />

ELECTRICAL<br />

ELECTRICAL<br />

8" CHARCOAL<br />

FILTER<br />

4" MESH<br />

FILTER<br />

FAN<br />

2" FIRE<br />

DAMPER<br />

12" HEPA<br />

FILTER<br />

2" PAPER<br />

FILTER<br />

97"<br />

(2464)<br />

GREASE<br />

FILTERS<br />

B<br />

AIR BAR<br />

COOKING<br />

EQUIPMENT<br />

GREASE<br />

CUP<br />

REMOVABLE<br />

AIR BAR<br />

67"<br />

(1702)<br />

2" FIRE<br />

DAMPER<br />

B<br />

AIR BAR<br />

12" HEPA<br />

FILTER<br />

2" PAPER<br />

FILTER<br />

GREASE<br />

CUP<br />

COOKING<br />

EQUIPMENT<br />

33"<br />

(838)<br />

COOKING<br />

EQUIPMENT<br />

34"<br />

(864)<br />

48"<br />

(1219)<br />

Side View<br />

ELECTRICAL<br />

Front View<br />

34"<br />

(864)<br />

CVM - <strong>CanVent</strong> <strong>Ductless</strong> <strong>Ventilation</strong> <strong>System</strong><br />

3<br />

ELECTRICAL<br />

GREASE