Steam Extraction Canopy<br />

KVV/1303/UK<br />

WWW<br />

ALLIED MEMBER<br />

• Condensation is achieved by the use of angled<br />

internal baffles and deflectors<br />

• Efficient exhaust is maintained by using lateral side<br />

slots combined with the large internal volume<br />

• Modular construction simplifies design and<br />

installation<br />

• Adjustment and measurement of airflow using the<br />

T.A.B. measuring tap in combination with an<br />

adjustment damper within the extract spigot(s)<br />

• Manufactured from polished stainless steel AISI 304<br />

• Surface mounted light fittings are available as an<br />

accessory.<br />

The KVV steam extraction canopy has been especially<br />

adapted to capture, condense and remove steam<br />

produced by industrial dishwashers, cooking pots and<br />

other appliances with low grease emission level. In<br />

general KVV canopy is well suited for applications,<br />

where grease filtration is not the main requirement.<br />

KVV - Steam Extraction Canopy<br />

1


KVV DESCRIPTION<br />

KVV/1303/UK<br />

6<br />

1<br />

5<br />

7<br />

5<br />

2 2<br />

3<br />

4<br />

Function<br />

The canopy above the steam producing equipment<br />

contains large volumes of humid air, which are<br />

exhausted via the upper baffle chicane (1).<br />

Two lateral side slots (2) prevent the condensed water<br />

from dripping down on to the work surfaces.<br />

CODE DESCRIPTION<br />

1 Upper baffle chicane<br />

2 Lateral slots<br />

3 Outer casing / condense channel<br />

4 Collection tray or drain tap<br />

5 Interior baffles<br />

6 Exhaust air connection and damper plate<br />

7 Measurement tap TAB<br />

Construction<br />

The outer casing (3) is manufactured from easy-toclean<br />

stainless steel AISI 304. The plenum top panel,<br />

connection spigots and control damper are<br />

manufactured from galvanised steel, (optionally from<br />

stainless steel AISI 304). All lower joints of the canopy<br />

are fully welded and polished to ensure water<br />

tightness. KVV canopy is equipped with a draining tap<br />

(4) for removal of collected condensates. The interior<br />

baffles (5) are removable to allow access for cleaning<br />

the inside of the exhaust plenum. Adjustment and<br />

measurement of the exhaust airflow is carried out<br />

using the adjustment damper (6) located within the<br />

exhaust duct spigot(s) and the measurement tap<br />

T.A.B. (7).<br />

An optional surface mounted light fitting is installed on<br />

the bulkhead of the canopy.<br />

Accessories<br />

• Cover Boards - where canopies are below ceiling<br />

level<br />

• Infill Panels<br />

• Surface mounted light fitting - IP65 (max. ambient<br />

temperature 35°C)<br />

• Non-standard spigots: choice of size and position<br />

• Totally stainless steel construction<br />

QUICK DATA<br />

Recommended Exhaust air volumes<br />

L l/s m 3 /h<br />

1000 305 1100<br />

1500 445 1600<br />

2000 610 2200<br />

2500 805 2900<br />

The recommended exhaust air volumes shown above provide the<br />

optimum velocity required through the slots.<br />

LpA < 45 dB(A)<br />

KVV - Steam Extraction Canopy<br />

2


DIMENSIONS<br />

KVV<br />

KVV/1303/UK<br />

1000...1900<br />

400, 555<br />

M<br />

Note: The dimensions above are for modular sections only; larger<br />

canopies are assembled using a combination of separate modules,<br />

which makes transportation and site handling easier.<br />

LOCATION OF CONNECTIONS (mm)<br />

For typical sizes<br />

L M N<br />

1000 - -<br />

1500 375 750<br />

2000 500 1000<br />

2500 500 1250<br />

3000 500 1500<br />

L/2<br />

WEIGHTS (kg)<br />

400 mm<br />

N<br />

L = 1000...3000<br />

L/B 1000 1100 1300 1500<br />

1000 43 47 50 54<br />

1500 54 57 60 64<br />

2000 69 72 76 81<br />

2500 80 83 87 93<br />

555 mm<br />

L/B 1000 1100 1300 1500<br />

315<br />

1000 49 53 56 59<br />

1500 61 63 66 69<br />

2000 75 79 84 88<br />

2500 86 91 97 101<br />

Position of Drain tap, when fitted<br />

Mounting bracket 150 mm high<br />

30 170<br />

Side view<br />

Front view<br />

KVV - Steam Extraction Canopy<br />

3


KVV/1303/UK<br />

WWW<br />

www.halton.com/foodservice<br />

France Asia Pacific<br />

Germany Middle-East<br />

India USA<br />

China Asia Pacific<br />

<strong>Halton</strong> SAS Group Asia Sdn Bhd<br />

<strong>Halton</strong> Foodservice Middle-EastGmbH<br />

<strong>Halton</strong> India Co. Pvt. Ltd.<br />

<strong>Halton</strong> <strong>Halton</strong> Ventilation Group Asia Co., Ltd Sdn Bhd<br />

Technoparc E-14, Jalan Multimedia Futura 7/AG<br />

Tiroler P.O. Box Str. 18116 60<br />

No. 101 3580 Industrial Fremont Drive Terraces<br />

浩 盾 E-14, 通 风 设 Jalan 备 ( Multimedia 上 海 ) 有 限 公 7/AG 司<br />

BP City 102 Park, i-City<br />

83242 Dubai Reit im Winkl<br />

Lower Scottsville, Ground KY Floor, 42164<br />

Block City 10,No Park, 600 i-City South Xinyuan Rd<br />

62402 40000 Béthune Shah Alam, Cedex Selangor<br />

Tel. United +49 Arab 8640 Emirates 8080<br />

4th Tel. Cross, +1 270 13th 2375600 G Main,<br />

Lingang 40000 New Shah City,Pudong Alam, Selangor<br />

Tel. Malaysia +33 (0)1 80 51 64 00<br />

Fax Tel. +49 + 971 8640 (0)480888<br />

883 7215<br />

Indiranagar, Fax + 1 2702nd 2375700 Stage<br />

Shanghai,201306<br />

Malaysia<br />

Fax Tel. +60 +33 3 (0)3 3258 21 3600 64 55 10<br />

info.de@halton.com<br />

Fax + 971 (0)4 883 7216<br />

Bangalore info@haltoncompany.com<br />

560 038<br />

The Tel. People’s +60 3 Rebublic 3258 3600 of China<br />

foodservice@halton.fr<br />

Fax +60 3 3258 3699<br />

www.halton.de<br />

sales@halton.ae<br />

Tel. www.haltoncompany.com<br />

: +91 80 4112 3697<br />

Tel.: Fax +86 +60 (0)21 3 3258 5868 3699 4388<br />

www.halton.fr<br />

sales@halton.com.my<br />

Fax: +91 80 4112 3698<br />

sales@halton.com.my<br />

Fax:+86 sales@halton.com.my<br />

(0)21 5868 4568<br />

sales@halton.com.my<br />

www.halton.com<br />

United Japan Kingdom<br />

Japan Korea representative<br />

Canada<br />

Middle-East<br />

<strong>Halton</strong> Foodservice Co. Ltd. Ltd<br />

<strong>Halton</strong> Le Meilleur Co. Ltd. Jongno Town<br />

<strong>Halton</strong> Indoor Climate<br />

<strong>Halton</strong> Middle-East<br />

11 Hatagaya Laker Road ART-II 2F<br />

Hatagaya #1829 Jongno ART-II 12F<br />

Ga,<br />

Systems, Ltd.<br />

P.O. Box 18116<br />

Airport 1-20-11 Industrial Hatagaya Estate<br />

1-20-11 Jongno-gu Hatagaya Seoul,<br />

1021 Brevik Place<br />

Dubai<br />

Rochester, Shibuya-ku Kent ME1 3QX<br />

Shibuya-ku Korea 110-888<br />

Mississauga, Ontario<br />

United Arab Emirates<br />

Tel. Tokyo +44 151-0072 1634 666 111<br />

Tokyo Tel.: +82 151-0072 2 2075 7990<br />

L4W 3R7<br />

Tel. + 971 (0)4 883 7215<br />

Fax Tel.+ +44 81 31634 6804 666 7297 333<br />

Tel.+ Fax: +82 81 326804 20757297<br />

7991<br />

Tel. + 905 624 0301<br />

Fax + 971 (0)4 883 7216<br />

foodservice@halton.co.uk<br />

Fax + 81 3 6804 7298<br />

Fax sales@halton.com.my<br />

+ 81 3 6804 7298<br />

Fax + 905 624 5547<br />

sales@halton.ae<br />

www.halton.co.uk<br />

salestech.jp@halton.com<br />

salestech.jp@halton.com<br />

info@haltoncanada.com<br />

www.halton.com<br />

www.halton.jp<br />

www.halton.jp<br />

www.haltoncanada.com<br />

The company has a policy of continuous product development, therefore we reserve the right to modify design and<br />

specifications without notice. For more information, please contact your nearest <strong>Halton</strong> agency. To find it:<br />

www.halton.com/locations<br />

KVV - Steam Extraction Canopy<br />

4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!