ISO 9001 D906/ el - en mod.P5/C1<br />
SETTING THE MAXIMUM STROKE OF THE MOTOR<br />
REDUCER WITH POTENTIOMETER P1<br />
<strong>1.</strong> Work on the ring until you obtain the maximum range of the circular potentiometer;<br />
2. Regulate potentiometer P1 to alter the stroke of the motor reducer so as to<br />
obtain maximum acceleration (the maximum stroke of the motor reducer is 5.5<br />
cm);<br />
Setting the maximum stroke of the motor<br />