ISO 9001 D906/ el - en mod.P5/C1<br />

4) Checking the electrical connection between the motor reducer, the<br />

exchange and the coil of the motor reducer’s electric motor.<br />

• Check the state of the contacts on the connector;<br />

• To check the coil of the electric motor of the motor reducer, proceed as follows:<br />

- Disconnect the electric connector of the motor reducer from the wiring, measure<br />

the resistance between the RED cable and the BLACK cable; the<br />

multiple-purpose tester should show a value of between 1 and 5 Ω.<br />

- If the multi-purpose tester shows a value of 0 Ω, there is a short-circuit on the coil.<br />

- If the resistance value shown is very high, either the coil is interrupted or the<br />

brushes have deteriorated.<br />