Cleveland<br />

<br />

COOK CHILL SYSTEMS<br />

Cook/Chill Systems<br />

Project ________________________________<br />

Item __________________________________<br />

Quantity _______________________________<br />

FCSI Section ____________________________<br />

Approval _______________________________<br />

Date __________________________________<br />

TM<br />

MODEL:<br />

TJ-100-CC<br />

COMBINATION COOK TANK, CHILLER<br />

& SOUS VIDE PRODUCTION UNIT<br />

Cleveland General Specifications<br />

The capacity of the <strong>TurboJet</strong> is up to 100 gal. for pumpable<br />

(kettle produced) products and up to 1000 lbs. of meat in the<br />

cook tank mode. The <strong>TurboJet</strong> functions as a cook tank, a<br />

product chiller and a sous vide production unit. Most pumpable<br />

food products packaged in pouches or casings can be cooled<br />

from 170°F to 40°F in an average of less than one hour.<br />

Cleveland Standard Features<br />

■ Microprocessor operating controls mounted in Type 4X<br />

housing<br />

● Power on/off switch<br />

● Time and temperature set-point controls<br />

● Two pen chart recorder<br />

● Stainless steel bag unloading tool<br />

● Three operating mode selection<br />

✓ Chill Cycle<br />

✓ Cooking/Heating cycle to time and temperature<br />

✓ Automatic cooking cycle with core temperature probe<br />

■ Low 40" loading rim height<br />

■ Tank equipped with two powerful turbo jets for water and<br />

product agitation<br />

■ All stainless steel type 304 construction<br />

■ Rounded internal tank corners for efficient cooling and<br />

easy cleaning<br />

■ Powerful 7.5 HP water circulation pump with high and low<br />

pre-set flow-rates<br />

■ 1 HP water circulation pump for even water bath<br />

temperature distribution<br />

■ High efficiency plate type heat exchanger for<br />

product cooling<br />

■ 100 PSI steam jacket for product/tank heating<br />

■ Stainless steel spring assisted hinged rear cover<br />

■ 4 legs with adjustable flanged feet for floor bolting<br />

■ Core-temperature meat probe for recording internal<br />

product temperature<br />

■ Built in chart recorder for time / temperature recording<br />

■ 20 HP remote condensing unit (specify air or water cooled)<br />

■ 190 gal. capacity heat exchange tank with automatic temperature<br />

control and 5 HP glycol circulation pump for cooling.<br />

■ Accepted for use in U.S.D.A. Inspected Facilities<br />

Short Form Specifications<br />

Shall be CLEVELAND Model: TJ-100-CC Combination Cook Tank,<br />

Product Chiller and Sous Vide Production Unit with 20 HP Remote<br />

Condensing Unit and Heat Exchange Tank, capacities; 100 gal. of<br />

casing packaged pumpable product or 700 lbs. of meat.<br />

Temperature reduction of 170°F to 40°F in less than one hour for<br />

most products, 40" loading rim height, all stainless steel type 304<br />

construction, 7.5 HP Water Circulation Pump with high/low preset<br />

flow rates, 1 HP Water Circulation Pump with tank mounted<br />

Microprocessor Operating Controls and Chart Recorder.<br />

Options & Accessories<br />

❐ One set of wire baskets with carrier for meat cooking<br />

❐ Dolly for wire basket set<br />

❐ Ice-builder Package(in lieu of glycol heat exchange package)<br />

❐ Electric Chain Hoists for product loading of cook tank items<br />

❐ Steam Boiler<br />

❐ Spare Meat Probe<br />

❐ Product Lifting Rack<br />

❐ Flow Meter for chilled water loop<br />

❐ Air Power Vacuum Clipper<br />

SECT. XIV PAGE 33<br />

0609<br />

1333 East 179 St.,<br />

Cleveland, Ohio, U.S.A. 44110<br />

Tel: 1-216-481-4900<br />

Fax: 1-216-481-3782<br />

Web Site: www.ClevelandRange.com<br />

Email: Steam@ClevelandRange.com


<strong>TurboJet</strong><br />

Tank<br />

57.0"<br />

1448<br />

41.8"<br />

1061<br />

(LEG CENTERS)<br />

BF1<br />

23.4"<br />

3 PIECE HINGED<br />

594<br />

FRONT COVER<br />

68.2"<br />

(MINIMUM CLEARANCE)<br />

1731<br />

33.0"<br />

839<br />

5.5" / 140<br />

Air Cooled<br />

Condensing Unit<br />

20 HP air cooled condensing unit (13 ton cooling<br />

capacity) for outdoor installation<br />

Note: optional water cooled condensing unit for indoor<br />

installation available<br />

108.0"<br />

2744<br />

AC1<br />

AC2<br />

AC1 AC2<br />

CONTROL CENTER<br />

& JUNCTION BOX<br />

82.0"/ 2083<br />

73.0"/ 1854<br />

63.0"/ 1600<br />

48.0"/ 1219<br />

45.0"/ 1143<br />

43.0"/ 1092<br />

37.0"/ 940<br />

23.0"<br />

584<br />

15.0"<br />

381<br />

12.0"<br />

305<br />

CR<br />

BF2<br />

57.5"/ 1461 (LEG CENTERS)<br />

88.5"/ 2248<br />

LIFTING AREA<br />

FOR FORK TRUCK<br />

42.0"<br />

1067<br />

52.0"<br />

1321<br />

DC<br />

D1<br />

SF<br />

22.3"<br />

565<br />

Minimum Clearance<br />

15.0"<br />

381<br />

BACK - 42.0"/ 1067<br />

FRONT - 24.0"/ 610<br />

LEFT - 24.0"/ 610<br />

RIGHT - 36.0"/ 915<br />

CONDENSING UNIT POWER<br />

208/3/60 - Min. Circuit<br />

Amps (MOC) - 95A with<br />

Maximum Over Current<br />

Protection (MOCP) 125 Amp<br />

Fused Disconnect<br />

460/3/60 - Minimum Circuit<br />

Amps (MOC) - 45A with<br />

Maximum Over Current<br />

Protection (MOCP) 60 Amp<br />

Fused Disconnect<br />

AC1 2" NPT GLYCOL TO<br />

ON TURBOJET AND CR2<br />

ON HEAT EXCHANGE TANK<br />

AC2 2" NPT GLYCOL FROM CR3<br />

ON HEAT EXCHANGE TANK<br />

BACK - 12.0" LEFT - 6.0" RIGHT - 36.0"<br />

305 153 914<br />

NOTE: OPTIONAL HOIST AVAILABLE (HIGHLY<br />

RECOMMENDED) FOR LOADING<br />

COOK TANK BASKETS<br />

CR<br />

D1<br />

DC<br />

SF<br />

BF1<br />

Utility Connections<br />

1" NPT STEAM IN (420 lbs./191 kg. per hour required, 60-80 PSI steam pressure recommended)<br />

1" NPT COLD POTABLE WATER IN (30 gal./114 litres per minute)<br />

1 1/2" NPT COOLING WATER OR GLYCOL IN (flow rate is 40 gal./152 litres per minute)<br />

3/4" NPT CONDENSATE RETURN<br />

1 1/2" NPT COOLING WATER OR GLYCOL RETURN<br />

MAIN POWER IN (208V/3PH/60hz - FLRA 45 Amps)<br />

1 1/2" NPT TANK DRAIN TO FLOOR DRAIN<br />

1/2" NPT COOLING DRAIN WATER TO FLOOR DRAIN<br />

1" NPT STRAINER FLUSH TO FLOOR DRAIN<br />

1" NPT BACKFLUSH WATER IN (25 gal./95 litres per minute, 165°F/75°C hot water min.)<br />

BF2 1" NPT BACKFLUSH WATER OUT TO FLOOR DRAIN<br />

NOTE: The pressure drop is 12 to 15 PSI for steam and chilled water passing through the <strong>TurboJet</strong>.<br />

0.6"<br />

16 4.0"<br />

102<br />

FLANGED FOOT<br />

DETAIL<br />

Minimum Clearance<br />

CONTROL BOX<br />

CHART<br />

RECORDER<br />

24.0"<br />

610<br />

Heat Exchange Tank<br />

JUNCTION<br />

BOX<br />

CR3<br />

0.8" / 19<br />

HOLE IN<br />

EACH FOOT<br />

PLUMBING LINES<br />

SHOWN ROTATED<br />

FOR CLARITY<br />

DIMENSIONS<br />

INCHES"<br />

MILLIMETERS<br />

SHIPPING WEIGHTS<br />

<strong>TurboJet</strong> Chiller : 1,700 lbs. (772 kg.)<br />

Condensing Unit : 1,600 lbs. (726 kg.)<br />

Heat Exchange Package : 450 lbs. (205 kg.)<br />

CR2<br />

CR1<br />

CR1<br />

CR2<br />

CR3<br />

NOTE:<br />

9.0"<br />

229<br />

PLUMBING<br />

CONNECTIONS<br />

HEIGHT<br />

40.5"<br />

1029<br />

Minimum Clearance<br />

(for cooling) BACK - 6.0"/ 153<br />

58.0"<br />

FRONT - 20.0"/ 508<br />

1472<br />

LEFT - 20.0"/ 508<br />

RIGHT - 6.0"/ 153<br />

28.0"<br />

712<br />

10.5"<br />

267<br />

10.0"<br />

254<br />

16.0"<br />

407<br />

8.0"<br />

202<br />

53.5"<br />

1359<br />

56.0"<br />

1447<br />

41.0"<br />

1042 4.7"<br />

CR3<br />

CR1 118<br />

CR2<br />

5.7"<br />

143<br />

37.7"<br />

958<br />

18.0"<br />

558<br />

68.9"<br />

1750<br />

PUMP MOTOR POWER IN<br />

(208V/3PH/60hz, 18 Amps)<br />

CONTROL POWER IN<br />

(120V/1PH/60hz, 3 Amps)<br />

1 1/2" NPT GLYCOL FROM<br />

ON TURBOJET<br />

1 1/2" NPT GLYCOL FROM<br />

AC1 ON CONDENSING UNIT<br />

1 1/2" NPT GLYCOL OUT TO<br />

AC2 ON CONDENSING UNIT<br />

GLYCOL SOLUTION NOT<br />

SUPPLIED BY<br />

CLEVELAND RANGE<br />

22.0"<br />

559<br />

27.3"<br />

693<br />

32.3"<br />

820<br />

6.0"<br />

153<br />

FACTORY RECOMMENDATION: INSTALL CONDENSING UNIT AND HEAT EXCHANGE TANK NEXT TO EACH OTHER<br />

NOTE: GLYCOL SOLUTION NOT SUPPLIED BY CLEVELAND RANGE<br />

Cleveland Range reserves right of design improvement or modification, as warranted.<br />

(NOT TO SCALE)<br />

SECT. XIV PAGE 34<br />

0609<br />

Litho in USA