Han ® HC Individual<br />
4000 V / 350 A<br />
Features<br />
• Flexible high-current interface<br />
• Low mating and unmating forces<br />
• Stackable due to modular design<br />
• Suitable for HC 350 crimp contacts<br />
• On-board removal tool<br />
Current carrying capacity<br />
The current carrying capacity of the connectors is limited by the<br />
thermal load capability of the contact element material including<br />
the connections and the insulating parts. The derating curve<br />
is therefore valid for currents which flow constantly (non-intermittent)<br />
through each contact element of the connector evenly,<br />
without exceeding the allowed maximum temperature.<br />
Measuring and testing techniques according to<br />
DIN EN 60 512-5<br />
Technical characteristics<br />
Inserts<br />
Number of contacts 3<br />
Electrical data<br />
acc. to EN 61 984 350 A 4000 V 18 kV 3<br />
Rated current<br />
350 A<br />
Rated voltage<br />
4000 V<br />
Rated impulse voltage<br />
18 kV<br />
Pollution degree 3<br />
Termination wire gauge 25 mm² ... 120 mm²<br />
Insulation resistance<br />
≥ 10 10 Ω<br />
Material<br />
polyamide<br />
Limiting temperatures -40 °C ... +125 °C<br />
Flammability acc. to<br />
UL 94 V 0<br />
NFF 16-101/102<br />
I2 / F3<br />
CEN/TS 45545-2:2009 HL 2 / R24 outside<br />
HL1 / R23 inside<br />
FprEN 45545-2:2012 HL 2 / R23 outside<br />
HL1 / R22 inside<br />
Mechanical working life<br />
- mating cycles 500<br />
Degree of protection<br />
acc. to DIN EN 60 529<br />
for coupled connector<br />
IP 66 (IP 68 in preparation)<br />
Cable gland thread M 32<br />
Contacts<br />
Material<br />
copper alloy<br />
Surface<br />
3 μm Ag<br />
Contact resistance<br />
≤ 0.3 mΩ<br />
Crimp terminal<br />
25 mm² ... 120 mm²<br />
Max. insulation diameter 20 mm<br />
Crimp die DIN 46 235<br />
Pressing force requirement 130 kN<br />
Carrier plate and Locking modules<br />
Material<br />
aluminium<br />
Locking<br />
stainless steel<br />
Operating current (A<br />
Mechanical solidness<br />
Vibration test acc. to DIN EN 60 068-2-6<br />
• 5 Hz ... 9 Hz: 15 mm<br />
• 9 Hz ... 150 Hz: 5 g<br />
Shock test acc. to DIN EN 61 373<br />
• 30 g, 18 ms<br />
• 3 axis<br />
Noise acc. to DIN EN 61 373<br />
• Cat. 2<br />
Coding possibilities with 1 coding element (3-poles set):<br />
Ambient temperature (°C)<br />
1 wire gauge: 35 mm²<br />
2 wire gauge: 95 mm²<br />
HC Individual 3-poles<br />
Other coding possibilities on request<br />
97