<strong>Release</strong> <strong>Notes</strong> <strong>SC11</strong> <strong>@CHIP</strong>-<strong>RTOS</strong> <strong>V1.25</strong> Beta<br />

Type: Defect, Component: Filesystem (2 item(s))<br />

CR Number: 1476<br />

Type: Defect<br />

Component: Filesystem<br />

Category: Path length<br />

Synopsis: Creating a deep directory structure leeds to stack overflow<br />

Description: If one creates an as deep as possible directory structure (a:\x\x\x\x\x\...\x\), the stack of the<br />

main task overflows.<br />

Fix: Fixed<br />

CR Number: 1551<br />

Type: Defect<br />

Component: Filesystem<br />

Category: Rename command<br />

Synopsis: Rename should not be permitted if file or directory is in use<br />

Description: Rename WEB directory to WEB1 on SC1x3 and observe that DIR command then<br />

indicates "WEB1 (WEB)" for this directories new name. System becomes confused.<br />

Fix: Prevent name changed when a file system object is in use (e.g. when a directory is used<br />

as a "Current Working Directory" by some task.)<br />

Type: Defect, Component: Int21h (1 item(s))<br />

CR Number: 1452<br />

Type: Defect<br />

Component: Int21h<br />

Category: Function 0x68<br />

Synopsis: Function doesn't work<br />

Description: The function always returns error code 2 (Invalid handle).<br />

Fix: Fixed<br />

Type: Defect, Component: <strong>RTOS</strong> API (1 item(s))<br />

CR Number: 1557<br />

Type: Defect<br />

Component: <strong>RTOS</strong> API<br />

Category: Wait on Events<br />

Synopsis: Negative timeout argument , used for polling events, should return error code -27 for<br />

timeout if events not ready.<br />

Description: Currently a polling with negative timeout parameter returns -48 (= INVALID TIME ARG) if<br />

no event is ready.<br />

Fix: Correct Event Wait function in <strong>RTOS</strong><br />

Type: Defect, Component: TCPIP stack (2 item(s))<br />

CR Number: 1451<br />

Type: Defect<br />

Component: TCPIP stack<br />

Category: DHCP client<br />

Synopsis: Gateway option<br />

Description: At the following situation the SC1x DHCP client works not correct: The DHCP client has<br />

received a valid gateway ip address from the DHCP server and set it as its default<br />

gateway.<br />

Because of a possible configuration change of the DHCP servers configuration, the DHCP<br />

server no longer offers at further DHCP requests (e.g. forced by shell command ipeth) a<br />

gateway address to the SC1x client. In that case, the SC1x wrongly still accepts the old<br />

gateway address, instead of erasing it.<br />

Fix: Fixed<br />

CR Number: 1504<br />

Type: Defect