ASSEMBLY AND INSTALLATION INSTRUCTIONS<br />
190<br />
R<br />
ASSEMBLY AND INSTALLATION INSTRUCTIONS<br />
DISTANCE BETWEEN THE SUPPORTS IN cm AT STANDARD TEMPERATURE:<br />
Ø mm 20°C 30°C 40°C 50°C 60°C 70°C 80°C<br />
16 75 70 70 65 65 60 55<br />
20 80 75 70 70 65 60 60<br />
25 85 85 85 80 75 75 70<br />
32 100 95 90 85 80 75 70<br />
40 110 110 105 100 95 90 85<br />
50 125 120 115 110 105 100 90<br />
63 140 135 130 125 120 115 105<br />
75 150 150 140 140 125 115 105<br />
90 165 160 150 150 140 125 115<br />
110 190 180 170 170 160 140 130<br />
Fig. 4<br />
Curvature<br />
It is possible to make the curves by using hot air blowers (industrial dryers); the radius of the<br />
curves must be ≥ 8 times the pipe diameter.<br />
Use of flame is absolutely not recommended.<br />
DIAGRAM OF THE RADIUSES OF CURVATURE<br />
Ø pipes<br />
cold curvature (R = 8xd)<br />
20 160<br />
25 200<br />
32 256<br />
40 320<br />
50 400<br />
63 500