The Siemon Company <strong>Cable</strong> <strong>Catalog</strong><br />

Cabling for the future means selecting the best telecommunications<br />

products today. The Siemon Company’s balanced twisted-pair copper and<br />

fiber cables are a perfect complement to our world-class connecting hardware<br />

and are an intregal part of the Siemon Cabling System ® .<br />

The Siemon Cabling System ® provides an end-to-end solution for your<br />

telecommunications cabling needs. It is a standards-based structured cabling<br />

system for voice, data, image and other information technologies based on<br />

100 ohm category 3, 5, 5e*, 6* unshielded twisted-pair (UTP); category 5e*<br />

and 6* screened twisted-pair (ScTP); category 7* shielded twisted pair, and<br />

50/125µm and 62.5/125µm multimode and singlemode optical fiber cabling.<br />

All of our cabling products are designed to deliver performance that exceeds<br />

today’s cabling industry standards and we offer a complete range of products<br />

to suit any cabling need. To ensure that your cabling systems are futureproofed,<br />

"Specify Siemon - The System of Choice”.<br />

*At the time of printing this catolog, category 5e, 6 and 7 specifications<br />

were under development by TIA/EIA and ISO/IEC.<br />

Visit us at our web site at:<br />

www.siemon.com<br />

The information contained herein is a guide to product selection and is<br />

believed to be true and accurate. However, The Siemon Company reserves the<br />

right to change the contents and cable specifications without prior notice. The<br />

Siemon Company recommends that premise cabling always be installed by a<br />

trained professional.<br />

© 1999 The Siemon Company


PRODUCT SELECTION<br />

SECTION 1<br />

SECTION 2<br />

COPPER CABLES FIBER CABLES<br />

3


TABLE OF CONTENTS<br />

SECTION 1— COPPER<br />

PAGE<br />

Category 3 and Category 5 <strong>Cable</strong><br />

COPPER CABLES<br />

Solid—Riser/Plenum/General Purpose/Residential/LSOH<br />

Category 3<br />

• 4-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6<br />

• 25-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7<br />

• 50-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br />

• 100-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br />

Category 5<br />

• 25-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10<br />

• 50-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11<br />

• 100-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br />

Category 5e* <strong>Cable</strong><br />

Solid—Riser/Plenum/General Purpose/Residential/LSOH<br />

• 4-Pair UTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13<br />

• 4-Pair ScTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />

* All Siemon 4-pair cables are compliant to the requirements of proposed ANSI/TIA/EIA-568-A-5<br />

category 5e requirements. The ‘568-A-5 category 5e requirements are not applicable to the<br />

specification of multi-pair cables.<br />

Category 6* <strong>Cable</strong><br />

Solid—Riser/Plenum/General Purpose/Residential/LSOH<br />

• 4-Pair UTP (Round) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15<br />

• 4-Pair UTP (Flat) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16<br />

• 4-Pair ScTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17<br />

* All Siemon 4-pair cables satisfy the minimum proposed ISO category 6 requirements.<br />

Category 7* <strong>Cable</strong><br />

Solid—Riser/Plenum/LSOH<br />

• 2-Pair STP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />

• 4-Pair STP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18<br />

* All Siemon 4-pair cables satisfy the minimum proposed TIA and ISO category 7 requirements.<br />

• Color Code Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />

• Fire Rating Reference & NVP Charts . . . . . . . . . . . . . . . . . . . . . . . . . . . .19<br />

• Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33<br />

• Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35<br />

• Acronyms & Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

4


TABLE OF CONTENTS<br />

SECTION 2 — FIBER<br />

PAGE<br />

Loose Tube <strong>Cable</strong><br />

Outside Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-23<br />

• Singlemode, 50/125µm and 62.5/125µm multimode<br />

Distribution <strong>Cable</strong><br />

Inside Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24-29<br />

Riser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24-25<br />

Plenum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-27<br />

LSOH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-29<br />

• Singlemode, 50/125µm and 62.5/125µm multimode<br />

Interconnect <strong>Cable</strong><br />

Simplex & Duplex Zipcord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-31<br />

• Singlemode, 50/125µm and 62.5/125µm multimode<br />

FIBER CABLES<br />

• Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33<br />

• Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35<br />

• Acronyms & Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36<br />

5


Category 3, 5, 5e, 6 and 7 Copper <strong>Cable</strong>s<br />

All Siemon 4-pair cables satisfy both ANSI/TIA/EIA-568-A and<br />

ISO/IEC 11801 category transmission requirements. In instances<br />

where there is a conflict in standards performance specifications,<br />

Siemon 4-pair cables satisfy the more stringent requirements. In<br />

accordance with industry trends, all Siemon multi-pair cables<br />

satisfy ANSI/TIA/EIA-568-A category transmission requirements.<br />

Our cables are available for use in plenum, riser, general purpose<br />

(IEC 332.1), LS0H/IEC 332.3c, and LS0H/IEC 332.1<br />

environments.<br />

In addition to the parameters specified in ’568-A and ‘11801, our<br />

cables also satisfy performance requirements for the additional<br />

parameters of: propagation delay, delay skew (per TIA/EIA-568-A-<br />

1), and balance (Longitudinal Conversion Loss). All of our<br />

category 5e cables satisfy the power sum NEXT, ELFEXT, and<br />

power sum ELFEXT requirements of SP-4195-B (proposed<br />

addendum 5 to ‘568-A) and FDAM 3 (proposed amendment 2 to<br />

‘11801).<br />

A note about standards:<br />

Category 3: ANSI/TIA/EIA-568-A and ISO/IEC 11801 specify<br />

category 3 requirements for 4-pair and multi-pair cable.<br />

Category 5: ANSI/TIA/EIA-568-A and ISO/IEC 11801 specify<br />

category 5 requirements for 4-pair and multi-pair cable. Since the<br />

drafting of the proposed category 5e requirements for 4-pair<br />

cables, the ‘568-A and ‘11801 category 5 requirements are only<br />

applicable for the specification of multi-pair horizontal and<br />

backbone cable performance.<br />

Category 5e: Proposed addendum 5 to ANSI/TIA/EIA-568-A<br />

specifies enhanced category 5 performance requirements. These<br />

requirements are recommended for new 4-pair category 5 cabling<br />

installations and are expected to become the de facto minimum<br />

standard for category 5 cabling. To ensure additional crosstalk<br />

headroom for robust applications support, it also specifies power<br />

sum performance requirements for category 5e cables and<br />

cabling. This document specifies performance for 4-pair cables<br />

only (i.e. category 5e is not applicable for multi-pair cable<br />

specification).<br />

Category 6/Class E: This is a new performance range for<br />

unshielded and screened twisted-pair cabling. Category 6/Class<br />

E is intended to specify the best performance that UTP and ScTP<br />

cabling solutions can be designed to deliver. It is anticipated that<br />

category 6/class E components and cable will be characterized<br />

over the frequency range of at least 1-250 MHz. The Siemon<br />

company is actively involved in the development of these industry<br />

standards and has developed the System 6 SM solution to<br />

guarantee future category 6/class E applications support.<br />

Category 7/Class F: Proposed category 7/class F describes a<br />

new performance range for fully shielded twisted-pair cabling.<br />

Even though these requirements are expected to be supported by<br />

an entirely new interface design (i.e., plug and socket), category<br />

7/class F will be backward compatible which means that<br />

applications running on lower categories/classes would also be<br />

supported.


CATEGORY 3<br />

4-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C3R4<br />

9C3X4<br />

COPPER CABLES<br />

9C3R4<br />

9C3R4-W<br />

9C3P4<br />

9C3P4-W<br />

9C3X4<br />

9C3L4<br />

9C3L4-G<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Riser (CMR, CSA FT4), Gray Jacket,<br />

‘568-A and ‘11801 compliant<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket,<br />

‘568-A and ‘11801 compliant<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket,<br />

ISO/IEC 11801 category 3<br />

COMPLIANCE<br />

• ANSI/TIA/EIA-568-A and ‘568-A-1 category 3<br />

• Qualified for Propagation Delay and Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T<br />

• 4 Mbps Token Ring<br />

• 51 Mbps ATM<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4-pairs cabled together with a rip cord<br />

• 5.46mm (0.22 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

9C3P4<br />

9C3L4<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

DC Resistance (max)<br />

@ 20° C (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-10 MHz<br />

10-16 MHz<br />

Characteristic Impedance<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

(‘11801 only)<br />

4-Pair<br />

9.4 ohms/100m<br />

35 ns/100m<br />

12 dB<br />

12-10log(f/10) dB<br />

100 ohms ± 15%<br />

100 ohms ± 15%<br />

Maximum Minimum Maximum<br />

Frequency Attenuation NEXT Loss Propagation Delay<br />

(MHz) (dB/100m) (Worst Pair) (ns/100m)<br />

(dB)<br />

0.772 2.2 43 —<br />

1 2.6 41 570<br />

4 5.6 32 552<br />

8 8.5 27 547<br />

10 9.7 26 545<br />

16 13.1 23 543<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

8


CATEGORY 3<br />

25-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9C3R25<br />

9C3P25<br />

9C3X25<br />

9C3L25<br />

9C3L25-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/TIA/EIA-568-A and ‘568-A-1 category 3<br />

• Qualified for Propagation Delay and Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T<br />

• 4 Mbps Token Ring<br />

• 51 Mbps ATM<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 25-pairs cabled together with a rip cord and<br />

and colored core binder<br />

• 9.14mm (0.36 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

9C3R25<br />

9C3X25<br />

9C3P25<br />

9C3L25<br />

COPPER CABLES<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

@ 20° C (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-10 MHz<br />

10-16 MHz<br />

Characteristic Impedance<br />

9.4 ohms/100m<br />

35 ns/100m<br />

12 dB<br />

12-10log(f/10) dB<br />

100 ohms ± 15%<br />

TRANSMISSION PERFORMANCE<br />

25-Pair Maximum Minimum Maximum<br />

Frequency Attenuation NEXT Loss Propagation Delay<br />

(MHz) (dB/100m) (Worst Pair) (ns/100m)<br />

(dB)<br />

0.772 2.2 43 —<br />

1 2.6 41 570<br />

4 5.6 32 552<br />

8 8.5 27 547<br />

10 9.7 26 545<br />

16 13.1 23 543<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

9


CATEGORY 3<br />

50-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C3R50<br />

9C3X50<br />

COPPER CABLES<br />

9C3R50<br />

9C3P50<br />

9C3X50<br />

9C3L50<br />

9C3L50-G<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/TIA/EIA-568-A and ‘568-A-1 category 3<br />

• Qualified for Propagation Delay and Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T<br />

• 4 Mbps Token Ring<br />

• 51 Mbps ATM<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 2 sections 25-pairs cabled together with a<br />

rip cord and colored core binder<br />

• 12.57mm (0.50 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

9C3P50<br />

9C3L50<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

DC Resistance (max)<br />

@ 20° C (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-10 MHz<br />

10-16 MHz<br />

Characteristic Impedance<br />

50-Pair<br />

9.4 ohms/100m<br />

35 ns/100m<br />

12 dB<br />

12-10log(f/10) dB<br />

100 ohms ± 15%<br />

Maximum Minimum Maximum<br />

Frequency Attenuation NEXT Loss Propagation Delay<br />

(MHz) (dB/100m) (Worst Pair) (ns/100m)<br />

(dB)<br />

0.772 2.2 43 —<br />

1 2.6 41 570<br />

4 5.6 32 552<br />

8 8.5 27 547<br />

10 9.7 26 545<br />

16 13.1 23 543<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

10


CATEGORY 3<br />

100-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C3R100<br />

9C3X100<br />

9C3R100 Riser (CMR, CSA FT4), Gray Jacket<br />

9C3P100 Plenum (CMP, CSA FT6), Blue Jacket<br />

9C3X100 CMX (IEC 332.1), Gray Jacket<br />

9C3L100 LS0H (IEC 332.1), Violet Jacket<br />

9C3L100-G LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/TIA/EIA-568-A and ‘568-A-1 category 3<br />

• Qualified for Propagation Delay and Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T<br />

• 4 Mbps Token Ring<br />

• 51 Mbps ATM<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4 sections 25-pairs cabled together with a<br />

rip cord and colored core binder<br />

• 16.89mm (0.67 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

9C3P100<br />

9C3L100<br />

COPPER CABLES<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

DC Resistance (max)<br />

@ 20° C (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-10 MHz<br />

10-16 MHz<br />

Characteristic Impedance<br />

100-Pair<br />

9.4 ohms/100m<br />

35 ns/100m<br />

12 dB<br />

12-10log(f/10) dB<br />

100 ohms ± 15%<br />

Maximum Minimum Maximum<br />

Frequency Attenuation NEXT Loss Propagation Delay<br />

(MHz) (dB/100m) (Worst Pair) (ns/100m)<br />

(dB)<br />

0.772 2.2 43 —<br />

1 2.6 41 570<br />

4 5.6 32 552<br />

8 8.5 27 547<br />

10 9.7 26 545<br />

16 13.1 23 543<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

11


CATEGORY 5<br />

25-Pair Solid <strong>Cable</strong><br />

COPPER CABLES<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9C5R25<br />

9C5P25<br />

9C5X25<br />

9C5L25<br />

9C5L25-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/ TIA/EIA-568-A and ’568-A-1 category 5<br />

• Power Sum NEXT<br />

• Qualified for ELFEXT, Propagation Delay and<br />

Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE-T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 25-pairs cabled together with a rip cord and<br />

a core binder<br />

• 9.14mm (0.36 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

• May include internal support member<br />

9C5R25<br />

9C5X25<br />

9C5P25<br />

9C5L25<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

12<br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-20 MHz<br />

20-100 MHz<br />

Characteristic Impedance<br />

25-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

35 ns/100m<br />

23 dB<br />

23-10log(f/20) dB<br />

100 ohms ± 15%<br />

Maximum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Power Sum) (Pair-to-Pair) (ns/100m)<br />

(dB)<br />

(dB)<br />

0.772 1.8 64 — —<br />

1 2.0 62 61 570<br />

4 4.1 53 49 552<br />

8 5.8 49 43 547<br />

10 6.5 47 41 545<br />

16 8.2 44 37 543<br />

20 9.3 43 35 542<br />

25 10.4 41 33 541<br />

31.25 11.7 40 31 540<br />

62.5 17.0 35 25 539<br />

100 22.0 32 21 538<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.


CATEGORY 5<br />

50-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9C5R50<br />

9C5P50<br />

9C5X50<br />

9C5L50<br />

9C5L50-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/ TIA/EIA-568-A and ’568-A-1 category 5<br />

• Power Sum NEXT<br />

• Qualified for ELFEXT, Propagation Delay,<br />

Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE-T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4 sections cabled together with a<br />

rip cord and a colored core binder<br />

• 12.57mm (0.50 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

• May include internal support member<br />

9C5R50<br />

9C5X50<br />

9C5P50<br />

9C550<br />

COPPER CABLES<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-20 MHz<br />

20-100 MHz<br />

Characteristic Impedance<br />

50-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

35 ns/100m<br />

23 dB<br />

23-10log(f/20) dB<br />

100 ohms ± 15%<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

Maximum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Power Sum) (Pair-to-Pair) (ns/100m)<br />

(dB) (dB/100m)<br />

0.772 1.8 64 — —<br />

1 2.0 62 61 570<br />

4 4.1 53 49 552<br />

8 5.8 49 43 547<br />

10 6.5 47 41 545<br />

16 8.2 44 37 543<br />

20 9.3 45 35 542<br />

25 10.4 41 33 541<br />

31.25 11.7 40 31 540<br />

62.5 17.0 35 25 539<br />

100 22.0 32 21 538<br />

13


CATEGORY 5<br />

100-Pair Solid <strong>Cable</strong><br />

COPPER CABLES<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C5R100 Riser (CMR, CSA FT4), Gray Jacket<br />

9C5P100 Plenum (CMP, CSA FT6), Blue Jacket<br />

9C5X100 CMX (IEC 332.1), Gray Jacket<br />

9C5L100 LS0H (IEC 332.1), Violet Jacket<br />

9C5L100-G LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• ANSI/ TIA/EIA-568-A and ’568-A-1 category 5<br />

• Power Sum NEXT<br />

• Qualified for ELFEXT, Propagation Delay and<br />

Delay Skew<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100Base-T, 1000Base T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4 sections 25-pairs cabled together with a<br />

rip cord and a colored core binder<br />

• 16.89mm (0.67 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

• May include internal support member<br />

9C5R100<br />

9C5X100<br />

9C5P100<br />

9C5L100<br />

14<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Structural Return Loss (min)<br />

1-20 MHz<br />

20-100 MHz<br />

Characteristic Impedance<br />

100-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

35 ns/100m<br />

23 dB<br />

23-10log(f/20) dB<br />

100 ohms ± 15%<br />

TRANSMISSION PERFORMANCE<br />

<strong>Cable</strong> supplied on a reel, 305m (1,000 ft.)<br />

Maximum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Power Sum) (Pair-to-Pair) (ns/100m)<br />

(dB)<br />

(dB)<br />

0.772 1.8 64 — —<br />

1 2.0 62 61 570<br />

4 4.1 53 49 552<br />

8 5.8 49 43 547<br />

10 6.5 47 41 545<br />

16 8.2 44 37 543<br />

20 9.3 43 35 542<br />

25 10.4 41 33 541<br />

31.25 11.7 40 31 540<br />

62.5 17.0 35 25 539<br />

100 22.0 32 25 538<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.


CATEGORY 5e<br />

4-Pair Solid <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9C5R4<br />

9C5P4<br />

9C5X4<br />

9C5L4<br />

9C5L4-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• Proposed ANSI/TIA/EIA-568-A-5 category 5e<br />

• ANSI/ TIA/EIA-568-A and ’568-A-1 category 5<br />

• ISO/IEC 11801 and FDAM 3 category 5<br />

• Qualified for ELFEXT, Propagation Delay,<br />

Delay Skew, and Balance (LCL)<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE-T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4-pairs cabled together with a rip cord<br />

• 5.46mm (0.22 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

9C5R4<br />

9C5X4<br />

9C5P4<br />

9C5L4<br />

COPPER CABLES<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Return Loss (min)<br />

1 ≤ f < 10<br />

10 ≤ f < 20<br />

20 ≤ f < 100<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

4-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

35 ns/100m<br />

20 + 5log(f) dB<br />

25 dB<br />

25 - 7log(f/20) dB<br />

100 ohms ± 15%<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

TRANSMISSION PERFORMANCE<br />

Maximum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Power Sum) (Power Sum) (ns/100m)<br />

(dB/100m) (dB/100m)<br />

0.772 1.8 64 — —<br />

1 2.0 62 61 570<br />

4 4.1 53 49 552<br />

8 5.8 49 43 547<br />

10 6.5 47 41 545<br />

16 8.2 44 37 543<br />

20 9.3 43 35 542<br />

25 10.4 41 33 541<br />

31.25 11.7 40 31 540<br />

62.5 17.0 35 25 539<br />

100 22.0 32 21 538<br />

15


CATEGORY 5e<br />

4-Pair Solid ScTP <strong>Cable</strong><br />

COPPER CABLES<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9A5R4<br />

9A5P4<br />

9A5X4<br />

9A5L4<br />

9A5L4-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• Proposed ANSI/TIA/EIA-568-A-5 category 5e<br />

• ANSI/ TIA/EIA-568-A and ’568-A-1 category 5<br />

• ISO/IEC 11801 and FDAM 3 category 5<br />

• Qualified for ELFEXT, Propagation Delay,<br />

Delay Skew, and Balance (LCL)<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE-T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 4-pairs cabled together with a rip cord<br />

• 6.10mm (0.24 in.) max jacket diameter<br />

• 1.07mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Shield is 0.05mm (0.002 in.) foil tape<br />

enclosing a solid 0.51mm (24AWG)<br />

tinned copper drain wire<br />

• Sequential meter markings on jacket<br />

9A5R4<br />

9A5X4<br />

9A5P4<br />

9A5L4<br />

16<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Return Loss (min)<br />

1 ≤ f < 10<br />

10 ≤ f < 20<br />

20 ≤ f < 100<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

Transfer Impedance<br />

(max)<br />

4-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

35 ns/100m<br />

20 + 5log(f) dB<br />

25 dB<br />

25 - 7log(f/20) dB<br />

100 ohms ± 15%<br />

37 + 4f + 4f 1/2<br />

+ 5f 1/3 mΩ/m<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

TRANSMISSION PERFORMANCE<br />

Maximum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss ELFEXT Loss Propagation Delay<br />

(MHz) (dB/100m) (Power Sum) (Power Sum) (ns/100m)<br />

(dB)<br />

(dB)<br />

0.772 1.8 64 66 —<br />

1 2.0 62 61 570<br />

4 4.1 53 49 552<br />

8 5.8 49 43 547<br />

10 6.5 47 41 545<br />

16 8.2 44 37 543<br />

20 9.3 43 35 542<br />

25 10.4 41 33 541<br />

31.25 11.7 40 31 540<br />

62.5 17.0 35 25 539<br />

100 22.0 32 21 538<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.


CATEGORY 6<br />

4-Pair Solid <strong>Cable</strong> Round<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C6R4<br />

9C6X4<br />

9C6R4<br />

9C6P4<br />

9C6X4<br />

9C6L4<br />

9C6L4-G<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• Proposed ISO/IEC and TIA category 6<br />

• Exceeds ANSI/TIA/EIA/-568-A and ‘568-A-1<br />

category 5, ISO/IEC 11801 and FDAM 3<br />

category 5, and ‘568-A-5 category 5e<br />

• Power Sum NEXT and ELFEXT<br />

• Qualified for ELFEXT, Propagation Delay,<br />

Delay Skew, and LCL<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE- T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 5.84mm (0.23 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Sequential meter markings on jacket<br />

• Internal support member<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

9C6P4<br />

9C6L4<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

TRANSMISSION PERFORMANCE<br />

COPPER CABLES<br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Return Loss (min)<br />

1 ≤ f < 10<br />

10 ≤ f < 20<br />

20 ≤ f < 100<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

1 ≤ f ≤ 100<br />

1 ≤ f ≤ 200<br />

1 ≤ f ≤ 300<br />

4-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

25 ns/100m<br />

20 + 5log(f) dB<br />

25 dB<br />

25 - 7log(f/20) dB<br />

100 ohms ± 15%<br />

100 ohms ± 22%<br />

100 ohms ± 32%<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

Maximum Minimum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss NEXT ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Pair-to-Pair) (Power Sum) (Power Sum) (ns/100m)<br />

(dB) (dB) (dB)<br />

1 2.0 74 72 65 570<br />

4 3.7 65 63 53 552<br />

10 5.9 59 57 45 547<br />

16 7.6 56 54 41 545<br />

20 8.5 55 53 39 543<br />

25 9.5 53 51 37 542<br />

31.25 10.7 52 50 35 541<br />

62.5 15.5 47 45 29 540<br />

100 19.9 44 42 25 539<br />

200 29.1 40 38 19 538<br />

250 33.0 38 36 17 537<br />

17


CATEGORY 6<br />

4-Pair Solid <strong>Cable</strong> Flat<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

DESCRIPTION<br />

9C6R4<br />

9C6R4-F<br />

9C6P4-F<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

COPPER CABLES<br />

COMPLIANCE<br />

• Proposed ISO/IEC and TIA PN-3727 category 6<br />

• Exceeds ANSI/TIA/EIA/-568-A and ‘568-A-1<br />

category 5, ISO/IEC 11801 and FDAM 3<br />

category 5, and ‘568-A-5 category 5e<br />

• Power Sum NEXT and ELFEXT<br />

• Qualified for ELFEXT, Delay, Skew, and LCL<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE- T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Flat jacket construction<br />

• Sequential meter markings on jacket<br />

9C6P4<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

TRANSMISSION PERFORMANCE<br />

18<br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Return Loss (min)<br />

1 ≤ f < 10<br />

10 ≤ f < 20<br />

20 ≤ f < 100<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

1 ≤ f ≤ 100<br />

1 ≤ f ≤ 200<br />

1 ≤ f ≤ 300<br />

4-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

25 ns/100m<br />

20 + 5log(f) dB<br />

25 dB<br />

25 - 7log(f/20) dB<br />

100 ohms ± 15%<br />

100 ohms ± 22%<br />

100 ohms ± 32%<br />

Maximum Minimum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss NEXT ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Pair-to-Pair) (Power Sum) (Power Sum) (ns/100m)<br />

(dB) (dB) (dB)<br />

1 2.0 74 72 65 570<br />

4 3.7 65 63 53 552<br />

10 5.9 59 57 45 547<br />

16 7.6 56 54 41 545<br />

20 8.5 55 53 39 543<br />

25 9.5 53 51 37 542<br />

31.25 10.7 52 50 35 541<br />

62.5 15.5 47 45 29 540<br />

100 19.9 44 42 25 539<br />

200 29.1 40 38 19 538<br />

250 33.0 38 36 17 537<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.


CATEGORY 6<br />

4-Pair Solid ScTP <strong>Cable</strong><br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9A6R4<br />

9A6P4<br />

9A6X4<br />

9A6L4<br />

9A6L4-G<br />

DESCRIPTION<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

COMPLIANCE<br />

• Proposed ISO/IEC and TIA category 6<br />

• Exceeds ANSI/TIA/EIA/-568-A and ‘568-A-1<br />

category 5, ISO/IEC 11801 and FDAM 3<br />

category 5, and ‘568-A-5 category 5e<br />

• Power Sum NEXT and ELFEXT<br />

• Qualified for ELFEXT, Delay, Skew, and LCL<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE- T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.51mm (24 AWG) solid bare copper<br />

• 6.10mm (0.24 in.) max jacket diameter<br />

• 0.97mm (0.04 in.) max conductor<br />

insulation diameter<br />

• Shield is 0.05mm (0.002 in.) foil tape<br />

enclosing a solid 0.15mm (24 AWG)<br />

tinned copper drain wire<br />

• Sequential meter markings on jacket<br />

• Internal support member<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

Delay Skew (max)<br />

Return Loss (min)<br />

1 ≤ f < 10<br />

10 ≤ f < 20<br />

20 ≤ f < 100<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

1 ≤ f ≤ 100<br />

1 ≤ f ≤ 200<br />

1 ≤ f ≤ 300<br />

4-Pair<br />

9.4 ohms/100m<br />

@ 20° C<br />

25 ns/100m<br />

20 + 5log(f) dB<br />

25 dB<br />

25 - 7log(f/20) dB<br />

100 ohms ± 15%<br />

100 ohms ± 22%<br />

100 ohms ± 32%<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.<br />

9A6R4<br />

9A5X4<br />

9A6P4<br />

9A6L4<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

TRANSMISSION PERFORMANCE<br />

Maximum Minimum Minimum Minimum Maximum<br />

Frequency Attenuation NEXT Loss NEXT ELFEXT Propagation Delay<br />

(MHz) (dB/100m) (Pair-to-Pair) (Power Sum) (Power Sum) (ns/100m)<br />

(dB) (dB) (dB)<br />

1 2.0 74 72 65 570<br />

4 3.7 65 63 53 552<br />

10 5.9 59 57 45 547<br />

16 7.6 56 54 41 545<br />

20 8.5 55 53 39 543<br />

25 9.5 53 51 37 542<br />

31.25 10.7 52 50 35 541<br />

62.5 15.5 47 45 29 540<br />

100 19.9 44 42 25 539<br />

200 29.1 40 38 19 538<br />

250 33.0 38 36 17 537<br />

19<br />

COPPER CABLES


CATEGORY 7<br />

2-Pair (Oval) & 4-Pair (Round) Solid <strong>Cable</strong><br />

COPPER CABLES<br />

20<br />

PART NUMBERS AND DESCRIPTION:<br />

P/N<br />

9C7R(X)<br />

9C7P(X)<br />

9C7X(X)<br />

9C7L(X)<br />

9C7L(X)-G<br />

COMPLIANCE<br />

• Proposed ISO/IEC Class F<br />

• Significantly exceeds ANSI/TIA/EIA/-568-A<br />

and ‘568-A-1 category 5, ISO/IEC 11801 and<br />

FDAM 3 category 5, and ‘568-A-5 category 5e<br />

APPLICATIONS<br />

• Voice<br />

• T1<br />

• 10BASE-T, 100BASE-T, 1000BASE- T<br />

• 4/16 Mbps Token Ring<br />

• 51/155 Mbps ATM, 100Mbps TP-PMD<br />

• 100VG-AnyLAN<br />

PRODUCT CONSTRUCTION<br />

• 0.55mm (23 AWG) solid bare copper<br />

• 2-pair (oval): 8.4mm (0.33 in) x 17.0mm<br />

(0.67 in.) diameter<br />

• 4-pair (round): 8.50mm (0.33 in.) max jacket<br />

diameter<br />

• Pairs individually shielded with aluminumpolyester<br />

foil<br />

• Tinned copper braid and drain wire<br />

• Sequential meter markings on jacket<br />

• Exceeds DIN 44312-5 600MHz cable<br />

requirements<br />

ELECTRICAL CHARACTERIST<strong>ICS</strong><br />

DC Resistance (max)<br />

Delay Skew (max)<br />

DESCRIPTION<br />

Return Loss (min)<br />

1 0≤ f < 300<br />

300 ≤ f < 600<br />

Input Impedance<br />

(no impedance averaging allowed)<br />

1 < f ≤ 100<br />

100 < f ≤ 160<br />

160 < f ≤ 200<br />

200 < f ≤ 600<br />

Riser (CMR, CSA FT4), Gray Jacket<br />

Plenum (CMP, CSA FT6), Blue Jacket<br />

CMX (IEC 332.1), Gray Jacket<br />

LS0H (IEC 332.1), Violet Jacket<br />

LS0H (IEC 332.3c), Violet Jacket<br />

Use (X) to specify cable type: 2 = 2-pair, 4 = 4-pair<br />

2 & 4-Pair<br />

8.2 ohms/100m<br />

@ 20° C<br />

25 ns/100m<br />

@ 10-900 MHz<br />

21dB<br />

21-10log(f/300)dB<br />

100 ohms ± 15%<br />

100 ohms ± 20%<br />

100 ohms ± 22%<br />

100 ohms ± 25%<br />

9C7R4<br />

9C7P4<br />

9C7L4<br />

<strong>Cable</strong> supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.)<br />

*Alternate packaging may also be available, contact your<br />

local Siemon Sales Representative for more information<br />

TRANSMISSION PERFORMANCE<br />

Maximum Minimum Minimum<br />

Frequency Attenuation NEXT Loss ELFEXT<br />

(MHz) (dB/100m) (Pair-to-Pair) (Pair-to-Pair)<br />

(dB)<br />

(dB/100m)<br />

1 1.9 80 80<br />

4 3.6 80 68<br />

10 5.6 80 60<br />

16 7.1 80 56<br />

20 7.9 80 54<br />

31.25 10.0 80 50<br />

62.5 14.3 75 44<br />

100 18.2 71 40<br />

200 26.4 66 34<br />

250 29.8 65 32<br />

300 32.9 64 30<br />

600 48.3 60.0 24<br />

For color chart see page 19<br />

Contact your local sales representative<br />

for cable availability, and delivery lead time.<br />

<strong>Cable</strong> designs and specifications subject to change without notice.


TECHNICAL INFORMATION<br />

Color Code Chart for <strong>Cable</strong>s<br />

PAIR<br />

NO.<br />

RING CONDUCTOR<br />

TIP CONDUCTOR<br />

INSULATION COLOR BAND MARK INSULATION COLOR BAND MARK<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

24<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

White<br />

White<br />

White<br />

White<br />

White<br />

Red<br />

Red<br />

Red<br />

Red<br />

Red<br />

Black<br />

Black<br />

Black<br />

Black<br />

Black<br />

Yellow<br />

Yellow<br />

Yellow<br />

Yellow<br />

Yellow<br />

Violet<br />

Violet<br />

Violet<br />

Violet<br />

Violet<br />

White<br />

White<br />

White<br />

White<br />

White<br />

Red<br />

Red<br />

Red<br />

Red<br />

Red<br />

Black<br />

Black<br />

Black<br />

Black<br />

Black<br />

Yellow<br />

Yellow<br />

Yellow<br />

Yellow<br />

Yellow<br />

Violet<br />

Violet<br />

Violet<br />

Violet<br />

Violet<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Blue<br />

Orange<br />

Green<br />

Brown<br />

Slate<br />

Nominal Velocity of<br />

Propagation Chart<br />

PART Velocity of<br />

NUMBER Propagation %<br />

9C6R4 71<br />

9C6P4 72<br />

9C6L4 70<br />

9C6X4 70<br />

9C5R4 70<br />

9C5P4 72<br />

9C5L4 70<br />

9C5X4 70<br />

9C3R4 64<br />

9C3P4 68<br />

9C3L4 64<br />

9C3X4 64<br />

9C5R25 69<br />

9C5P25 71<br />

9C5L25 69<br />

9C5X25 69<br />

COPPER CABLES<br />

National Electrical Code (NEC) and IEC Equivalent Fire Rating Chart<br />

FIRE RESISTANCE LEVEL NEC RATING ARTICLE 800* EQUIVALENT IEC RATING<br />

Plenum (Highest) <strong>Cable</strong>s<br />

Riser <strong>Cable</strong>s<br />

(Multiple Floors)<br />

General Purpose United States<br />

General Purpose Europe<br />

Residential <strong>Cable</strong>s<br />

Restricted Use (Lowest)<br />

CMP/CSA FT6 —<br />

CMR/CSA FT4 —<br />

CM<br />

IEC 332.3, category c<br />

CMX** IEC 332.1<br />

CMX IEC 332.1<br />

*Article 800 of the National Electrical Code specifies fire resistance levels for communication cable for premise installations.<br />

**Equivalent NEC rating.<br />

Notes:<br />

1. <strong>Cable</strong>s with a higher fire resistance rating may be substituted for cables with a lower fire resistance rating<br />

(i.e. a plenum cable may be used for a riser application).<br />

2. <strong>Cable</strong>s rated CM are specified by NEC 800-53 for cables penetrating one floor.<br />

3. LS0H cables satisfy an equivalent NEC fire resistance rating of CM or CMX.<br />

4. Utilization of proper firestopping technologies and procedures are strongly recommended regardless of cable<br />

rating. Follow applicable local and/or national codes.<br />

21


Fiber Optic <strong>Cable</strong>s<br />

Network designs utilizing the advantages offered by optical fiber<br />

are evolving rapidly and the cabling segment of those networks<br />

is the heart of the system. The Siemon Company supplies fiber<br />

optic cables that enable network designers to maximize the<br />

potential that this media can bring to the performance of the<br />

cabling system that integrates data, voice, and video<br />

transmission. The optical performance, durability,<br />

environmental resistance, and overall quality of our cables are<br />

second-to-none. And the available cable construction variants<br />

encompass usage both between and within buildings that are<br />

being cabled for the twenty-first century.<br />

<strong>Cable</strong>s for indoor use are designed with a distribution-style<br />

construction that consists of a 900 micron buffer which is tightly<br />

formed onto the coated fibers. These buffered fibers are<br />

surrounded by strength members made from aramid yarn and<br />

then jacketed with a material that is rugged, yet flexible. Higher<br />

fiber counts are bundled into multi-fiber sub-units for easier<br />

identification and increased fiber protection during storage,<br />

installation, and termination.<br />

<strong>Cable</strong>s designed for outdoor use are constructed with coated<br />

fibers that are surrounded by a moisture-proof gel within rugged,<br />

stress-resistant tubes that are then surrounded by an outer<br />

jacket for additional protection from the elements.<br />

Fibers are bundled within the loose tubes or flexible sub-units in<br />

multiples of four, six or eight to enable usage in all global<br />

markets.<br />

The Siemon Company offers riser and plenum-rated cables plus<br />

low smoke, zero halogen cables that have been designed for the<br />

ever increasing demand for safe, non-toxic premise<br />

installations. These cable material options allow you to make<br />

the choices you need in order to meet international standards<br />

for toxicity, corrosion resistance, low smoke emission, or flame<br />

retardance while maintaining outstanding mechanical integrity<br />

and optical transmission performance. All cables meet or<br />

exceed the applicable requirements of ANSI/TIA/EIA-568-A and<br />

ISO/IEC 11801.


LOOSE TUBE<br />

Outside Plant Fiber Optic <strong>Cable</strong><br />

PART NUMBER & DESCRIPTION:<br />

PART NUMBER<br />

Fiber<br />

Count<br />

# Of Sub-Units<br />

(Fibers/<br />

Sub-Unit)<br />

9F(X)D4-4A(XXXX) 4 Single Unit<br />

9F(X)D4-6B(XXXX) 6 Single Unit<br />

9F(X)D4-8C(XXXX) 8 Single Unit<br />

9F(X)D4-12D(XXXX) 12 Single Unit<br />

9F(X)D4-16A(XXXX) 16 4 (4)<br />

9F(X)D4-72D(XXXX) 72 6 (12)<br />

9F(X)D4-144D(XXXX) 144 12 (12)<br />

4, 6, 8 and 12 FIBER<br />

16 FIBER<br />

FIBER CABLES<br />

Use “X” to specify mode:<br />

5 = 50/125µm Multimode<br />

6 = 62.5/125µm Multimode<br />

8 = Singlemode<br />

Use “XXXX” to specify length in kilometers,<br />

four characters including a decimal point<br />

The last “X” is to be a zero (0) or five (5) only<br />

Add “P” to end of P/N for premium grade performance<br />

Example P/N: 9F6D4-144D1.15P;<br />

(OSP, 62.5/125µm Multimode,144 count, 12 sub-units,<br />

12 fibers/sub-unit, 1.15km length, premium grade)<br />

COMPLIANCE<br />

• ANSI/TIA/EIA-568-A<br />

• ISO/IEC 11801<br />

APPLICATIONS<br />

• Direct burial and underground conduit<br />

• Campus, building-to-building interconnections<br />

• Aerial<br />

• Recommended for optimum ozone,<br />

moisture and weather resistance<br />

PRODUCT CONSTRUCTION/FEATURES<br />

• Thermoplastic inner and outer jackets<br />

• Water-blocking, gel-filled loose tubes<br />

• Aramid yarn strength members<br />

• Dielectric central strength members<br />

• High fiber counts<br />

• Multiple fibers in single tube isolates the<br />

fibers from environmental and mechanical stresses<br />

• Industry standard fiber coating colors are as follows:<br />

blue, orange, green, brown, slate, white, red, black,<br />

yellow, violet, rose and aqua<br />

• Buffer tube colors for 4, 6, 8 & 12 fiber counts: natural<br />

beige. Buffer tube colors for 16, 72 & 144 fiber counts<br />

are in accordance with industry standards, as follows:<br />

blue, orange, green, brown, slate, white, red, black,<br />

yellow, violet, rose and aqua<br />

72 FIBER<br />

144 FIBER<br />

Fiber cable supplied on wooden reels in lengths per order<br />

4, 6, 8 & 12 FIBER<br />

(6 fiber shown)<br />

16 FIBER 72 FIBER 144 FIBER<br />

Note: Illustrations not to scale<br />

<strong>Cable</strong> designs and specifications are<br />

subject to change without notice.<br />

24


LOOSE TUBE<br />

Outside Plant Fiber Optic <strong>Cable</strong><br />

OPTICAL CHARACTERIST<strong>ICS</strong><br />

FIBER<br />

TYPE<br />

50/125<br />

62.5/125<br />

Singlemode<br />

Typical Maximum Minimum Modal Guaranteed<br />

Wavelength Attenuation Attenuation Bandwidth Transmission Distance*<br />

nm (dB/Km) (dB/Km) (MHz-Km) (Meters)<br />

Standard Premium Standard Premium Standard Premium Standard Premium<br />

850 2.6 2.6 3.5 3.0 500 500 550 600<br />

1300 0.6 0.6 1.0 1.0 500 1000 550 600<br />

850 2.9 2.9 3.5 3.5 200 220 275 300<br />

1300 0.9 0.9 1.0 1.0 500 1000 550 550<br />

1310 0.35 0.35 0.5 0.4 N/A N/A N/A N/A<br />

1550 0.25 0.25 0.5 0.3 N/A N/A N/A N/A<br />

PHYSICAL SPECIFICATION<br />

FIBER<br />

COUNT<br />

NOMINAL<br />

CABLE DIAMETER<br />

mm<br />

(in.)<br />

MAXIMUM PULLING TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

MINIMUM BEND RADIUS<br />

Installation<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

4<br />

6<br />

8<br />

12<br />

16<br />

72<br />

144<br />

FIBER<br />

COUNT<br />

8.89<br />

8.89<br />

8.89<br />

8.89<br />

9.78<br />

12.57<br />

16.71<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

(0.350)<br />

(0.350)<br />

(0.350)<br />

(0.350)<br />

(0.385)<br />

(0.495)<br />

(0.658)<br />

2670<br />

(600)<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

600<br />

(135)<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

20 x DIA.<br />

OPERATING<br />

TEMP<br />

(° C)<br />

10 x DIA.<br />

STORAGE<br />

TEMP<br />

(° C)<br />

58 (39)<br />

58 (39)<br />

58 (39)<br />

58 (39)<br />

77 (52)<br />

124 (87)<br />

245 (165)<br />

FIBER CABLES<br />

4<br />

6<br />

8<br />

12<br />

16<br />

72<br />

144<br />

350<br />

350<br />

350<br />

350<br />

875<br />

875<br />

875<br />

1000<br />

2000<br />

-40/80<br />

-40/80<br />

MODE AND FIBER TYPE<br />

CORE SIZE<br />

(MICRONS)<br />

CLADDING SIZE<br />

(MICRONS)<br />

COATING SIZE<br />

(MICRONS)<br />

50/125 M/M<br />

50 ± 3<br />

125 ± 2<br />

62.5/125 M/M<br />

62.5 ± 3<br />

125 ± 2<br />

250 ± 15<br />

Singlemode<br />

8.3 ± 1<br />

125 ± 1<br />

*The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z.<br />

Contact your local sales representative for cable<br />

availability, and delivery lead time.<br />

25


DISTRIBUTION<br />

Riser Rated Fiber Optic <strong>Cable</strong><br />

PART NUMBER & DESCRIPTION:<br />

PART NUMBER<br />

Fiber<br />

Count<br />

# Of Sub-Units<br />

(Fibers/<br />

Sub-Unit)<br />

9F(X)B1--4A(XXXX) 4 Single Unit<br />

9F(X)B1-6B(XXXX) 6 Single Unit<br />

9F(X)B1-12D(XXXX) 12 Single Unit<br />

9F(X)B1-24B(XXXX) 24 4 (6)<br />

9F(X)B1-48D(XXXX) 48 4 (12)<br />

9F(X)B1-72D(XXXX) 72 6 (12)<br />

9F(X)B1-96D(XXXX) 96 8 (12)<br />

4 & 6 FIBER<br />

12 FIBER<br />

FIBER CABLES<br />

Use “X” to specify mode:<br />

5 = 50/125µm Multimode<br />

6 = 62.5/125µm Multimode<br />

8 = Singlemode<br />

Use “XXXX” to specify length in kilometers,<br />

four characters including a decimal point<br />

The last “X” is to be a zero (0) or five (5) only<br />

Add “P” to end of P/N for premium grade performance<br />

Example P/N: 9F6B1-96D1.15P;<br />

(Riser Rated, 62.5/125µm Multimode, 96 count, 8 subunits,<br />

12 fibers/sub-unit, 1.15km length, premium grade)<br />

COMPLIANCE<br />

RISER RATED:<br />

• ANSI/TIA/EIA-568-A<br />

• ISO/IEC 11801<br />

• Communications Type OFNR (UL) and<br />

CSA FT4 c(UL)<br />

APPLICATIONS<br />

• Intrabuilding backbones<br />

• Vertical shafts within buildings — Riser<br />

• Dry ducts, conduits<br />

PRODUCT CONSTRUCTION/FEATURES<br />

• Tight Buffer design for easy connectorization<br />

• Flexible, lightweight for ease of installation<br />

• Thermoplastic outer and inner (sub-unit)<br />

jackets<br />

• Aramid yarn strength members<br />

• Dielectric central strength member<br />

• Industry standard color codes for buffers<br />

and sub-units are as follows: blue, orange, green, brown,<br />

slate, white, red, black, yellow, violet, pink and aqua<br />

24 FIBER<br />

48 FIBER<br />

72 FIBER<br />

Fiber cable supplied on wooden reels in lengths per order<br />

4 & 6 FIBER<br />

(6 fiber shown)<br />

12 FIBER 24 FIBER 48 FIBER 72 & 96 FIBER<br />

Note: Illustrations not to scale<br />

<strong>Cable</strong> designs and specifications are<br />

subject to change without notice.<br />

26


DISTRIBUTION<br />

Riser Rated Fiber Optic <strong>Cable</strong><br />

OPTICAL CHARACTERIST<strong>ICS</strong><br />

FIBER<br />

TYPE<br />

50/125<br />

62.5/125<br />

Singlemode<br />

Typical Maximum Minimum Modal Guaranteed<br />

Wavelength Attenuation Attenuation Bandwidth Transmission Distance*<br />

nm (dB/Km) (dB/Km) (MHz-Km) (Meters)<br />

Standard Premium Standard Premium Standard Premium Standard Premium<br />

850 2.6 2.6 3.5 3.0 500 500 550 600<br />

1300 0.6 0.6 1.0 1.0 500 1000 550 600<br />

850 2.9 2.9 3.5 3.5 200 220 275 300<br />

1300 0.9 0.9 1.0 1.0 500 1000 550 550<br />

1310 0.35 0.35 1.0 0.5 N/A N/A N/A N/A<br />

1550 0.25 0.25 1.0 0.5 N/A N/A N/A N/A<br />

PHYSICAL SPECIFICATION<br />

FIBER<br />

COUNT<br />

NOMINAL<br />

CABLE DIAMETER<br />

mm<br />

(in.)<br />

MAXIMUM PULLING TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

MINIMUM BEND RADIUS<br />

Installation<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

4<br />

6<br />

12<br />

24<br />

48<br />

72<br />

96<br />

FIBER<br />

COUNT<br />

5.10<br />

5.72<br />

6.60<br />

13.97<br />

16.26<br />

19.56<br />

22.70<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

(0.201)<br />

(0.225)<br />

(0.260)<br />

(0.550)<br />

(0.640)<br />

(0.770)<br />

(0.894)<br />

1000 (225)<br />

1000 (225)<br />

1425 (325)<br />

2670 (600)<br />

4450 (1000)<br />

5560 (1250)<br />

7340 (1650)<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

290 (65)<br />

290 (165)<br />

500 (112)<br />

600 (135)<br />

1000 (225)<br />

1245 (245)<br />

1670 (375)<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

15 x DIA.<br />

OPERATING<br />

TEMP<br />

(° C)<br />

10 x DIA.<br />

STORAGE<br />

TEMP<br />

(° C)<br />

22 (15)<br />

27 (18)<br />

36.9 (25)<br />

140 (94)<br />

193.5 (130)<br />

300 (202)<br />

430 (289)<br />

FIBER CABLES<br />

4<br />

6<br />

12<br />

24<br />

48<br />

72<br />

96<br />

1485<br />

500<br />

500<br />

1000<br />

1000<br />

1500<br />

1500<br />

1500<br />

1000<br />

-20/70<br />

-40/70<br />

MODE AND FIBER TYPE<br />

CORE SIZE<br />

(MICRONS)<br />

CLADDING SIZE<br />

(MICRONS)<br />

COATING SIZE<br />

(MICRONS)<br />

BUFFER SIZE<br />

(MICRONS)<br />

50/125 M/M<br />

50 ± 3<br />

125 ± 2<br />

62.5/125 M/M<br />

62.5 ± 3<br />

125 ± 2<br />

250 ± 15<br />

900 ± 50<br />

Singlemode<br />

8.3 ± 1<br />

125 ± 1<br />

*The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z.<br />

Contact your local sales representative for cable<br />

availability, and delivery lead time.<br />

27


DISTRIBUTION<br />

Plenum Rated Fiber Optic <strong>Cable</strong><br />

PART NUMBER & DESCRIPTION:<br />

PART NUMBER<br />

Fiber<br />

Count<br />

# Of Sub-Units<br />

(Fibers/<br />

Sub-Unit)<br />

9F(X)B2-6B(XXXX) 6 Single Unit<br />

9F(X)B2-12D(XXXX) 12 Single Unit<br />

9F(X)B2-24B(XXXX) 24 4 (6)<br />

9F(X)B2-48D(XXXX) 48 4 (12)<br />

6 FIBER<br />

12 FIBER<br />

FIBER CABLES<br />

Use “X” to specify mode:<br />

5 = 50/125µm Multimode<br />

6 = 62.5/125µm Multimode<br />

8 = Singlemode<br />

Use “XXXX” to specify length in kilometers, four<br />

characters including a decimal point<br />

The last “X” is to be a zero (0) or five (5) only<br />

Add “P” to end of P/N for premium grade performance<br />

Example P/N: 9F6B2-48D1.15P;<br />

(Plenum Rated, 62.5/125µm Multimode, 48 count, 4 subunits,<br />

12 fibers/sub-unit, 1.15km length, premium grade)<br />

COMPLIANCE<br />

PLENUM RATED:<br />

• ANSI/TIA/EIA-568-A<br />

• ISO/IEC 11801<br />

• Communications Type OFNP (UL) and<br />

CSA FT6 c(UL)<br />

APPLICATIONS<br />

• Intrabuilding backbones<br />

• Horizontal/Overhead cabling<br />

• Dry ducts, conduits<br />

PRODUCT CONSTRUCTION/FEATURES<br />

• Tight Buffer design for easy connectorization<br />

• Flexible, lightweight for ease of installation<br />

• Thermoplastic outer and inner (sub unit)<br />

jackets<br />

• Aramid yarn strength members<br />

• Dielectric central strength member<br />

• Industry standard color codes for buffers and<br />

sub-units are as follows: blue, orange, green, grown, slate,<br />

white, red, black, yellow, violet, pink, and aqua<br />

24 FIBER<br />

48 FIBER<br />

Fiber cable supplied on wooden reels in lengths per order<br />

6 FIBER 12 FIBER 24 FIBER 48 FIBER<br />

Note: Illustrations not to scale<br />

<strong>Cable</strong> designs and specifications are<br />

subject to change without notice.<br />

28


DISTRIBUTION<br />

Plenum Rated Fiber Optic <strong>Cable</strong><br />

OPTICAL CHARACTERIST<strong>ICS</strong><br />

FIBER<br />

TYPE<br />

50/125<br />

62.5/125<br />

Singlemode<br />

Typical Maximum Minimum Modal Guaranteed<br />

Wavelength Attenuation Attenuation Bandwidth Transmission Distance*<br />

nm (dB/Km) (dB/Km) (MHz-Km) (Meters)<br />

Standard Premium Standard Premium Standard Premium Standard Premium<br />

850 2.6 2.6 3.5 3.0 500 500 550 600<br />

1300 0.6 0.6 1.0 1.0 500 1000 550 600<br />

850 2.9 2.9 3.5 3.5 200 220 275 300<br />

1300 0.9 0.9 1.0 1.0 500 1000 550 550<br />

1310 0.35 0.35 1.0 0.5 N/A N/A N/A N/A<br />

1550 0.25 0.25 1.0 0.5 N/A N/A N/A N/A<br />

PHYSICAL SPECIFICATION<br />

FIBER<br />

COUNT<br />

NOMINAL<br />

CABLE DIAMETER<br />

mm<br />

(in.)<br />

MAXIMUM PULLING TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

MINIMUM BEND RADIUS<br />

Installation<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

6<br />

12<br />

24<br />

48<br />

FIBER<br />

COUNT<br />

6<br />

12<br />

24<br />

48<br />

5.21<br />

7.62<br />

13.59<br />

15.04<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

1485<br />

(0.205)<br />

(0.300)<br />

(0.535)<br />

(0.592)<br />

1400 (315)<br />

1400 (315)<br />

2670 (600)<br />

4450 (1000)<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

500<br />

1000<br />

1000<br />

1500<br />

400 (90)<br />

500 (112)<br />

600 (135)<br />

1000 (225)<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

1000<br />

15 x DIA.<br />

OPERATING<br />

TEMP<br />

(° C)<br />

-20/50<br />

10 x DIA.<br />

STORAGE<br />

TEMP<br />

(° C)<br />

-40/70<br />

24 (16)<br />

59.6 (40)<br />

160.8 (108)<br />

198 (133)<br />

FIBER CABLES<br />

MODE AND FIBER TYPE<br />

CORE SIZE<br />

(MICRONS)<br />

CLADDING SIZE<br />

(MICRONS)<br />

COATING SIZE<br />

(MICRONS)<br />

BUFFER SIZE<br />

(MICRONS)<br />

50/125 M/M<br />

50 ± 3<br />

125 ± 2<br />

62.5/125 M/M<br />

62.5 ± 3<br />

125 ± 2<br />

250 ± 15<br />

900 ± 50<br />

Singlemode<br />

8.3 ± 1<br />

125 ± 1<br />

*The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z.<br />

Contact your local sales representative for cable<br />

availability, and delivery lead time.<br />

29


DISTRIBUTION<br />

LSOH Rated Fiber Optic <strong>Cable</strong><br />

PART NUMBER & DESCRIPTION:<br />

PART NUMBER<br />

Fiber<br />

Count<br />

# Of Sub-Units<br />

(Fibers/<br />

Sub-Unit)<br />

9F(X)B3-4A(XXXX) 4 Single Unit<br />

9F(X)B3-6B(XXXX) 6 Single Unit<br />

9F(X)B3-8C(XXXX) 8 Single Unit<br />

9F(X)B3-12D(XXXX) 12 Single Unit<br />

9F(X)B3-16A(XXXX) 16 4 (4)<br />

9F(X)B3-24A(XXXX) 24 6 (4)<br />

9F(X)B3-48C(XXXX) 48 6 (8)<br />

9F(X)B3-72D(XXXX) 72 6 (12)<br />

4, 6 & 8 FIBER<br />

16 FIBER<br />

FIBER CABLES<br />

Use “X” to specify mode:<br />

5 = 50/125µm Multimode<br />

6 = 62.5/125µm Multimode<br />

8 = Singlemode<br />

Use “XXXX” to specify length in kilometers, four<br />

characters including a decimal point<br />

The last “X” is to be a zero (0) or five (5) only<br />

Add “P” to end of P/N for premium grade performance<br />

Example P/N: 9F6B3-72D1.15P;<br />

(LSOH Rated, 62.5/125µm Multimode, 72 count, 6 subunits,<br />

12 fibers/sub-unit, 1.15km length, premium grade)<br />

COMPLIANCE<br />

LSOH RATED:<br />

• Low smoke zero halogen<br />

• IEC 754<br />

• VW-1, IEC 1034<br />

• ISO/IEC 11801<br />

• ANSI/TIA/EIA-568-A<br />

APPLICATIONS<br />

• Intrabuilding backbones<br />

• Dry ducts, conduits<br />

PRODUCT CONSTRUCTION/FEATURES<br />

• Tight Buffer design for easy connectorization<br />

• Flexible, lightweight for ease of installation<br />

• Thermoplastic outer and inner (sub-unit)<br />

jackets<br />

• Aramid yarn strength members<br />

• Dielectric central strength member<br />

• Industry standard color codes for buffers and<br />

sub-units are as follows: blue, orange, green, brown, slate,<br />

white, red, black, yellow, violet, pink and aqua<br />

24 FIBER<br />

48 FIBER<br />

72 FIBER<br />

Fiber cable supplied on wooden reels in lengths per order<br />

4, 6 & 8 FIBER<br />

(6 fiber shown)<br />

16 FIBER 24 FIBER 48 FIBER 72 FIBER<br />

Note: Illustrations not to scale<br />

<strong>Cable</strong> designs and specifications are<br />

subject to change without notice.<br />

30


DISTRIBUTION<br />

LSOH Rated Fiber Optic <strong>Cable</strong><br />

OPTICAL CHARACTERIST<strong>ICS</strong><br />

FIBER<br />

TYPE<br />

50/125<br />

62.5/125<br />

Singlemode<br />

Typical Maximum Minimum Modal Guaranteed<br />

Wavelength Attenuation Attenuation Bandwidth Transmission Distance*<br />

nm (dB/Km) (dB/Km) (MHz-Km) (Meters)<br />

Standard Premium Standard Premium Standard Premium Standard Premium<br />

850 2.6 2.6 3.5 3.0 500 500 550 600<br />

1300 0.6 0.6 1.0 1.0 500 1000 550 600<br />

850 2.9 2.9 3.5 3.5 200 220 275 300<br />

1300 0.9 0.9 1.0 1.0 500 1000 550 550<br />

1310 0.35 0.35 1.0 0.5 N/A N/A N/A N/A<br />

1550 0.25 0.25 1.0 0.5 N/A N/A N/A N/A<br />

PHYSICAL SPECIFICATION<br />

FIBER<br />

COUNT<br />

NOMINAL<br />

CABLE DIAMETER<br />

mm<br />

(in.)<br />

MAXIMUM PULLING TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

MINIMUM BEND RADIUS<br />

Installation<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

4<br />

6<br />

8<br />

12<br />

16<br />

24<br />

48<br />

72<br />

FIBER<br />

COUNT<br />

5.36<br />

5.72<br />

5.97<br />

6.60<br />

12.50<br />

14.91<br />

17.09<br />

19.56<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

(0.211)<br />

(0.225)<br />

(0.235)<br />

(0.260)<br />

(0.492)<br />

(0.587)<br />

(0.673)<br />

(0.770)<br />

1000 (225)<br />

1000 (225)<br />

1090 (245)<br />

1425 (320)<br />

2670 (600)<br />

4450 (1000)<br />

4450 (1000)<br />

5500 (1236)<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

290 (65)<br />

290 (65)<br />

310 (70)<br />

500 (112)<br />

600 (135)<br />

1000 (225)<br />

1000 (225)<br />

1245 (280)<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

15 x DIA.<br />

OPERATING<br />

TEMP<br />

(° C)<br />

10 x DIA.<br />

STORAGE<br />

TEMP<br />

(° C)<br />

22 (15)<br />

23.8 (16)<br />

33 (22)<br />

36 (24)<br />

116 (78)<br />

156 (105)<br />

211 (142)<br />

315 (206)<br />

FIBER CABLES<br />

4<br />

6<br />

8<br />

12<br />

16<br />

24<br />

48<br />

72<br />

1485<br />

500<br />

500<br />

500<br />

1000<br />

1500<br />

1500<br />

1500<br />

1500<br />

1000<br />

-20/50<br />

-40/70<br />

*The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z.<br />

For Mode and Fiber Type chart, see page 27.<br />

Contact your local sales representative for cable<br />

availability, and delivery lead time.<br />

31


INTERCONNECT CABLE<br />

Simplex and Duplex Zipcord Fiber Optic <strong>Cable</strong><br />

PART NUMBER & DESCRIPTION:<br />

PART NUMBER<br />

Fiber<br />

Count<br />

# Of Sub-Units<br />

(Fibers/<br />

Sub-Unit)<br />

SIMPLEX<br />

9F(X)C(X)-1E(XXXX) 1 1 (1)<br />

9F(X)C(X)-2E(XXXX) 2 2 (1)<br />

FIBER CABLES<br />

Use first “X” to specify fiber type:<br />

5 = 50/125µm Multimode<br />

6 = 62.5/125µm Multimode<br />

8 = Singlemode<br />

Use second “X” to specify cable material rating:<br />

1 = riser<br />

2 = plenum<br />

3 = low smoke/zero halogen (LS0H)<br />

Use “XXXX” to specify length in kilometers,<br />

four characters including a decimal point<br />

The last “X” is to be a zero (0) or five (5) only<br />

Add “P” to end of P/N for premium grade performance<br />

Example P/N: 9F6C1-2E1.15P;<br />

(Riser Rated, 62.5/125µm Multimode, Duplex <strong>Cable</strong>, 2<br />

sub- units, 1 fiber/sub-unit, 1.15km length, premium grade)<br />

COMPLIANCE<br />

RISER RATED:<br />

• ANSI/TIA/EIA-568-A<br />

• ISO/IEC 11801<br />

• Communications Type OFNR (UL) and<br />

CSA FT4 c(UL)<br />

PLENUM RATED:<br />

• ANSI/TIA/EIA-568-A<br />

• ISO/IEC 11801<br />

• Communications Type OFNP (UL) and<br />

CSA FT6 c(UL)<br />

LS0H RATED:<br />

• IEC 754<br />

• VW-1, IEC 1034<br />

• ISO/IEC 11801<br />

APPLICATIONS<br />

• Fiber to the desk<br />

• Connection to transmission equipment<br />

• Closet jumper assemblies<br />

• Patch panel jumper assemblies<br />

PRODUCT CONSTRUCTION/FEATURES<br />

• Flexible resilient jacket<br />

• Aramid yarn strength members<br />

• Flexible tight buffer for easy connectorization<br />

DUPLEX<br />

Fiber cable supplied on wooden reels in lengths per order<br />

X<br />

Y<br />

SIMPLEX<br />

DUPLEX<br />

Note: Illustrations not to scale<br />

<strong>Cable</strong> designs and specifications are<br />

subject to change without notice.<br />

32


INTERCONNECT CABLE<br />

Simplex and Duplex Zipcord Fiber Optic <strong>Cable</strong><br />

OPTICAL CHARACTERIST<strong>ICS</strong><br />

FIBER<br />

TYPE<br />

Typical Maximum Minimum Modal Guaranteed<br />

Wavelength Attenuation Attenuation Bandwidth Transmission Distance*<br />

nm (dB/Km) (dB/Km) (MHz-Km) Meters<br />

Standard Premium Standard Premium Standard Premium Standard Premium<br />

50/125<br />

62.5/125<br />

Singlemode<br />

850 2.6 2.6 3.5 3.0 500 500 550 600<br />

1300 0.6 0.6 1.0 1.0 500 1000 550 600<br />

850 2.9 2.9 3.5 3.5 200 220 275 300<br />

1300 0.9 0.9 1.0 1.0 500 1000 550 550<br />

1310 0.35 0.35 1.0 0.5 N/A N/A N/A N/A<br />

1550 0.25 0.25 1.0 0.5 N/A N/A N/A N/A<br />

PHYSICAL SPECIFICATION — SIMPLEX<br />

RATING<br />

NOMINAL<br />

CABLE DIAMETER<br />

mm<br />

(in.)<br />

MAXIMUM PULLING TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

MINIMUM BEND RADIUS<br />

(mm)<br />

Installation<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

RISER<br />

PLENUM<br />

LSOH<br />

3.05<br />

(0.120)<br />

400 (90)<br />

133 (30)<br />

50<br />

25<br />

8.3 (5.6)<br />

9.7 (6.5)<br />

9.7 (6.5)<br />

RATING<br />

RISER<br />

PLENUM<br />

LSOH<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

750<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

1000<br />

PHYSICAL SPECIFICATION — DUPLEX<br />

RATING<br />

NOMINAL<br />

CABLE<br />

DIAMETER (MM)<br />

“X”<br />

“Y”<br />

NOMINAL<br />

CABLE<br />

DIAMETER (IN.)<br />

“X”<br />

“Y”<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

1000<br />

OPERATING<br />

TEMP<br />

(° C)<br />

-20/70<br />

-20/50<br />

-20/70<br />

MAXIMUM PULLING<br />

TENSION<br />

NEWTONS (POUNDS)<br />

Installation<br />

Long Term<br />

Installation<br />

STORAGE<br />

TEMP<br />

(° C)<br />

-40/70<br />

MINIMUM BEND RADIUS<br />

(mm)<br />

Long Term<br />

NET WEIGHT<br />

(MAX)<br />

KG/Km<br />

(LBS/1000 FT.)<br />

FIBER CABLES<br />

RISER<br />

PLENUM<br />

LSOH<br />

2.97<br />

6.20<br />

0.117<br />

0.244<br />

400 (90) 133 (30)<br />

50<br />

25<br />

17.4 (11.7)<br />

RATING<br />

MIN. CRUSH<br />

RESISTANCE<br />

(N/CM)<br />

MIN.<br />

IMPACT<br />

CYCLES<br />

MIN. FLEX<br />

RESISTANCE<br />

CYCLES<br />

OPERATING<br />

TEMP<br />

(° C)<br />

STORAGE<br />

TEMP<br />

(° C)<br />

RISER<br />

PLENUM<br />

LSOH<br />

750<br />

1000<br />

1000<br />

-20/70<br />

-20/50<br />

-20/70<br />

-40/70<br />

*The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z.<br />

For Mode and Fiber Type chart see page 27.<br />

Contact your local sales representative for cable<br />

availability, and delivery lead time.<br />

33


APPLICATION INFORMATION<br />

Horizontal Cabling System Structure<br />

The horizontal cabling system extends from the telecommunications outlet in the work area to the horizontal cross-connect in the<br />

telecommunications closet. It includes the telecommunications outlet, an optional consolidation point or transition point connector, horizontal cable,<br />

and the mechanical terminations and patch cords (or jumpers) that comprise the horizontal cross-connect.<br />

APPLICATION<br />

Notes:<br />

* An allowance of 10m (33 ft.) has been<br />

provided for the combined length of<br />

patchcords/cross-connect jumpers and<br />

equipment cables/cords in the HC,<br />

including the WA equipment cords.<br />

* In ISO/IEC 11801, the equivalent<br />

cabling element to the horizontal crossconnect<br />

(HC) is called the floor<br />

distributor (FD).<br />

Customer Premises Equipment<br />

HC Equipment Cord<br />

Patchcords/cross-connect jumpers used in the HC, including<br />

equipment cables/cords, should not exceed 6m (20 ft.)<br />

Note: ISO/IEC 11801 specifies a max. patchcord/cross-connect length<br />

of 5m (16.4 ft.), which does not include equipment cables/cords.<br />

Horizontal cable 90m (295 ft.) max. total<br />

TP or CP (optional)<br />

Telecommunications outlet/connector (TO)<br />

WA Equipment cord<br />

Note: An allowance is made for WA equipment cords of 3m (9.8 ft.)<br />

Some points specified for the horizontal cabling subsystem include:<br />

• Recognized Horizontal <strong>Cable</strong>s:<br />

4-pair 100 Ω unshielded twisted-pair<br />

2-fiber (duplex) 62.5/125 µm or multimode<br />

optical fiber (note: 50/125 µm multimode<br />

fiber will be allowed in ‘568-B)<br />

2-pair 150 Ω STP-A<br />

Note: In addition, two alternate horizontal cabling types allowed by<br />

ISO/IEC 11801 are 120 Ω unshielded twisted-pair and 50/125 µm<br />

multimode optical fiber.<br />

• Multi-pair and multi-unit cables are allowed, provided that they<br />

satisfy the hybrid/bundled cable requirements of TIA/EIA-568-A-3<br />

(see page 13.15).<br />

• A minimum of two telecommunications outlets<br />

are required for each individual work area.<br />

First outlet: 100 Ω twisted-pair<br />

Second outlet: 100 Ω twisted-pair, or 150 Ω<br />

STP-A, or 62.5/125 µm multimode fiber.<br />

• 50 Ω coax cabling is recognized by ‘568-A but is not recommended<br />

for new cabling installations.<br />

• Additional outlets may be provided. These outlets are in addition to<br />

and may not replace the minimum requirements of the standard.<br />

• Bridged taps and splices are not allowed for copper-based horizontal<br />

cabling. (Splices are allowed for fiber.)<br />

Note: In ISO/IEC 11801, the equivalent cabling element to the<br />

horizontal cross-connect (HC) is called the floor distributor (FD).<br />

Topology<br />

The horizontal cabling shall be configured in a star topology; each work area outlet is<br />

connected to a horizontal cross-connect (HC) in a telecommunications closet (TC).<br />

34


APPLICATION INFORMATION<br />

Backbone Cabling System Structure<br />

The backbone cabling system provides interconnections between telecommunications closets, equipment rooms, and entrance facilities. It<br />

includes backbone cables, intermediate and main cross-connects, mechanical terminations, and patch cords or jumpers used for backbone-tobackbone<br />

cross-connections. The backbone also extends between buildings in a campus environment.<br />

APPLICATION<br />

TIA Backbone <strong>Cable</strong> Distances (MC to HC)<br />

Singlemode Fiber..............................................3000m (9840 ft.)<br />

62.5/125 µm Multimode Fiber ........................2000m (6560 ft.)<br />

UTP Copper Applications < 5 MHz ..................800m (2625 ft.)<br />

35


DEFINITIONS<br />

ARAMID YARN<br />

Provides tensile strength in the cable and helps to<br />

protect the optical fibers.<br />

ATTENUATION<br />

A reduction in power or amplitude of the transmitted<br />

signal. In cables, it is generally expressed in decibels per<br />

unit length.<br />

ATTENUATION TO CROSSTALK RATIO (ACR)<br />

The difference between attenuation and crosstalk<br />

measured in decibels.<br />

BACKBONE CABLING<br />

<strong>Cable</strong> and connecting hardware that comprise the main<br />

and intermediate cross-connects, as well as cable runs<br />

that extend between telecommunications closets,<br />

equipment rooms and entrance facilities.<br />

BANDWIDTH<br />

The information carrying capacity, expressed in<br />

megahertz (MHz) and typically normalized to kilometer<br />

lengths, MHz-km.<br />

BALANCE<br />

An indication of signal voltage equality and phase polarity<br />

on a conductor pair. Perfect balance occurs when the<br />

signals across a twisted-pair are equal in magnitude and<br />

opposite in phase with respect to ground.<br />

BALANCED SIGNAL TRANSMISSION<br />

Two voltages, equal and opposite in phase with respect<br />

to each other, across the conductors of a twisted-pair<br />

(commonly referred to as tip and ring).<br />

BEND RADIUS, MINIMUM<br />

The smallest radius a fiber or cable can be bent without<br />

increasing attenuation or risk breaking the fiber.<br />

BUFFERED FIBER<br />

A plastic coating extruded directly onto the coated fiber<br />

for abrasion and chemical resistance. Buffered fibers<br />

have a 900 µm diameter.<br />

BUFFER TUBES<br />

Polymer tubes within a loose tube style cable<br />

construction, used to protect the coated fibers and to<br />

contain water blocking gel.<br />

CABLING<br />

A combination of cables, wire, cords and connecting<br />

hardware used in the telecommunications infrastructure.<br />

CENTRAL STRENGTH MEMBER<br />

A center strength element in some fiber cable designs<br />

typically made of glass reinforced polymer which not<br />

only provide strength but anti-buckling characteristics as<br />

well.<br />

CLADDING<br />

The layer of transparent material surrounding the<br />

transmitting core of an optical fiber serving to protect<br />

the core and to retain the light within it.<br />

COATING<br />

A material applied onto a fiber during the drawing<br />

process, serving to protect it from the environment<br />

CORE<br />

The central segment within an optical fiber through<br />

which light is transmitted.<br />

CROSSTALK<br />

Noise or interference caused by electromagnetic<br />

coupling from one signal path to another. Crosstalk<br />

performance is generally expressed in decibels.<br />

DECIBEL (DB)<br />

A standard unit for expressing transmission gain or loss as<br />

derived from a ratio of signal amplitudes or power.<br />

DELAY SKEW<br />

The difference in propagation delay between the fastest<br />

and slowest pair in a cable or cabling system.<br />

DIFFERENTIAL MODE TRANSMISSION<br />

A transmission scheme where voltages appear equal in<br />

magnitude and opposite in phase across a twisted-pair<br />

with respect to ground. May also be referred to as<br />

balanced mode.<br />

DISTRIBUTION CABLE<br />

<strong>Cable</strong> construction consisting of tight buffered fibers;<br />

intended for intrabuilding installations.<br />

ELECTROMAGNETIC COMPATIBILITY (EMC)<br />

The ability of a system to minimize radiated emissions<br />

and maximize immunity from external noise sources.<br />

ELECTROMAGNETIC INTERFERENCE (EMI)<br />

The interference in signal transmission or reception<br />

caused by electromagnetic radiation generated by other<br />

equipment or cabling.<br />

ELECTRONIC INDUSTRIES ALLIANCE (EIA)<br />

An organization that sets standards for interfaces to<br />

ensure compatibility between data communications<br />

equipment and data terminal equipment.<br />

EQUAL LEVEL FAR-END CROSSTALK (ELFEXT)<br />

Crosstalk measured at the opposite end from which the<br />

disturbing signal is transmitted normalized by the<br />

attenuation contribution of the cable or cabling.<br />

FAR-END CROSSTALK (FEXT)<br />

Crosstalk measured at the opposite end from which the<br />

disturbing signal is transmitted.<br />

FIBER<br />

A light-transmitting strand of glass consisting of a core<br />

and cladding.<br />

FIBER OPTIC TRANSMISSION<br />

A communications scheme whereby electrical data is<br />

converted to light energy and transmitted through optical<br />

fibers.<br />

FOIL TWISTED PAIR (FTP)<br />

<strong>Cable</strong> containing multiple pairs of copper wire enclosed<br />

in a sheath of aluminum foil. It is used in wiring systems<br />

in buildings or other environments where heavy noise<br />

adjacent to the wire might cause interference. The foil<br />

provides insulation not afforded by UTP. The<br />

disadvantage of FTP is that is requires somewhat more<br />

care in grounding than UTP and electrical impedances<br />

must be matched when connecting to UTP. FTP is<br />

typically used in a factory setting.<br />

GRADED INDEX<br />

The core of an optical fiber whereby the refractive index<br />

gradually decreases as it approaches the cladding. This<br />

serves to reduce modal dispersion and to increase<br />

bandwidth potential.<br />

HERTZ (HZ)<br />

A measure of frequency as defined in units of cycles per<br />

second.<br />

HOME-RUN CABLING<br />

A distribution method in which individual cables are run<br />

directly from the horizontal cross-connect to each<br />

telecommunications outlet.This configuration is also<br />

known as star topology.<br />

36


DEFINITIONS<br />

HORIZONTAL CABLING<br />

The cabling between and including the<br />

telecommunications outlet and the horizontal crossconnect.<br />

LONGITUDINAL CONVERSION LOSS (LCL)<br />

A measure (in dB) of the differential voltage induced on a<br />

conductor pair as a result of subjecting that pair to<br />

longitudinal voltage. LCL is considered to be a measure<br />

of circuit balance.<br />

LOOSE TUBE CABLE<br />

An outdoor cable design featuring buffer tubes<br />

containing coated fibers. The tubes act to isolate the<br />

coated fibers from stress. The tubes are also filled with<br />

water blocking gel to prevent axial water migration<br />

within the cable.<br />

MICRON<br />

One millionth of a meter (40 millionths of an inch).<br />

MODULAR DISPERSION<br />

The spreading of an optical pulse caused by different<br />

transit lengths of different propagating modes in a<br />

multimode optical fiber.<br />

MULTIMEDIA<br />

1) An application that communicates to more than one of<br />

the human sensory receptors.<br />

2) Applications that communicate information by more<br />

than one means or cabling media.<br />

MULTIMODE OPTICAL FIBER<br />

An optical fiber that will allow many bound modes to<br />

propagate. The fiber is typically a graded-index fiber.<br />

Multimode optical fibers have a much larger core than<br />

single-mode fibers. See also Optical Fiber <strong>Cable</strong>.<br />

NANOMETER (nm)<br />

One billionth of a meter. Typically used to measure the<br />

wavelength of light.<br />

NANOSECOND (NS)<br />

One billionth of a second.<br />

NEAR-END CROSSTALK (NEXT)<br />

Crosstalk measured at the end from which the disturbing<br />

signal is transmitted.<br />

NUMERICAL APERTURE (NA)<br />

The light acceptance angle of an optical fiber.<br />

PATCH PANEL<br />

Connecting hardware that typically provides means to<br />

connect horizontal or backbone cables to an<br />

arrangement of fixed connectors that may be accessed<br />

using patch cords or equipment cords to form crossconnections<br />

or interconnections.<br />

PATHWAY<br />

A facility (i.e., conduit) for the placement and protection<br />

of telecommunications cables. Same as raceway or<br />

ducting.<br />

PIMF<br />

Pairs in metal foil<br />

PLENUM<br />

A compartment or chamber to which one or more air<br />

ducts are connected and that forms part of the air<br />

distribution system. (Source National Electric Code).<br />

PLENUM RATED CABLE<br />

<strong>Cable</strong>s designed for installation within the air handing<br />

ductwork of buildings, these cables are constructed of<br />

fire retardant materials and generate little smoke.<br />

PROPAGATION DELAY<br />

The amount of time that passes between when a signal is<br />

transmitted and when it is received at the opposite end<br />

of a cable or cabling.<br />

REFRACTIVE INDEX<br />

The ratio of the speed of light in a vacuum to the speed<br />

of light in a particular medium.<br />

RETURN LOSS — COPPER<br />

Noise or interference caused by impedance<br />

discontinuities along the transmission line at various<br />

frequencies. Return loss is expressed in decibels.<br />

RETURN LOSS — FIBER<br />

The ratio of the reflected power to the incident power,<br />

expressed in dB (the amount of light reflected back to<br />

the source at an optical interface).<br />

RISER RATED CABLE<br />

<strong>Cable</strong>s designed for installation within the vertical<br />

pathways between floors in a building.<br />

SCREENED TWISTED-PAIR (ScTP)<br />

A balanced twisted-pair cable surrounded by metallic<br />

braid, foil (screen) or both and bound in a single cable<br />

sheath.<br />

SHIELDED TWISTED-PAIR (STP-A)<br />

A cable surrounded by a metallic braid, foil or both and<br />

bound in a single plastic sheath containing balanced<br />

twisted-pair conductors that are individually shielded.<br />

SINGLEMODE OPTICAL FIBER<br />

An optical fiber that will allow only one mode to<br />

propagate. Fiber core size is typically 8.3 microns.<br />

TELECOMMUNICATIONS<br />

Any transmission, emission, or reception of signs, signals,<br />

writings, images, sounds or information of any nature by<br />

cable, radio, visual, optical or other electromagnetic<br />

systems.<br />

TELECOMMUNICATIONS INDUSTRY ASSOCIATION<br />

(TIA)<br />

An organization that sets standards for cabling, pathways,<br />

spaces, grounding, bonding, administration, field testing<br />

and other aspects of the telecommunications industry.<br />

TRANSFER IMPEDANCE<br />

A measure (in Ω) of shield effectiveness.<br />

TWISTED-PAIR PHYSICAL MEDIA DEPENDENT (TP-<br />

PMD)<br />

Technology under review by the ANSI X3T9.5 working<br />

group that allows 100 Mb/s transmission over twistedpair<br />

cable. Also referred to as CDDI or TPDDI.<br />

UNSHIELDED TWISTED-PAIR (UTP)<br />

A cable with multiple pairs of twisted insulated copper<br />

conductors bound in a single sheath.<br />

WAVELENGTH<br />

The distance between the peaks of an optical waveform;<br />

measured in nanometers.<br />

WORK AREA CABLE<br />

A cable assembly used to connect equipment to the<br />

telecommunications outlet in the work area.Work area<br />

cables are considered to be outside the scope of cabling<br />

standards.<br />

37


ACRONYMS & ABBREVIATIONS<br />

ACR<br />

ANSI<br />

ATM<br />

AWG<br />

BD<br />

BFOC<br />

CD<br />

CDDI ®<br />

CP<br />

CPE<br />

CSA<br />

dB<br />

EF<br />

EIA<br />

ELFEXT<br />

EMC<br />

EMI<br />

EMR<br />

ER<br />

FCC<br />

FD<br />

FDDI ®<br />

ft.<br />

FEXT<br />

FTP<br />

HC<br />

HVAC<br />

Hz<br />

IC<br />

IDC<br />

IEC<br />

IEEE<br />

ISDN<br />

ISO<br />

KTS<br />

LAN<br />

lbf<br />

Attenuation-to-crosstalk ratio<br />

American National Standards Institute<br />

Asynchronous transfer mode<br />

American wire gauge<br />

Building distributor<br />

Bayonet Fiber Optic Connector ST)<br />

Campus distributor<br />

Copper Distributed Data Interface<br />

Consolidation point<br />

Customer premises equipment<br />

Canadian Standards Association<br />

Decibel<br />

Entrance facility<br />

Electronic Industries Association<br />

Equal level far-end crosstalk<br />

Electromagnetic compatibility<br />

Electromagnetic interference<br />

Electromagnetic radiation<br />

Equipment room<br />

Federal Communications Commission<br />

Floor distributor<br />

Fiber Distributed Data Interface<br />

Feet<br />

Far-end crosstalk<br />

Foil twisted-pair<br />

Horizontal cross-connect<br />

Heating, ventilation and air conditioning<br />

Hertz<br />

Intermediate cross-connect<br />

Insulation displacement connection<br />

International Electrotechnical Commission<br />

Institute of Electrical and Electronic Engineers<br />

Integrated Services Digital Network<br />

International Standards Organization<br />

Key telephone system<br />

Local area network<br />

Pounds force<br />

lx<br />

Lux<br />

LEC Local exchange carrier<br />

LED Light emitting diode<br />

LS0H Low smoke zero halogen<br />

m<br />

Meter<br />

Mb/s Megabits per second<br />

MHz Megahertz<br />

mm Millimeter<br />

MC Main cross-connect<br />

NA Numerical Aperture<br />

NEMA National Electrical Manufacturers Association<br />

NEXT Near-end crosstalk<br />

NFPA National Fire Protection Association<br />

nm Nanometer<br />

Ω<br />

Ohm<br />

PBX Private branch exchange<br />

PVC Polyvinyl chloride<br />

RF Radio frequency<br />

RMS Rack mount space<br />

SC Subscriber connector<br />

ScTP Screened twisted-pair<br />

STP-A Shielded twisted-pair<br />

TC Telecommunications closet<br />

TIA Telecommunications Industry Association<br />

TO Telecommunications outlet<br />

TP Transition point<br />

TP-PMD Twisted-pair physical media dependent<br />

TPDDI ® Twisted-pair Distributed Data Interface<br />

TSB Telecommunications System Bulletin<br />

(TSB40-A) and (TSB-67)<br />

UL Underwriters Laboratories<br />

UPS Uninterruptible power supply<br />

UTP Unshielded twisted-pair<br />

Vrms Volts root mean square<br />

WA Work area<br />

X<br />

Cross-connect<br />

µm Micron or micrometer<br />