VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
VCR <strong>Metal</strong> <strong>Gasket</strong> <strong>Face</strong> <strong>Seal</strong> <strong>Fittings</strong> 11<br />
Bodies<br />
Coupling<br />
Leak test<br />
port<br />
A<br />
F flat<br />
VCR<br />
Size<br />
Ordering<br />
Number<br />
Dimensions<br />
A<br />
Dimensions, in. (mm)<br />
1/8 SS-2-VCR-CG 0.66 (16.8) 7/16<br />
1/4 SS-4-VCR-CG 1.19 (30.2) 3/4<br />
1/2 SS-8-VCR-CG 1.31 (33.3) 1 1/16<br />
3/4 SS-12-VCR-CG 1.68 (42.7) 1 1/2<br />
1 SS-16-VCR-CG 2.04 (51.8) 1 3/4<br />
F<br />
Female Reducing Union ➀<br />
Leak test<br />
ports<br />
F flat<br />
VCR<br />
Size<br />
VCR<br />
Size<br />
Ordering<br />
Number<br />
Dimensions<br />
Working Pressure<br />
A E F Y Ni SS Cu<br />
Y<br />
A<br />
E<br />
Dimensions, in. (mm)<br />
1/4 1/8 SS-4-VCR-6-DF-2<br />
1.16<br />
(29.5)<br />
1/2 1/4 SS-8-VCR-6-DF-4<br />
1.41<br />
(35.8)<br />
0.13<br />
(3.3)<br />
0.25<br />
(6.4)<br />
3/4<br />
1 1/16<br />
0.36<br />
(9.1)<br />
0.35<br />
(8.9)<br />
8000<br />
(551)<br />
3500<br />
(<strong>24</strong>1)<br />
psig (bar)<br />
10 000<br />
(689)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
2800<br />
(192)<br />
➀ VCR components with fixed threads must remain stationary during normal installation. These fitting<br />
connections should be assembled only to glands with rotating male or female threaded nuts.<br />
Reducing Adapter ➀<br />
Leak test<br />
port<br />
A<br />
F flat<br />
Y<br />
E<br />
VCR<br />
Size<br />
VCR<br />
Size<br />
Ordering<br />
Dimensions<br />
Working Pressure<br />
Number<br />
A E F Y Ni SS Cu<br />
Dimensions, in. (mm)<br />
psig (bar)<br />
1.19<br />
1/8 1/4 SS-2-VCR-7-4VCRF➁<br />
(30.2)<br />
1.41<br />
1/4 1/2 SS-4-VCR-7-8VCRF<br />
(35.8)<br />
0.09<br />
(2.3)<br />
0.18<br />
(4.6)<br />
3/4<br />
1 1/16<br />
0.69<br />
(17.5)<br />
0.85<br />
(21.6)<br />
8000<br />
(551)<br />
3500<br />
(<strong>24</strong>1)<br />
10 000<br />
(689)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
2800<br />
(192)<br />
➀ VCR components with fixed threads must remain stationary during normal installation. These fitting<br />
connections should be assembled only to glands with rotating male or female threaded nuts.<br />
➁ Not designed for gasket retainer assembly.<br />
Reducing Bushing ➀<br />
Leak test port<br />
E<br />
F flat<br />
VCR<br />
Size<br />
VCR<br />
Size<br />
Ordering<br />
Number<br />
Dimensions<br />
Working Pressure<br />
A E F Y Ni SS Cu<br />
Y<br />
A<br />
Dimensions, in. (mm)<br />
1/4 1/8 SS-4-VCR-7-2VCRF<br />
1.06<br />
(26.9)<br />
1/2 1/4 SS-8-VCR-7-4VCRF<br />
1.41<br />
(35.8)<br />
0.13<br />
(3.3)<br />
0.25<br />
(6.4)<br />
5/8<br />
15/16<br />
0.76<br />
(19.3)<br />
0.91<br />
(23.1)<br />
8000<br />
(551)<br />
3500<br />
(<strong>24</strong>1)<br />
psig (bar)<br />
10 000<br />
(689)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
2800<br />
(192)<br />
➀ VCR components with fixed threads must remain stationary during normal installation. These fitting<br />
connections should be assembled only to glands with rotating male or female threaded nuts.<br />
Male NPT Elbow ➀<br />
E<br />
B<br />
F flat<br />
C<br />
D<br />
NPT<br />
Size<br />
VCR<br />
Size<br />
1/8 1/4 SS-4-VCR-2-2<br />
1/4 1/4 SS-4-VCR-2-4<br />
3/8 1/2 SS-8-VCR-2-6<br />
1/2 1/2 SS-8-VCR-2-8<br />
Ordering<br />
Dimensions<br />
Working Pressure<br />
Number B C D E F Ni SS Cu<br />
Dimensions, in. (mm)<br />
psig (bar)<br />
1.07<br />
(27.2)<br />
1.07<br />
(27.2)<br />
1.45<br />
(36.8)<br />
1.45<br />
(36.8)<br />
0.87<br />
(22.1)<br />
1.05<br />
(26.7)<br />
1.26<br />
(32.0)<br />
1.45<br />
(36.8)<br />
0.38<br />
(9.6)<br />
0.56<br />
(14.2)<br />
0.56<br />
(14.2)<br />
0.75<br />
(19.1)<br />
0.18<br />
(4.6)<br />
0.18<br />
(4.6)<br />
0.40<br />
(10.2)<br />
0.40<br />
(10.2)<br />
1/2<br />
1/2<br />
13/16<br />
13/16<br />
8000<br />
(551)<br />
8000<br />
(551)<br />
3500<br />
(<strong>24</strong>1)<br />
3500<br />
(<strong>24</strong>1)<br />
10 000<br />
(689)<br />
8000<br />
(551)<br />
4300<br />
(296)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
8000<br />
(551)<br />
2800<br />
(192)<br />
2800<br />
(192)<br />
➀ VCR components with fixed threads must remain stationary during normal installation. These fitting<br />
connections should be assembled only to glands with rotating male or female threaded nuts.