VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
VCR® Metal Gasket Face Seal Fittings, (MS-01-24, R8)
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
VCR <strong>Metal</strong> <strong>Gasket</strong> <strong>Face</strong> <strong>Seal</strong> <strong>Fittings</strong> 9<br />
Bodies<br />
E<br />
F flat<br />
A<br />
Female NPT Connector ➀<br />
NPT<br />
Size<br />
VCR<br />
Size<br />
Ordering<br />
Dimensions Working Pressure<br />
Number A E F Ni SS Cu<br />
Dimensions, in. (mm)<br />
psig (bar)<br />
1.10<br />
1/16 1/8 SS-2-VCR-7-1➁<br />
(27.9)<br />
1/8<br />
1.19<br />
1/8 SS-2-VCR-7-2➁<br />
(30.2)<br />
1.41<br />
1/4 SS-4-VCR-7-2<br />
(35.8)<br />
1/4 1/4 SS-4-VCR-7-4<br />
1.54<br />
(39.1)<br />
3/8 1/2 SS-8-VCR-7-6<br />
1.76<br />
(44.7)<br />
1/2 1/2 SS-8-VCR-7-8<br />
1.99<br />
(50.5)<br />
3/4 3/4 SS-12-VCR-7-12<br />
2.36<br />
(59.9)<br />
1 1 SS-16-VCR-7-16<br />
2.51<br />
(63.8)<br />
0.09<br />
(2.3)<br />
0.09<br />
(2.3)<br />
0.18<br />
(4.6)<br />
0.18<br />
(4.6)<br />
0.40<br />
(10.2)<br />
0.40<br />
(10.2)<br />
0.62<br />
(15.7)<br />
0.87<br />
(22.1)<br />
7/16<br />
9/16<br />
5/8<br />
3/4<br />
15/16<br />
1 1/16<br />
1 5/16<br />
1 5/8<br />
6700<br />
(461)<br />
6500<br />
(447)<br />
8000<br />
(551)<br />
6600<br />
(454)<br />
3500<br />
(<strong>24</strong>1)<br />
3500<br />
(<strong>24</strong>1)<br />
3000<br />
(206)<br />
<strong>24</strong>00<br />
(165)<br />
6700<br />
(461)<br />
6500<br />
(447)<br />
8000<br />
(551)<br />
6600<br />
(454)<br />
4300<br />
(296)<br />
4300<br />
(296)<br />
3700<br />
(254)<br />
3000<br />
(206)<br />
6700<br />
(461)<br />
6500<br />
(447)<br />
6400<br />
(440)<br />
5200<br />
(358)<br />
2800<br />
(192)<br />
2800<br />
(192)<br />
<strong>24</strong>00<br />
(165)<br />
1900<br />
(130)<br />
➀ VCR components with fixed threads must remain stationary during installation. These fitting<br />
connections should be assembled only to glands with rotating male or female threaded nuts.<br />
➁ Not designed for gasket retainer assembly.<br />
Swagelok Tube Fitting Connector ➀<br />
E<br />
F flat<br />
A<br />
D<br />
C<br />
G flat<br />
Tube<br />
Size<br />
VCR<br />
Size<br />
1/8 1/4 SS-4-VCR-6-200<br />
1/4 1/4 SS-4-VCR-6-400<br />
3/8 1/2 SS-8-VCR-6-600<br />
1/2 1/2 SS-8-VCR-6-810<br />
Ordering<br />
Dimensions<br />
Working Pressure<br />
Number A C D E F G Ni SS Cu<br />
Dimensions, in. (mm)<br />
psig (bar)<br />
1.53<br />
(38.9)<br />
1.62<br />
(41.1)<br />
1.84<br />
(46.7)<br />
1.95<br />
(49.5)<br />
0.60<br />
(15.2)<br />
0.70<br />
(17.8)<br />
0.76<br />
(19.3)<br />
0.86<br />
(21.8)<br />
0.50<br />
(12.7)<br />
0.60<br />
(15.2)<br />
0.66<br />
(16.8)<br />
0.90<br />
(22.9)<br />
0.09<br />
8000<br />
5/8 7/16<br />
(2.3)➁ (551)<br />
0.18<br />
8000<br />
5/8 9/16<br />
(4.6)<br />
(551)<br />
0.28<br />
(7.1)➁ 15/16 11/16 3500<br />
(<strong>24</strong>1)<br />
0.40<br />
(10.2)<br />
15/16 7/8<br />
3500<br />
(<strong>24</strong>1)<br />
10 000<br />
(689)<br />
10 000<br />
(689)<br />
4300<br />
(296)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
6400<br />
(440)<br />
2800<br />
(192)<br />
2800<br />
(192)<br />
Dimensions A, C, and D are typical finger-tight. Swagelok nuts and ferrules are provided assembled, as shown.<br />
For tubing maximum pressure ratings for use with Swagelok tube fittings, see Swagelok Tubing Data, <strong>MS</strong>-<strong>01</strong>-107.<br />
➀ VCR components with fixed threads must remain stationary during installation. These fitting connections should be<br />
assembled only to glands with rotating male or female threaded nuts.<br />
➁ May contain internal diameter transitions.<br />
F flat<br />
F 1 flat<br />
G flat<br />
Swagelok Tube Fitting Bulkhead Connector ➀<br />
E<br />
A<br />
C<br />
D<br />
Tube<br />
Size<br />
VCR<br />
Size<br />
1/4 1/4<br />
Ordering<br />
Number<br />
SS-4-VCR-A1-400<br />
SS-4-VCR-A1S-400<br />
3/8 1/2 SS-8-VCR-A1-600<br />
1/2 1/2 SS-8-VCR-A1-810<br />
2.25<br />
(57.2)<br />
1.88<br />
(47.8)<br />
Dimensions<br />
A C D E F F 1 G<br />
Dimensions, in. (mm)<br />
1.32<br />
(33.5) 0.60 0.18<br />
1.05 (15.2) (4.6)<br />
5/8 5/8 9/16<br />
(26.7)<br />
2.54<br />
(64.5)<br />
2.74<br />
(69.6)<br />
1.45<br />
(36.8)<br />
1.65<br />
(41.9)<br />
0.66<br />
(16.8)<br />
0.90<br />
(22.9)<br />
0.28<br />
(7.1)<br />
0.40<br />
(10.2)<br />
15/16 3/4 11/16<br />
15/16 15/16 7/8<br />
Panel<br />
Hole Size<br />
Working Pressure<br />
Max Panel<br />
Thickness Ni SS Cu<br />
psig (bar)<br />
Dimensions A, C, and D are typical finger-tight. Swagelok nuts and ferrules are provided assembled, as shown.<br />
For tubing maximum pressure ratings for use with Swagelok tube fittings, see Swagelok Tubing Data, <strong>MS</strong>-<strong>01</strong>-107.<br />
➀ VCR components with fixed threads must remain stationary during installation. These fitting connections should be assembled only to glands with rotating male<br />
or female threaded nuts.<br />
15/32<br />
(11.9)<br />
19/32<br />
(15.0)<br />
25/32<br />
(19.8)<br />
0.40<br />
(10.2)<br />
0.13<br />
(3.3)<br />
0.44<br />
(11.2)<br />
0.50<br />
(12.7)<br />
8000<br />
(551)<br />
8000<br />
(551)<br />
3500<br />
(<strong>24</strong>1)<br />
3500<br />
(<strong>24</strong>1)<br />
10 000<br />
(689)<br />
10 000<br />
(689)<br />
4300<br />
(296)<br />
4300<br />
(296)<br />
6400<br />
(440)<br />
6400<br />
(440)<br />
2800<br />
(192)<br />
2800<br />
(192)