<strong>SOLARWATT</strong> M135-55 GEG LK<br />

The modules manufactured in <strong>Glass</strong>-<strong>Glass</strong> Lamination Technology<br />

have an extremly high mechanical stability and are therefore very<br />

resistant against environmental influences.<br />

monocrystalline solar cell<br />

with 16 - 17% efficiency,<br />

125 x 125 mm<br />

1520<br />

710<br />

<strong>SOLARWATT</strong> AG<br />

Maria-Reiche-Straße 2a<br />

01109 Dresden, Germany<br />

Tel. +49 (0) 3 51 / 88 95-0<br />

Fax +49 (0) 3 51 / 88 95-111<br />

www.solarwatt.de<br />

info@solarwatt.de<br />

Certified acc. to:<br />

DIN EN ISO 9001 and 14001


<strong>SOLARWATT</strong> <strong>Solar</strong> modules M135-55 GEG LK<br />

are noted for:<br />

Efficient, low-loss energy production<br />

Certified materials and quality of workmanship<br />

25 years warranty to power output according to <strong>SOLARWATT</strong>’s Limited Warranty Conditions<br />

Subject to change without notice. 2007/08<br />

Specification<br />

Nominal Power P max<br />

@ STC*<br />

typ. Nominal Voltage U mpp<br />

@ STC*<br />

typ. Nominal Current I mpp<br />

@ STC*<br />

typ. Open Circuit Voltage U OC<br />

@ STC*<br />

typ. Short Circuit Current I SC<br />

@ STC*<br />

Off-load voltage rating<br />

NOCT **<br />

typ. Nominal Power P max<br />

@ NOCT**<br />

typ. Nominal Voltage U mpp<br />

@ NOCT**<br />

typ. Open Circuit Voltage U OC<br />

@ NOCT**<br />

typ. Short Circuit Current I SC<br />

@ NOCT**<br />

Module efficiency reduction at 200 W/m 2 ***<br />

typ. Temperature Coefficient of P N<br />

typ. Temperature Coefficient of U oc<br />

typ. Temperature Coefficient of I SC<br />

Max. System Voltage<br />

IP protection level<br />

Reverse current power rating I R<br />

****<br />

Module Technology<br />

Module Design<br />

No. and Type of <strong>Solar</strong> Cells<br />

Cables<br />

Bypass-Diodes<br />

Dimensions (LxWxH)<br />

Weight<br />

Operating Temperature Range<br />

Ambiente Temperature Range<br />

Mechanical ratings<br />

Qualifications<br />

Measuring tolerances<br />

M135-55 GEG LK<br />

125 W p<br />

130 W p<br />

135 W p<br />

27,3 V 27,4 V 27,5 V<br />

4,63 A 4,81 A 5,01 A<br />

33,7 V 33,7 V 33,8 V<br />

5,02 A 5,28 A 5,49 A<br />

33,7 V 33,7 V 33,8 V<br />

45 ° C<br />

90 W p<br />

94 W p<br />

97 W p<br />

24,1 V 24,2 V 24,3 V<br />

30,5 V 30,5 V 30,6 V<br />

4,04 A 4,25 A 4,42 A<br />

-0,1 % -0,1% -0,0 %<br />

-0,50 %/K<br />

-0,37 %/K<br />

+0,03 %/K<br />

1000 V<br />

IP 65<br />

15 A<br />

<strong>Glass</strong>-<strong>Glass</strong>-Laminate<br />

Cover material: high transparent solar glass (tempered), 4 mm<br />

Encapsulation: EVA-<strong>Solar</strong> Cells -EVA<br />

Back material: tempered float glass, 4 mm<br />

55 monocrystalline solar cells, 125 x 125 mm<br />

connection buttons with 2 x 1 m solar cable, 1 x 4 mm 2 with Tyco plug connectors, casted in the button<br />

3 pieces, casted at the connection buttons<br />

1520 x 710 x 9 mm<br />

25 kg<br />

-40 ... +45 °C<br />

-40 ... +80 °C<br />

suction pressure of 2400 Pa approved (Wind speed 130 km/h with safety factor 3),<br />

load of 5.400 Pa approved<br />

IEC 61215 Ed. 2 in preperation Safety Class II ( IEC 61730 in preparation )<br />

P max<br />

@ STC ± 5%, all other electric parameters ± 10%<br />

This data sheet conforms to DIN EN 50380:2003<br />

* STC: Standard Test Conditions, measurement conditions: Radiation strength 1000 W/m 2 , spectral distribution AM 1.5, temperature 252 °C, in accordance with EN 60904-3<br />

** NOCT: Normal Operation Cell Temperature, measurement conditions: Radiation strength 800 W/m 2 , AM 1.5, temperature 20 °C, wind speed 1m/s, electrical open-circuit operation<br />

*** Reduction in the module efficiency with reduction in radiation strength of 1000 W/m 2 , to 200 W/m 2 , temperature 25 °C, in accordance with EN 60904-1<br />

**** Reverse current power rating: Operation of the modules with an external power source is only permitted with a string fuse with a release current of < 3 x ISC @ NOCT**

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!