Exocet Premium Heating Oil Additives - PEAK OIL
Exocet Premium Heating Oil Additives - PEAK OIL
Exocet Premium Heating Oil Additives - PEAK OIL
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Exocet</strong> <strong>Premium</strong> <strong>Heating</strong> <strong>Oil</strong> <strong>Additives</strong><br />
Description<br />
Liquid, multi-component, premium heating oil additive with extensive field<br />
experience. These additives can be used to upgrade standard <strong>Heating</strong> <strong>Oil</strong> to<br />
premium products and achieve substantial additional margins. They contain a<br />
combination of components to help maintain quality, reduce fuel related service<br />
problems as well as enhancing performance.<br />
The additives are supplied in bottles with 200ml additive present and treat 1000<br />
litres of heating oil (1:5,000 treat rate). They are suitable for batch treatment in<br />
tanks (e.g. bottle dosing and splash blending). It is preferable to empty the<br />
additive into the storage tanks before adding heating oil on top (promotes<br />
mixing), however mixing will occur after a few days if added to an existing full<br />
tank.<br />
Typical <strong>Heating</strong> <strong>Oil</strong> System Problems<br />
Fuel Storage<br />
Pressure Jet Burner<br />
Vent<br />
Fuel Tank<br />
Fill<br />
Tiny Hole<br />
Deposits partially<br />
block nozzle, creating<br />
poor atomisation and<br />
decreasing efficiency<br />
Fuel<br />
High Pressure<br />
High Pressure Fuel <strong>Oil</strong><br />
Fine <strong>Oil</strong> Spray<br />
Water layer<br />
To Boiler<br />
Over time and/or heat<br />
e in fuel lines (e.g. summer) small oxidation<br />
ing flow deposits form in the fuel,<br />
Dirty System<br />
sink to the bottom and stick<br />
together to create sludge<br />
Clean System<br />
Nozzle<br />
Results of F21-61 Stability Test<br />
Results of F21 - 61 Accelerated Stability Test<br />
Low Pressure In<br />
Boiler Furnace<br />
Typical <strong>Heating</strong> <strong>Oil</strong><br />
(Untreated)<br />
<strong>Premium</strong><br />
<strong>Heating</strong> <strong>Oil</strong><br />
ion and pitting of<br />
l lines and tank<br />
Build-up of sludge in fuel lines<br />
and restricting flow<br />
Plugged fuel filters<br />
Dirty System<br />
<strong>Premium</strong> Anti - oxidants system inhibits the growth of deposits<br />
caused by fuel reacting with oxygen in the air.<br />
Clean System<br />
Foxwood Road<br />
Sheepbridge<br />
Chesterfield, S41 9RF<br />
Tel: 01246 450242<br />
www.peakoil.co.uk<br />
sales@peakoil.co.uk
<strong>Exocet</strong> <strong>Premium</strong> <strong>Heating</strong> <strong>Oil</strong> <strong>Additives</strong><br />
Protection Against Copper Degradation<br />
<strong>Premium</strong> Metal<br />
Deactivator is designed to<br />
reduce fuel degradation<br />
caused by the interaction<br />
with metals in the fuel<br />
system<br />
<strong>Heating</strong> <strong>Oil</strong> will darken<br />
and degrade over time,<br />
when in contact with the<br />
copper lines in heating oil<br />
systems<br />
Typical<br />
<strong>Heating</strong> <strong>Oil</strong><br />
(Untreated)<br />
<strong>Premium</strong><br />
<strong>Heating</strong><br />
<strong>Oil</strong><br />
<strong>Premium</strong> <strong>Heating</strong> <strong>Oil</strong><br />
avoids deposit & sludge<br />
Problems that occur in<br />
Boiler systems<br />
I have helped the<br />
environment by using<br />
P romotes a greater system<br />
operating efficiency =<br />
lower fuel consumption<br />
<strong>Premium</strong> <strong>Heating</strong><br />
<strong>Oil</strong><br />
Lower Carbon<br />
Emissions Cycle<br />
Less fuel<br />
Consumed = nearly<br />
nearly half a tonne<br />
less CO 2 emitted per<br />
house every year<br />
<strong>Premium</strong> <strong>Heating</strong> <strong>Oil</strong><br />
Lower CO 2 emissions<br />
means up to 18 fewer<br />
Existing trees can help trees/year are needed to<br />
absorb CO 2 from other sources absorb it<br />
and make our environment<br />
cleaner<br />
Foxwood Road<br />
Sheepbridge<br />
Chesterfield, S41 9RF<br />
Tel: 01246 450242<br />
www.peakoil.co.uk<br />
sales@peakoil.co.uk