Technical data<br />
Type<br />
Make<br />
Explosion protection (ATEX)<br />
K<strong>KE</strong>/B<strong>KE</strong>/L<strong>KE</strong><br />
<strong>Electromach</strong><br />
K<strong>KE</strong>: II 2 GD EEx e II T6/T4 T 80°C...T 130°C<br />
II 2 GD EEx ia/ib II T6 T80°C<br />
B<strong>KE</strong>: II 2 GD EEx e II T6/T4 T 80°C...T 130°C<br />
L<strong>KE</strong>:<br />
II 2 GD EEx e II<br />
Test certificate<br />
Ambient temperature<br />
Degree of protection<br />
K<strong>KE</strong>: <strong>KE</strong>MA 03 ATEX 2139<br />
B<strong>KE</strong>: <strong>KE</strong>MA 03 ATEX 2140<br />
L<strong>KE</strong>: <strong>KE</strong>MA 03 ATEX 2138U<br />
K<strong>KE</strong>/B<strong>KE</strong><br />
Standard: - 20°C… + 40°C (T6...T4)<br />
Special: - 33°C… + 55°C (T5...T4)<br />
L<strong>KE</strong>:<br />
Standard: - 33°C… + 55°C<br />
For gas: IP 66<br />
For dust: IP 6X<br />
According to EN-IEC-60529<br />
Material<br />
Gaskets<br />
Cover<br />
Rated voltage<br />
External ground bolt<br />
Terminals<br />
Earth bar<br />
Mounting lugs<br />
Cable entries<br />
Cable glands<br />
Breather/drain<br />
Stainless steel 316 L, thickness 1,5 mm<br />
Option: Stainless steel 304 or sheet steel epoxy powder<br />
coated<br />
Neoprene<br />
Bolted-on<br />
Max. 11 kV<br />
M6 (max. 35mm²) / AWG 2<br />
Option: 70 mm² / AWG 00<br />
K<strong>KE</strong>: max. 35 mm² / AWG 2<br />
B<strong>KE</strong>: max 240 mm² / 500 mcm<br />
Raised (mounted on studs)<br />
External mounting lugs<br />
Punched holes<br />
EExe certified cable glands can be supplied<br />
When used outdoors, a breather/drain is strongly recommended<br />
to avoid condense water.