AP-4 leaf stomatal resistance measurement instrument, manufacturer: Delta-T (2000)<br />

• Measurements of the resistance (s cm-1) and conductance of leaves stomata (mmol m-2 s-1).<br />

Measurement error: < 2% Measurement t<strong>im</strong>e: 15-60 s<br />

• Sensors: PAR illumination, temperature, pressure; installed on the measurement head.<br />

Examples of use:<br />

• Opt<strong>im</strong>isation of plant growth conditions, e.g. temperature, substrate/soil moisture,<br />

fertilization.<br />

• Stress resistance comparison of plant varieties.<br />

Automated soil CO 2<br />

emission measurement system, manufacturer: ACE (2009)<br />

• CO 2<br />

concentration measurements; range: 0-896 ppm, precision: 1 ppm. Open<br />

system (chamber capacity: 1.0 dm 3 ) – w/o pressure gradient; Closed system<br />

(chamber capacity: 2.6 l). Flow rate: 100-500 ml min -1 , precision: 2%.<br />

• 40 Ah battery operating t<strong>im</strong>e: up to 28 days.<br />

- PAR: 0-3000 μmol m -2 s -1 .<br />

- soil temperature.<br />

Examples of use:<br />

• Continuous monitoring of soil environments, on-site measurements of soil<br />

respiratory activity.<br />

• Impact of anthropogenic factors on the soil CO 2<br />

emissions.<br />

LAI 2200 portable leaf area meter, manufacturer: Li-Cor (2010)<br />

• A device for quick and non-destructive measurement of the leaf area index<br />

(LAI) and other properties of plant areas, e.g. mean tip angle (MTA). The LAI<br />

measurements of grasses and trees can be performed in various weather conditions.<br />

• The sensor operating range is 320-420 nm. Includes adapters for FOV l<strong>im</strong>itation<br />

to 12.3°, 28.6°, 43.4°, 58.1° and 74.1°.<br />

Examples of use:<br />

• Monitoring of plant cover.<br />

• Assessment of pesticides activity.<br />

Helios Gamma spectrophotometer, manufacturer: Thermo Spectronic (2002)<br />

• Single-beam optical system. Wavelength range: 190-1100 nm, aperture spectral width: 2 nm, wavelength precision: