Vervielfält.-Pause<br />

Nr.<br />

Arbeitspause Nr.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

Receiver<br />

Characteristics Condition/Remark Value<br />

Kennwerte Bedingung/Kommentar Wert<br />

Speaker part<br />

Rated Input Nennleistung 0.3 W<br />

Maximum Input Max. Leistung 0.6 W<br />

Impedance Impedanz 1,5 kHz, 1V 8 Ω ± <strong>15</strong>%<br />

Resonance frequency Resonanzfrequenz (fo) 850 Hz ± 20%<br />

Frequency range Frequenzbereich deviation 20 dB max 850Hz…10kHz<br />

Sound pressure level Schalldruckpegel (0.3W, 0.1m) (at 800,1000,1200,<strong>15</strong>00Hz) 90 ± 3dB<br />

Buzzes & rattles Summen & Rasseln Must be normal at sine wave 1,5 Vrms<br />

Receiver part<br />

Rated Input Nennleistung 1 mW<br />

Maximum Input Max. Leistung 60 mW<br />

Rated Impedance Impedanz at 1 kHz, 0.5V 32 Ω ± <strong>15</strong>%<br />

Sound pressure level Schalldruckpegel at 1 kHz, 1 mW 107 ± 3 dB<br />

Total harmonic distortion Klirrfaktor at 1 kHz, 10mW max. 5 %<br />

General characteristics Allgemeine Kennwerte<br />

Operating temperature Arbeitstemperatur - 30 ... + 70°C<br />

Storage temperature Lagertemperatur - 40 ... + 80°C<br />

Weight Gewicht 1.35 g<br />

gezeichnet<br />

bearbeitet<br />

geprüft<br />

normgepr.<br />

Tag Name<br />

17.03.03 Ni<br />

Halbzeug, Werkstoff<br />

Änd. Änd.-Mittlg.<br />

zust. Nr.<br />

Tag Name<br />

Untolerierte Maße<br />

Maßstab<br />

Zeichn.-Nr.<br />

Ersatz f.<br />

Zeichn.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

030317.1R<br />

1<br />

Page Blatt of von 5


Vervielfält.-Pause<br />

Nr.<br />

Arbeitspause Nr.<br />

Drawing Zeichnung<br />

gezeichnet<br />

bearbeitet<br />

geprüft<br />

normgepr.<br />

Tag Name<br />

17.03.03 Ni<br />

Halbzeug, Werkstoff<br />

Änd. Änd.-Mittlg.<br />

zust. Nr.<br />

Tag Name<br />

Untolerierte Maße<br />

Maßstab<br />

Zeichn.-Nr.<br />

030317.1R<br />

Ersatz f.<br />

Zeichn.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

2<br />

Page Blatt of von 5


Vervielfält.-Pause<br />

Nr.<br />

Arbeitspause Nr.<br />

Environmental test Klima Test<br />

Heat Test<br />

Temperature + 85 ± 2°C<br />

Duration 96 hrs<br />

Cold Test<br />

Temperature - 40 ± 2°C<br />

Duration 96 hrs<br />

Moisture Test<br />

Temperature + 40 ± 2°C<br />

Humidity 90 % - 95 % RH<br />

Duration 96 hrs<br />

Temperature Cycles Test<br />

Cycle 100<br />

all these tests above should be measured after leaving normal temperature for 6 hrs.<br />

Vibration Test<br />

Frequency 10 ~ 55 Hz, amplitude 1.5mm vibration in three planes for 2 hours each<br />

Drop Test<br />

Free-drop each side 1.5m on concrete surface with the P.C.B dummy set of 100g<br />

(6 directions, total 3times).<br />

Measurement shall be done after 3 hours of conditioning at 20°C sensitivity difference at 1 kHz shall<br />

be within ± 4 dB from initial value after test.<br />

gezeichnet<br />

bearbeitet<br />

geprüft<br />

normgepr.<br />

Tag Name<br />

29.01.03 Ni<br />

Halbzeug, Werkstoff<br />

Änd. Änd.-Mittlg.<br />

zust. Nr.<br />

Tag Name<br />

Untolerierte Maße<br />

Maßstab<br />

Zeichn.-Nr.<br />

030129.1R<br />

Ersatz f.<br />

Zeichn.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

Page Blatt 3<br />

of von 5


Vervielfält.-Pause<br />

Nr.<br />

Arbeitspause Nr.<br />

Standard earpiece Standard Hörerteil<br />

Design of handset cavity is the key to maximizing the merit of receiver unit. In order to obtain<br />

optimum receiver unit characteristics, the earpiece construction should be as shown below.<br />

Das Design der Hörmuschel ist der Schlüssel zur Maximierung der Empfangseigenschaften. Für<br />

optimale Empfangseigenschaften sollte der Hörmuschelaufbau sein wie unten gezeigt.<br />

Acoustic specification<br />

gezeichnet<br />

bearbeitet<br />

geprüft<br />

normgepr.<br />

Frequency (Hz)<br />

100 110 dB<br />

Tag Name<br />

29.01.03 Ni<br />

Halbzeug, Werkstoff<br />

Änd. Änd.-Mittlg.<br />

zust. Nr.<br />

Tag Name<br />

Untolerierte Maße<br />

Maßstab<br />

Tolerance curve<br />

Upper Lower<br />

200 - 103,5 dB<br />

400 117 dB 107 dB<br />

600 117 dB 107 dB<br />

1000 110 dB 104 dB<br />

2000 105 dB 95 dB<br />

3000 105 dB 85 dB<br />

4000 110 dB -<br />

Zeichn.-Nr.<br />

030129.1R<br />

Ersatz f.<br />

Zeichn.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

-<br />

Page Blatt 4<br />

of von 5


Vervielfält.-Pause<br />

Nr.<br />

Arbeitspause Nr.<br />

Frequency Response curve Frequenzgang<br />

Speaker part<br />

Frequency Response Frequenzgang<br />

Receiver part<br />

gezeichnet<br />

bearbeitet<br />

geprüft<br />

normgepr.<br />

Tag Name<br />

29.01.03 Ni<br />

Halbzeug, Werkstoff<br />

Änd. Änd.-Mittlg.<br />

zust. Nr.<br />

Tag Name<br />

Untolerierte Maße<br />

Maßstab<br />

Zeichn.-Nr.<br />

030129.1R<br />

Ersatz f.<br />

Zeichn.<br />

F-R-W-<strong>15</strong>-<strong>FD</strong><br />

Page Blatt 5<br />

of von 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!