• Specific programs for special applications available on demand - 16 programs<br />

• Temperature and time display<br />

• Automatic water draft<br />

Semi-Automatic Calorimeter<br />

LECO AC600 (2009)<br />

Producer: LECO<br />

Basic parameters:<br />

• Analysis <strong>of</strong> the organic and nonorganic materials, such as solid and liquid fuel,<br />

biomass and food<br />

• Water system with temperature stabilization<br />

• Pressure tube with a fixed or removable electrode<br />

• Automatic filling <strong>of</strong> the calorimetric tube with oxygen<br />

• Automatic discharge <strong>of</strong> gases from the calorimetric tube<br />

• The bomb does not need to be cooled after tests<br />

• Low costs <strong>of</strong> analysis<br />

Liquid Chromatograph Mass Spectrometer<br />

LTQ ORBITRAP VELOS (2009)<br />

Producer: Thermo Scientific<br />

Basic parameters:<br />

• Qualitative and quantitative analysis <strong>of</strong> foodstuffs,<br />

• Mass range m/z 15-200, m/z 50-2000, m/z 200-4000<br />

• Ionization sources – ESI, H-ESI, APCI, APPI<br />

• Resolution min. – 7500, max. >100 000<br />

• Mass analyzers – linear ion trap LTQ, Orbitrap<br />

• MS/MSn mode<br />

Evaporator<br />

Heidolph Hei-VAP Precision (ML) (2009)<br />

Producer: Heidolph<br />

Basic parameters:<br />

• 4.3”Color LCD display<br />

• Motor lift<br />

• Lift speed 30 mm/s<br />

• Hight adjustment 155 mm<br />

• Thermal power 1300 W<br />

• Temperature adjustment between 20⁰C and 210⁰C<br />

• Resolution ± 1 ⁰C<br />

• Volume <strong>of</strong> heating compartment 4.5 l<br />

• Remote control<br />

Dryer<br />

Venticell Comfort (2009)<br />

Producer: MMM Group<br />

Basic parameters:<br />

• 6 programs<br />

• Chip card system for individual program storage<br />

• RS 232 PC or printer interface<br />

• Delayed heating start and stop function<br />

• Acoustic and visual alarm in error state<br />

• Time range 0–16 years with 1 min-intervals<br />

• Digital safety thermostat class 2<br />

• Real time<br />

• Selectable rate <strong>of</strong> temperature increase or decrease - RAMPS<br />

• Programming <strong>of</strong> time segments - SEGMENTS<br />

• Programme cycles<br />

• Manual control <strong>of</strong> the air exhaust flap<br />

7<br />