CUP AT WRONG LOCATION<br />

HIGH/LOW or Y AXIS<br />

Go to Factory Diagnostics.<br />

Check encoder counts. Send<br />

to home, does home switch<br />

light come on?<br />

YES<br />

NO<br />

Is shelf setting correct?<br />

YES<br />

NO<br />

Check, repair,<br />

or replace X<br />

Axis E-chain<br />

Ground wire.<br />

Send cup to “A9”<br />

position. Press “F”<br />

to go home. Did<br />

green light flicker?<br />

YES NO<br />

See XY not<br />

working<br />

page 31<br />

Fire the plunger to ensure<br />

correct location. Repeat<br />

“A-E” cycle two to three<br />

times. Is cup in correct<br />

location?<br />

YES<br />

NO<br />

Do a Keypad<br />

test.<br />

Send cup to “A”<br />

shelf. Is cup in<br />

correct location?<br />

YES NO<br />

Repeat “A-E” cycle two to<br />

three times. Does cup<br />

position get worse?<br />

YES<br />

NO<br />

Close door<br />

and test vend.<br />

Check Harness,<br />

Motor, Board.<br />

Go to Factory Diagnostics<br />

and check “Offset<br />

Adjustment” and adjust as<br />

necessary. See<br />

programming section of<br />

manual.<br />