Glassfront BevMax 3 Vender - The Vending Center
Glassfront BevMax 3 Vender - The Vending Center
Glassfront BevMax 3 Vender - The Vending Center
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
CUP AT WRONG LOCATION<br />
HIGH/LOW or Y AXIS<br />
Go to Factory Diagnostics.<br />
Check encoder counts. Send<br />
to home, does home switch<br />
light come on?<br />
YES<br />
NO<br />
Is shelf setting correct?<br />
YES<br />
NO<br />
Check, repair,<br />
or replace X<br />
Axis E-chain<br />
Ground wire.<br />
Send cup to “A9”<br />
position. Press “F”<br />
to go home. Did<br />
green light flicker?<br />
YES NO<br />
See XY not<br />
working<br />
page 31<br />
Fire the plunger to ensure<br />
correct location. Repeat<br />
“A-E” cycle two to three<br />
times. Is cup in correct<br />
location?<br />
YES<br />
NO<br />
Do a Keypad<br />
test.<br />
Send cup to “A”<br />
shelf. Is cup in<br />
correct location?<br />
YES NO<br />
Repeat “A-E” cycle two to<br />
three times. Does cup<br />
position get worse?<br />
YES<br />
NO<br />
Close door<br />
and test vend.<br />
Check Harness,<br />
Motor, Board.<br />
Go to Factory Diagnostics<br />
and check “Offset<br />
Adjustment” and adjust as<br />
necessary. See<br />
programming section of<br />
manual.<br />
37