14.03.2014 Views

LI-8150 Multiplexer

LI-8150 Multiplexer

LI-8150 Multiplexer

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

For the <strong>LI</strong>-8100 Automated Soil CO 2 Flux System<br />

Automated Solution for Spatial and Temporal Sampling


<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

Weatherproof Case<br />

System<br />

Display<br />

Solenoid<br />

Banks<br />

Chamber<br />

Ports<br />

<strong>LI</strong>-8100 Analyzer<br />

Control Unit<br />

<strong>LI</strong>-8100 Connections<br />

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

Connections<br />

The Multiplexed System<br />

■ Connect up to<br />

16 chambers<br />

■ 30 m diameter<br />

coverage<br />

■ Auxiliary sensor<br />

connections<br />

■ Easy connection to the <strong>LI</strong>-8100<br />

Analyzer Control Unit (ACU)<br />

■ NDIR CO 2 /H 2 O analyzer in the<br />

<strong>LI</strong>-8100 ACU<br />

■ Single gas analyzer prevents<br />

measurement bias


Automated Solution for Spatial and Temporal Sampling<br />

F CO2 (µmol m -2 s -1 )<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

F CO2<br />

Soil Temperature<br />

15<br />

10<br />

5<br />

0<br />

Soil Temperature (°C)<br />

0.2<br />

0.0<br />

48 50 52 54 56 58 60<br />

-5<br />

Day of Year<br />

Time series data for Soil CO 2 flux (F CO2 ) obtained with a 16-chamber system at Lincoln, Nebraska in February 2006.<br />

Also shown are the soil temperature data for each chamber.


8100-101 Long-Term<br />

Chamber<br />

Motor-Driven<br />

Strut<br />

Novel Pressure<br />

Vent Design<br />

Adjustable<br />

Legs<br />

Double Gasket<br />

Seal<br />

Weatherproof<br />

Connectors<br />

The Long-Term Chamber<br />

■ 20 cm diameter<br />

■ Chamber pressure tracks<br />

ambient pressure<br />

■ Can be deployed on uneven<br />

surfaces and slopes<br />

■ Double gasket seal<br />

■ Mechanical movement<br />

minimizes soil perturbations<br />

■ –20 to 45°C operating<br />

temperature range


www.licor.com/8100<br />

The Multiplexed <strong>LI</strong>-8100 System<br />

The <strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

Designed exclusively for use with the <strong>LI</strong>-8100<br />

Automated Soil CO 2 Flux System, the <strong>LI</strong>-<strong>8150</strong><br />

<strong>Multiplexer</strong> allows up to 16 chambers to be<br />

connected.<br />

■ Choose from 8 or 16 port configurations<br />

■ Durable, weatherproof connectors and case<br />

■ High flow, low power, long-life solenoid<br />

valves<br />

■ Filter assemblies clean incoming air<br />

■ LED indicator panel provides<br />

<strong>Multiplexer</strong> diagnostic information<br />

■ System software for leak testing without<br />

the need for additional hardware<br />

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong> (left), four long-term chambers (background), <strong>LI</strong>-8100 Analyzer<br />

Control Unit (right), communication through wireless Palm ® PDA.<br />

System Advantages<br />

As your research needs grow, so can the <strong>LI</strong>-8100<br />

system. Its modular design allows for additional<br />

chambers to be added at any time. The pictures<br />

at right demonstrate the spatial flexibility of the<br />

system. The four chamber system is arranged in a<br />

square formation. With the addition of four more<br />

chambers, spatial coverage is doubled.<br />

Placement of chambers is flexible to within 15<br />

meters of the <strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong>. An 8-port<br />

<strong>LI</strong>-<strong>8150</strong> can easily be upgraded to 16 ports with a<br />

factory upgrade, or a field upgrade kit.<br />

Four chamber system<br />

Regardless of the number of chambers you use, the<br />

<strong>LI</strong>-8100 ACU has plenty of data storage capacity.<br />

Data can be stored on the instrument’s internal flash<br />

memory or on a removable compact flash card.<br />

Auxiliary sensors, such as soil temperature and<br />

moisture probes, can be connected at each chamber.<br />

Eight chamber system<br />

The <strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong> can be used for CO 2 profiling studies. Contact <strong>LI</strong>-COR for more details.


Ordering<br />

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong>. Choose from two versions:<br />

<strong>LI</strong>-<strong>8150</strong>-8 (eight ports) and <strong>LI</strong>-<strong>8150</strong>-16 (sixteen ports).<br />

<strong>LI</strong>-<strong>8150</strong>-8 Eight Port <strong>Multiplexer</strong>. Connect up to eight<br />

8100-101 Long-Term Chambers or gas sampling lines.<br />

Includes Spares Kit and Cable/Hose Assembly for<br />

connection to <strong>LI</strong>-8100 Analyzer Control Unit. <strong>LI</strong>-8100,<br />

Chambers, and Power Supply not included. (Note:<br />

<strong>LI</strong>-<strong>8150</strong> powers the <strong>LI</strong>-8100 Analyzer Control Unit<br />

when connected.)<br />

<strong>LI</strong>-<strong>8150</strong>-16 Sixteen Port <strong>Multiplexer</strong>. Connect up to<br />

sixteen 8100-101 Long-Term Chambers or gas<br />

sampling lines. Includes Spares Kit and Cable/Hose<br />

Assembly for connection to <strong>LI</strong>-8100 Analyzer Control<br />

Unit. <strong>LI</strong>-8100, Chambers, and Power Supply not<br />

included. (Note: <strong>LI</strong>-<strong>8150</strong> powers the <strong>LI</strong>-8100 Analyzer<br />

Control Unit when connected.)<br />

Accessories<br />

<strong>8150</strong>-706 DC Power Cable. 3 m cable, bare lead<br />

termination. For user-supplied DC power source.<br />

<strong>8150</strong>-770 AC Power Supply. Includes connection to<br />

<strong>LI</strong>-<strong>8150</strong>.<br />

<strong>8150</strong>-661 Chamber Interface Box. Required for each<br />

multiplexed 8100-101 Long-Term Chamber where<br />

auxiliary sensors are to be connected. Allows for<br />

connection of up to three auxiliary sensors.<br />

<strong>8150</strong>-705 Cable/Hose Extension Assembly. 15 meters<br />

in length. Use only one extension per chamber.<br />

8100-202 Soil Moisture Probe. (ECH 2 O) Volumetric<br />

water content, 0 to saturation.<br />

8100-203 Soil Temperature Thermistor. For use with<br />

multiplexed 8100-101 Long-Term Chambers.<br />

<strong>8150</strong>-916 Eight to Sixteen Port Upgrade. Upgrade an<br />

eight port <strong>Multiplexer</strong> to sixteen ports. Includes factory<br />

installation.<br />

<strong>LI</strong>-<strong>8150</strong> Specifications *<br />

<strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong><br />

Dimensions: 40.6 cm L x 57.2 cm W x 21.1 cm H<br />

(16” x 22.5” x 8.3”)<br />

Weatherproof Rating: Tested to IEC IP55 standard<br />

Weight<br />

8 port version: 9.4 kg (20.7 lb)<br />

16 port version: 11.2 kg (24.8 lb)<br />

Operating Range<br />

Temperature: –20 to 45 °C<br />

Humidity: 0 to 95% RH, non-condensing<br />

Coverage Area<br />

Max radius from <strong>LI</strong>-<strong>8150</strong> to chambers: 15.0 m (49.2 ft)<br />

Max diameter of measurement circle: 30.0 m (98.4 ft)<br />

Plumbing<br />

Flow rate to/from chambers: 2-5 lpm<br />

(user adjustable)<br />

Flow rate between <strong>LI</strong>-8100 and <strong>LI</strong>-<strong>8150</strong>: 1.7 lpm<br />

Pump in the <strong>LI</strong>-8100 sub-samples air stream in<br />

the <strong>LI</strong>-<strong>8150</strong><br />

<strong>LI</strong>-<strong>8150</strong> Pump Type: Rotary-vane (non-pulsating flow)<br />

Display<br />

Four LED Indicators: Power, Check Error Log, Manual<br />

Chamber Activation Indicator, Active Chamber Error<br />

Five 7-segment LED Displays: Active Chamber,<br />

Active Valve, three voltage channel indicators<br />

Power Requirements:<br />

10.5 – 14.5 VDC (120 VAC and 240 VAC with optional<br />

power supply)<br />

Power supplied through the <strong>LI</strong>-<strong>8150</strong>; <strong>LI</strong>-<strong>8150</strong> powers<br />

the <strong>LI</strong>-8100 when connected<br />

See example below for total system power requirements<br />

<strong>LI</strong>-8100 + <strong>LI</strong>-<strong>8150</strong><br />

+ n Chambers<br />

n Chambers<br />

2<br />

4<br />

8<br />

16<br />

Typical<br />

Operation<br />

Amps @<br />

12.5VDC<br />

Watts<br />

2.0<br />

2.1<br />

2.1<br />

2.3<br />

25<br />

26<br />

27<br />

29<br />

At Startup (IRGAs<br />

warming, chambers<br />

actuated)<br />

Amps @<br />

12.5VDC<br />

Watts<br />

2.0<br />

2.2<br />

2.3<br />

2.5<br />

25<br />

28<br />

29<br />

31<br />

*Specifications subject to change without notice.<br />

Long-Term Chamber<br />

System Volume: 4092.5 cm 3<br />

Soil Area Exposed: 317.8 cm 2 (49.3 in. 2 )<br />

Dimensions: 43.2 cm L x 38.1 cm W x 20.3 cm H<br />

(17" x 15" x 8")<br />

Air temperature thermistor<br />

Operating Range: –20 to 45 °C<br />

Accuracy (when connected to <strong>LI</strong>-<strong>8150</strong> <strong>Multiplexer</strong>):<br />

± 0.5 °C over 0 to 50 °C<br />

± 1.0 °C over –20 to 0 °C<br />

Accuracy (when connected to <strong>LI</strong>-8100 ACU):<br />

± 0.5 °C over 0 to 70 °C<br />

Cable length: 2 m (6.56 ft.)<br />

Weight: 5.9 kg (13 lb.)<br />

Chamber Sensor Interface<br />

Dimensions: 10.2 cm L x 3.8 cm W x 6.4 cm H<br />

(4" x 1.5" x 2.5")<br />

Inputs:<br />

3 general input channels (0-5 VDC)<br />

1 dedicated channel for soil moisture probe<br />

0-5V, powered every 1 to 60 minutes, user-selectable<br />

Power supply (external or from <strong>LI</strong>-<strong>8150</strong>):<br />

Constant or switched: 0-5 VDC<br />

Unregulated: 12 VDC (12-13.5 VDC typically)<br />

Connections: Terminal strip with screw posts<br />

Accessories<br />

Soil temperature thermistor<br />

6 foot cable. Accuracy: ± 1.0 °C from –20 to 50 °C<br />

Cable/hose extension assembly<br />

Length: 15 m<br />

Connections:<br />

Electrical cables:Turck weatherproof connectors<br />

Air hoses: Quick-connect fittings<br />

<strong>8150</strong>-916-1 Eight to Sixteen Port Field Upgrade Kit.<br />

Field installation kit includes control panel assembly,<br />

solenoid/valve bank assemblies, <strong>Multiplexer</strong> module<br />

PCA boards, filter assemblies, necessary hardware,<br />

and upgrade instruction document.<br />

4421 Superior Street • P.O. Box 4425 • Lincoln, Nebraska 68504 USA<br />

North America: 800-447-3576 • International: 402-467-3576 • FAX: 402-467-2819<br />

envsales@licor.com • envsupport@licor.com • www.licor.com<br />

In Germany, Norway, and the United Kingdom - <strong>LI</strong>-COR GmbH: +49 (0) 6172 17 17 771<br />

envsales-gmbh@licor.com • envsupport-gmbh@licor.com<br />

<strong>LI</strong>-COR is a registered trademark of <strong>LI</strong>-COR, Inc. All trademarks belong to their respective owners.<br />

These third parties do not endorse, are not affiliated with, and do not sponsor the <strong>LI</strong>-<strong>8150</strong> or other <strong>LI</strong>-COR<br />

products. Copyright 2006, <strong>LI</strong>-COR, Inc. Printed in the U.S.A. The <strong>LI</strong>-8100 is covered by U.S. Patents Pending<br />

and foreign equivalents.<br />

The <strong>LI</strong>-COR board of directors would like to take this<br />

opportunity to return thanks to God for His merciful<br />

providence in allowing <strong>LI</strong>-COR to develop and commercialize<br />

products, through the collective effort of<br />

dedicated employees, that enable the examination of<br />

the wonders of His works.<br />

“Trust in the LORD with all your heart and do not lean<br />

on your own understanding. In all your ways acknowledge<br />

Him, and He will make your paths straight.”<br />

—Proverbs 3:5,6<br />

05/06 980-08518

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!