Broadband Power - KABELKON
Broadband Power - KABELKON
Broadband Power - KABELKON
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
AlphaNet EDH-A2<br />
External DOCSIS ® Transponder<br />
> Add DOCSIS Status Monitoring capability<br />
to existing power supplies<br />
> Supports standard networking interfaces including<br />
SNMP, Web access and ANSI/SCTE MIBs<br />
> Multiple power supply models supported<br />
> Embedded Web server for remote diagnostics<br />
AlphaNet EDH-A2<br />
22<br />
Status Monitoring<br />
AlphaNet EDH-A2<br />
Specifications<br />
<strong>Power</strong> Supplies Supported:<br />
XP-EDH-A2<br />
XM2-HP, XM2 (requires USM2 or USM2.5 card)<br />
XM (requires APM/USM), AM (requires RPM card)<br />
Lectro ZTT, ZTT+ and CPR<br />
DOCSIS Compatibility: DOCSIS 1.1, 2.0<br />
Monitoring Protocol: SNMPv1<br />
Devices Monitored: <strong>Power</strong> supply, batteries 1<br />
Notes: 1 Reported as per ANSI/SCTE 25-3 2002 (HMS-022)<br />
RF Transmit/Receive<br />
Tx Frequency Range:<br />
Output <strong>Power</strong>:<br />
Channel Bandwidth:<br />
Receive Center<br />
Freq Range:<br />
Input Level:<br />
Monitored Parameters<br />
<strong>Power</strong> Supply Data<br />
Model:<br />
Major Alarm:<br />
Minor Alarm:<br />
5 to 42MHz<br />
8 to 55dBmV<br />
6MHz<br />
91 to 857MHz (Standard, HRC, IRC channels)<br />
-15 to 15dBmV<br />
XM2-HP/<br />
XM2<br />
XM<br />
AM<br />
ZTT<br />
Series<br />
Input Line Voltage Present: 1 1 1<br />
Output Voltage: 1<br />
Battery Voltage:<br />
Output Current: 1<br />
Standby/AC Line Fail:<br />
Equipment/Test Fail: - -<br />
Enclosure Door Status:<br />
Remote Test Control:<br />
Notes: 1 Requires optional cable assembly<br />
Number of Battery Strings:<br />
Battery Data:<br />
Up to two 36V or 48V strings<br />
Individual battery voltages<br />
Battery compartment temperature<br />
CPR<br />
Hardware<br />
Dimensions<br />
H x W x D (in/mm):<br />
RF Cable Interface:<br />
Local/Craft Interface:<br />
1.3 x 8.6 x 5.2 / 33 x 218 x 132<br />
F-connector, female, 75Ohm<br />
USB<br />
Environment<br />
Operating Temperature: -40 to 65°C / -40 to 149°F<br />
Humidity:<br />
10 to 90% non-condensing<br />
Emissions:<br />
Immunity:<br />
Management<br />
NMS/EMS:<br />
HMS MIBs:<br />
EN55022 Class A and FCC Part 15 Class A<br />
(Installed in power supply enclosure system)<br />
Surge Test per Specification (IEEE C62.41-1991)<br />
ESD Protection: ±8kV air discharge, ±6kV<br />
contact discharge as per (IEC 61000-4-2)<br />
Standard SNMP Management Tools<br />
In addition to the standard DOCSIS MIBs, the<br />
transponder supports the following HMS MIBs:<br />
• SCTE 25-3 (HMS-022): - Interface<br />
• SCTE 36 (HMS-050): - Root<br />
• MIB SCTE 37 (HMS-072): - Tree<br />
• MIB SCTE 38-1 (HMS-026): - Property<br />
• MIB SCTE 38-2 (HMS-023): - Alarm MIB<br />
• SCTE 38-3 (HMS-024): - Common<br />
• MIB SCTE 38-4 (HMS-027): - <strong>Power</strong> Supply<br />
• MIB SCTE 38-7 (HMS-050): - TIB MIB